background image

 

SGI300-0-0-GB-08 

April 2008 

Page 15 

 

USER NOTES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for IMPROX SUPAGATE SGI911-1-1-GB-XX

Page 1: ...cy 433 92 MHz Security ImproX DCT Dynamic Code Transmission Technology Input Voltage 10 V DC to 14 V DC Power Requirements Current mA Power W Input Voltage 12 V DC 1 Antenna Reader all Relays OFF 60 0...

Page 2: ...yd to 33 yd when used with the ImproX QT XQT904 1 1 GB XX The passive read range varies from between 25 mm to 76 mm 1 in to 3 in depending on the Antenna Reader and Tag used Antenna Reader Distance Th...

Page 3: ...1 drives Relay 1 Relay 1 Relay 2 Relay 3 Relay 4 Quad Transmitter Button 1 Button 2 Button 3 Button 4 Passive Tag Antenna Reader 1 4 Digit PIN code Antenna Reader 1 5 Digit PIN code Antenna Reader 1 P...

Page 4: ...the supplied standoffs to position the SupaGate away from the wall NOTE Test the SupaGate in the proposed installation location before mounting in position ensuring the read range meets your needs For...

Page 5: ...tion the SupaGate in clear line of sight preferably 1 50 m to 2 m 5 ft to 6 ft above the ground in the direction of movement with the Antenna vertical 3 Secure the Cabinet to the mounting surface usin...

Page 6: ...SGI300 0 0 GB 08 April 2008 Page 6 Figure 5 shows a typical connection diagram for the SupaGate Figure 5 Typical SupaGate Electrical Connections...

Page 7: ...ive Tags 1 In Run Mode press the ADD Push button for less than 1 second 2 Press the TENS and UNITS Push buttons until the desired Tag Location is shown 3 Present the Passive Tag to the Antenna Reader...

Page 8: ...he Tag already exists it will be deleted and re added in the same location 1 second Displays the first free Location 01 99 2 seconds Displays the Button Number as follows Adding Normal 4 Digit PIN cod...

Page 9: ...nna Reader to complete the entry 4 Press ADD to return to Run Mode NOTE Ensure you enter the complete 5 digit code followed by the Key to gain entry 1 second Displays the first free Location 01 99 2 s...

Page 10: ...nds 01 99 seconds 1 Press the ADD Push button for less than 1 second 2 Press the TENS and UNITS Push buttons to specify the duration of Relay 2 in seconds 00 Toggled Mode NOTE The factory default sett...

Page 11: ...opriate Relay durations need to be chosen If the incorrect PIN code is entered 3 times in succession the Keypad locks for 20 seconds During this period the RF System remains operational If you select...

Page 12: ...te using Table 2 This list provides an easy reference when you need to delete Tags from the SupaGate Owner Relay or PIN code Owner Relay or PIN code 1 2 3 4 5 R 1 2 3 4 5 R 01 27 02 28 03 29 04 30 05...

Page 13: ...lay or PIN code Owner Relay or PIN code 1 2 3 4 5 R 1 2 3 4 5 R 53 77 54 78 55 79 56 80 57 81 58 82 59 83 60 84 61 85 62 86 63 87 64 88 65 89 66 90 67 91 68 92 69 93 70 94 71 95 72 96 73 97 74 98 75 9...

Page 14: ...We reserve the right to nullify the products guarantee or warranty where you have not properly installed the Metal oxide Varistors This product conforms to our Guarantee or Warranty details placed on...

Page 15: ...SGI300 0 0 GB 08 April 2008 Page 15 USER NOTES...

Page 16: ...plicable to the ImproX SupaGate 4 Channel Controller SGI911 1 1 GB 01 The last two digits of the stock code indicate the issue status of the product SGI300 0 0 GB 08 Issue 09 Apr 2008 ImproX SupaGate...

Reviews: