Adapt-A-Link
Manual
Imperx Inc.
Adapt-A-Link Manual
6421 Congress Ave.
Rev 1.0
Boca Raton, FL 33487
01.14.05
60
PIN
Camera
Signal
Link
Si
e
gnal Nam
1
Inner Shield
Inner Shield
14
Inner Shield
Inner Shield
25
- Y 0
- PAIR 1
12
+ Y 0
+ PAIR 1
24
- Y 1
- PAIR 2
11
+ Y 1
+ PAIR 2
23
- Y 2
- PAIR 3
10
+ Y 2
+ PAIR 3
22
- Y CLK
- PAIR 4
9
+ Y CLK
+ PAIR 4
21
- Y 3
- PAIR 5
8
+ Y 3
+ PAIR 5
20
N/C
+ PAIR 6
7
N/C
- PAIR 6
19
N/C
- PAIR 7
6
N/C
+ PAIR 7
18
N/C
- PAIR 8
5
N/C
+ PAIR 8
17
N/C
+ PAIR 9
4
N/C
- PAIR 9
16
N/C
- PAIR 10
3
N/C
+ PAIR 10
15
N/C
+ PAIR 11
2
N/C
- PAIR 11
13
Inner Shield
Inner Shield
26
Inner Shield
Inner Shield
SIG
ata.
z.
4. SERIAL DATA OUT - Serial communications signal going to the frame grabber (Ser
the same chain. Each unit can provide 1000 mA MAX.
e next Adapt-A-Link unit in the chain.
10. N/C – not used, not conne
Table 27b. Pin assignments for the second (Medium) 26 pins input connector.
NAL INFORMATION
1. DATA (0 – 47) – 48 bit actual d
2. PIXEL CLOCK - Reference camera clock (X CLK). Maximum frequency is 66 MH
3. SERIAL DATA IN - Serial communications signal going to the camera (Ser TC).
TFG). SERIAL DATA IN/OUT are 3.3V LVTTL level signals.
5. RS232 Rx - Serial communications signal going to the camera (Ser TC)
6. RS232 Tx - Serial communications signal going to the frame grabber (Ser TFG).
7. RS232 Tx/Rx and SERIAL DATA IN/OUT are mutually exclusive. The serial interface
can be switched from RS232 (default) to SERIAL DATA with a set of jumpers located
inside the box.
Units sold prior to October 1, 2004 do not support RS232 interface.
Please contact Imperx for more information.
8. 6.0 VDC OUT - Provides power (if needed) for the next Adapt-A-Link unit, if two or
more adapter units are used in
9. 6.0 VDC GROUND - Ground return from th
cted