CHEETAH Hardware User’s Manual
Imperx, Inc.
Rev. 6.2
6421 Congress Ave.
7/7/2015
Boca Raton, FL 33487
+1 (561) 989-0006
67 of 152
Figure 2.15c – OUT 1 LVTTL electrical connection.
D.
Output OUT 2 - Opto-isolated
Output OUT 2 is an optically isolated switch. There is no pull-up voltage on either
contact. The voltage across OUT 2 Contact 1 and OUT 2 Contact 2
MUST NOT
exceed 25 volts and the current through the switch
MUST NOT
exceed 50 mA.
Figure 2.15d: OUT 2 Opto-Isolated electrical connection
2.15
TEST IMAGE PATTERNS
2.15.1Test Image patterns
The camera can output several test images, which can be used to verify the camera’s
general performance and connectivity to the frame grabber. This ensures that all the
major modules in the hardware are working properly and that the connection
between the frame grabber and the camera is synchronized – i.e., the image framing,
output mode, communication rate, etc. are properly configured. Please note that the
test image patterns do not exercise and verify the image sensor functionality.