background image

 

IXP343-0-0-GB-07 

 

April 2009 

Page 3 

 

Controller Interfaces 

 

 

Status LED .............................  

Green LED (externally visible). 

Antenna Reader Interfaces 

 

 

Status Indicator 

 

 

Status LED .....................  

Bi-colour, Red or Green LED. 

 

Buzzer 

 

 

Volume and Tone ...........  

4-Step adjustable volume, single tone. 

INSTALLATION INFORMATION 

Accessories 

Find the following when unpacking the ImproX IXP110 Controller: 

 

An IXP110 Controller housed in a Black, Aluminium extruded Cabinet.  The 
Cabinet consists of a Top Cover, a Base and two End Plates.  Each End Plate is 
attached with four Thread Cutter Screws (2.2 x 5 mm).  

 

One copy of IXP110 Software on CD. 

 

A 3 V Lithium Battery (CR2032). 

CAUTION: 

DO NOT use the Metal-oxide Varistors (25 Vrms, 500 A, 77 V max 
clamping) with mains power applications. 

 

Two Metal-Oxide Varistors, 25 Vrms, 500 A, 77 V max clamping. 

 

Four Wood Screws (3.5 mm x 25 mm). 

 

Four Wall Plugs (7 mm). 

 

IXP905-1-0-GB-XX includes a standard 2 m (7 ft) USB Printer Cable.  The USB 
Cable will have a 

Type ‘A’ plug fitted at one end and a Type ‘B’ plug fitted at the 

other end. 

 

IXP906-1-0-GB-XX includes a MAC Address Label. 

 

An extra Fixed Address Label. 

General 

Remember the following when installing your IXP110 Controller: 

Communications Distance 

 

The Ethernet version of the Controller plugs into an Ethernet Switch or Hub (or 
other network device), cable runs for this must conform to ethernet cabling 
specifications. 

 

The RS232 communications distance between the IXP110 Controller and the 
connected Host PC MUST NOT exceed 25 m (82 ft).  Achieve this by using good 
quality screened 4-core cable. 

 

The USB communications distance between the Host PC and the IXP110 
Controller MUST NOT exceed 5 m (16 ft).  Please note, however, the SUPPLIED 
CABLE CANNOT BE EXTENDED. 

 

Summary of Contents for IXP110

Page 1: ...sing a Sealed Lead Acid Backup Battery and or Strike Lock 9 V AC to 18 V AC 9 V DC to 24 V DC NOTE Battery Charging Voltage and Power Output Voltage are set at between 13 6 V DC and 13 8 V DC NOTE Thi...

Page 2: ...ng Input protection to 50 V DC continuous Figure 1 End of Line EOL Sensing Circuit NOTE These Inputs can be individually configured to have End of Line EOL Sensing in the Software via the Communicatio...

Page 3: ...stors 25 Vrms 500 A 77 V max clamping Four Wood Screws 3 5 mm x 25 mm Four Wall Plugs 7 mm IXP905 1 0 GB XX includes a standard 2 m 7 ft USB Printer Cable The USB Cable will have a Type A plug fitted...

Page 4: ...area of the cable must not be less than 0 2 mm 2 0 0003 in 2 NOTE When installing an ImproX RA use 1 pair twisted cable Cable Specifications The cable specifications should be similar to the following...

Page 5: ...gs supplied nuts and bolts or rivets Top Cover Release Mechanism 1 Remove the top two Thread Cutter Screws 2 2 x 5 mm from each of the End Plates 2 Insert a flat head screwdriver maximum 7 mm into the...

Page 6: ...r the metal clip of the Battery Holder with the Terminal facing UP 3 Press the Battery firmly into the Battery Holder 4 Attach the Controller s Top Cover Replacement 1 Remove the Controller s Top Cove...

Page 7: ...IXP343 0 0 GB 07 April 2009 Page 7 Connecting the IXP110 Controller Figure 6 Input and Power Connections...

Page 8: ...IXP343 0 0 GB 07 April 2009 Page 8 Figure 7 Antenna Reader and Relay Connections...

Page 9: ...s necessary to clear all Tagholders including all Tagholder settings follow these steps Figure 8 Deleting the Database Restore Factory Defaults If it becomes necessary to return the IXP110 System to i...

Page 10: ...ns including deleting the database and restoring factory defaults MAC Address The MAC Address identifies the Lantronix XPort component placed in each Ethernet version of the IXP110 Controller IXP906 1...

Page 11: ...IXP343 0 0 GB 07 April 2009 Page 11 USER NOTES...

Page 12: ...mproX IXP110 Controller IXP904 1 0 GB 02 IXP905 1 0 GB 02 and IXP906 1 0 GB 03 The last two digits of the Impro stock code indicate the issue status of the product IXP343 0 0 GB 07 Issue 08 Apr 2009 I...