Adapt-A-Link
Manual
Imperx Inc.
Adapt-A-Link Manual
6421 Congress Ave.
Rev 1.0
Boca Raton, FL 33487
01.14.05
46
PIN
Camera Link Signal
Si
e
gnal Nam
1
Inner Shield
Inner Shield
14
Inner Shield
Inner Shield
25
- Y 0
- PAIR 1
12
+ Y 0
+ PAIR 1
24
- Y 1
- PAIR 2
11
+ Y 1
+ PAIR 2
23
- Y 2
- PAIR 3
10
+ Y 2
+ PAIR 3
22
- Y CLK
- PAIR 4
9
+ Y CLK
+ PAIR 4
21
- Y 3
- PAIR 5
8
+ Y 3
+ PAIR 5
20
N/C
+ PAIR 6
7
N/C
- PAIR 6
19
N/C
- PAIR 7
6
N/C
+ PAIR 7
18
N/C
- PAIR 8
5
N/C
+ PAIR 8
17
N/C
+ PAIR 9
4
N/C
- PAIR 9
16
N/C
- PAIR 10
3
N/C
+ PAIR 10
15
N/C
+ PAIR 11
2
N/C
- PAIR 11
13
Inner Shield
Inner Shield
26
Inner Shield
Inner Shield
SIGNA
Hz.
4.
5.
ng to the camera (Ser TC)
7.
ace
can be switched from RS232 (default) to SERIAL DATA with a set of jumpers located
r to October 1, 2004 do not support RS232 interface.
two or
Table 21b. Pin assignments for the second (Medium) 26 pins input connector.
L INFORMATION
1. DATA (0 – 47) – 48 bit actual data.
2. PIXEL CLOCK - Reference camera clock (X CLK). Maximum frequency is 66 M
3. SERIAL DATA IN - Serial communications signal going to the camera (Ser TC).
SERIAL DATA OUT - Serial communications signal going to the frame grabber (Ser
TFG). SERIAL DATA IN/OUT are 3.3V LVTTL level signals.
RS232 Rx - Serial communications signal goi
6. RS232 Tx - Serial communications signal going to the frame grabber (Ser TFG).
RS232 Tx/Rx and SERIAL DATA IN/OUT are mutually exclusive. The serial interf
inside the box.
Units sold prio
Please contact Imperx for more information.
8. 6.0 VDC OUT - Provides power (if needed) for the next Adapt-A-Link unit, if
more adapter units are used in the same chain. Each unit can provide 1000 mA MAX.
9. 6.0 VDC GROUND - Ground return from the next Adapt-A-Link unit in the chain.
10. N/C – not used, not connected