Installing the Real Time Clock (RTC)/RAM Backup Battery  

CAUTION: 

When handling the Real Time Clock (RTC)/RAM Backup Battery, be 
careful NOT to touch the Positive and Negative Poles 
simultaneously.  Doing so will discharge the Battery.   

The Battery Holder is located on the left-

hand side of the Controller’s Printed Circuit 

Board (PCB), alongside the RTE Input Terminal Block (see Figure 5)

First Time Use 

1.  Remove the Controller

’s Top Cover. 

2.  Slide the supplied 3 V, CR2032, Lithium cell Battery under the metal clip of the 

Battery Holder, with the "+" Terminal facing UP. 

3.  Press the Battery firmly into the Battery Holder. 

4.  Attach the Controller

’s Top Cover. 

Replacement 

1.  Remove the Controller

’s Top Cover. 

2.  Remove the old 3 V, CR2032, Lithium cell Battery from the Battery Holder by 

pulling the plastic retaining clip horizontally AWAY from the Battery Holder.  The 
Battery Holder is spring-loaded, and will raise the Battery out of the Holder. 

3.  Slide the new 3 V, CR2032, Lithium cell Battery under the metal clip of the Battery 

Holder, with the "+" Terminal facing UP. 

4.  Press the new Battery firmly into the Battery Holder. 

5.  Attach the Controller

’s Top Cover. 

ELECTRICAL CONNECTIONS 

Controller Layout 

 

Figure 5:  Key Component Positions 

Summary of Contents for IXP110

Page 1: ...sing a Sealed Lead Acid Backup Battery and or Strike Lock 9 V AC to 18 V AC 9 V DC to 24 V DC NOTE Battery Charging Voltage and Power Output Voltage are set at between 13 6 V DC and 13 8 V DC NOTE Thi...

Page 2: ...ng Input protection to 50 V DC continuous Figure 1 End of Line EOL Sensing Circuit NOTE These Inputs can be individually configured to have End of Line EOL Sensing in the Software via the Communicatio...

Page 3: ...stors 25 Vrms 500 A 77 V max clamping Four Wood Screws 3 5 mm x 25 mm Four Wall Plugs 7 mm IXP905 1 0 GB XX includes a standard 2 m 7 ft USB Printer Cable The USB Cable will have a Type A plug fitted...

Page 4: ...area of the cable must not be less than 0 2 mm 2 0 0003 in 2 NOTE When installing an ImproX RA use 1 pair twisted cable Cable Specifications The cable specifications should be similar to the following...

Page 5: ...gs supplied nuts and bolts or rivets Top Cover Release Mechanism 1 Remove the top two Thread Cutter Screws 2 2 x 5 mm from each of the End Plates 2 Insert a flat head screwdriver maximum 7 mm into the...

Page 6: ...r the metal clip of the Battery Holder with the Terminal facing UP 3 Press the Battery firmly into the Battery Holder 4 Attach the Controller s Top Cover Replacement 1 Remove the Controller s Top Cove...

Page 7: ...IXP343 0 0 GB 07 April 2009 Page 7 Connecting the IXP110 Controller Figure 6 Input and Power Connections...

Page 8: ...IXP343 0 0 GB 07 April 2009 Page 8 Figure 7 Antenna Reader and Relay Connections...

Page 9: ...s necessary to clear all Tagholders including all Tagholder settings follow these steps Figure 8 Deleting the Database Restore Factory Defaults If it becomes necessary to return the IXP110 System to i...

Page 10: ...ns including deleting the database and restoring factory defaults MAC Address The MAC Address identifies the Lantronix XPort component placed in each Ethernet version of the IXP110 Controller IXP906 1...

Page 11: ...IXP343 0 0 GB 07 April 2009 Page 11 USER NOTES...

Page 12: ...mproX IXP110 Controller IXP904 1 0 GB 02 IXP905 1 0 GB 02 and IXP906 1 0 GB 03 The last two digits of the Impro stock code indicate the issue status of the product IXP343 0 0 GB 07 Issue 08 Apr 2009 I...

Reviews: