Impax IM-MMA140 Instruction Manual Download Page 20

19

ENVIRONMENTAL PROTECTION & SYMBOLS

Information for (private householders) for the environmentally responsible disposal of Waste
Electrical and Electronic Equipment (WEEE)

This symbol on products and or accompanying documents indicates that used 
and end of life electrical and electronic equipment should not be disposed of in 
household waste. For the proper disposal, treatment, recovery and recycling, 
please take these products to designated collection points, where they will be 
accepted on a free of charge basis. Alternatively, in some countries you may be 
able to return your products to your retailer upon the purchase of an equivalent 
new product. Disposing of this product correctly will help to save valuable 
resources and prevent any potential adverse effects on human health and the 

environment which could otherwise arise from inappropriate waste disposal and handling. Please
contact your local authority for further details of your nearest designated collection point. Penalties
may be applicable for incorrect disposal of this waste in accordance with national legislation.

FOR BUSINESS USERS IN THE EUROPEAN UNION.

If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for
further information.

Information on Disposal in other Countries outside the European Union.

This Symbol is only valid in the European Union.
If you wish to dispose of this product, please contact your local authorities or dealer and ask for the
correct method of disposal.

The rating plate on this product may show symbols. These represent important information about the
product or instructions on its use.

Conforms to relevant safety 
standards.

Read the instruction manual.

Product conforms to RoHs
requirements

Waste electrical products
should not be disposed of
with household waste. Please
recycle where facilities exist.
Check with your Local
Authority or retailer for
recycling advice

Warning! Electrical welding
process

uV

Protect operator and passer
bye from the effect of uV
radiation. This can cause
permanant damage to the
eye. Make sure the arc and
resulting flash is shielded at
all times.

Always wear approved face
mask with correct filter,
gloves and apron to protect
against welding operation

Do not use this welder in
damp conditions

Keep bystanders and pets
clear of the welding power
supply when in use. 

Summary of Contents for IM-MMA140

Page 1: ...cumentation holder The technical documentation required to demonstrate that the product meets the requirements of directive has been compiled and is available for inspection by the relevant enforcemen...

Page 2: ...Always Read Instruction Manual Retain for Future Reference IM MMA140 140A MMA WELDER...

Page 3: ...adequately packed to prevent transit damage and must be accompanied with a brief description of the fault and a copy of the receipt or other proof of purchase The manufacturer shall not be liable for...

Page 4: ...e cables above below and adjacent to the welding equipment b radio and television transmitters and receivers c computer and other control equipment d safety critical equipment e g guarding of industri...

Page 5: ...ent With Output On Off Control Contactor Welding power sources for use with the gas metal arc welding gas tungsten arc welding and similar processes normally are equipped with devices that permit on o...

Page 6: ...ned space only while it is being ventilated and if necessary while wearing an air supplied respirator Vapours from chlorinated solvents can be decomposed by the heat of the arc or flame to form PHOSGE...

Page 7: ...ombustibles at least 10M away out of reach of sparks and heat or protect against ignition with suitable and snug fitting fire resistant covers or shields Walls ceilings and floor near work should be p...

Page 8: ...ses danger of explosion or on materials cleaned with chlorinated solvents or on varnished surfaces danger of toxic fumes Remove all flammable materials from the work area Ensure there is adequate fire...

Page 9: ...ate sparks which may ignite the dust or fumes c Keep children and bystanders away while operating a power tool Distractions can cause you to lose control 2 Electrical Safety a Power tool plugs must ma...

Page 10: ...tools Such preventive safety measures reduce the risk of starting the power tool accidentally d Store idle power tools out of the reach of children and do not allow persons unfamiliar with the power...

Page 11: ...acement fuse covers can be obtained from your local dealer or most electrical stockists Fuse Rating The fuse in the plug must be replaced with one of the same rating 13 amps and this replacement must...

Page 12: ...cator 13 Earth clamp attachment point 14 Electrode holder attachment point Technical specification Input power 230 240V 50Hz Phase 1 Rated input current 19 5A Fuse 16A Rated no load voltage 85V DC Rat...

Page 13: ...sk To assemble the mask bend in the top and side flaps Fig 1 and clip into place then attach the handle and mask glass shield as shown in Fig 2 Insert the clear glass panel first followed by the dark...

Page 14: ...LITY OF ANY WELDED JOINT IS DEPENDANT ONTHE PREPARATION OFTHE JOINTTHE SELECTION OFTHE CORRECT ELECTRODE ANDTHE SKILL AND EXPERIENCE OFTHE WELDER Ensure the Welding Power Supply is disconnected from t...

Page 15: ...piece must be 20 30 Fig 9 Do not hit the electrode on the workpiece as this may damage the electrode Withdraw with a clean movement at the end of the welding run Note This is the most difficult aspect...

Page 16: ...hipped off the weld bead once the weld run is complete or before the next weld pass is deposited The process allows only short lengths of weld to be produced before a new electrode needs to be inserte...

Page 17: ...s high as 130 to 140 can be achieved for rutile and basic electrodes without marked deterioration of the arcing characteristics but the arc tends to be less forceful which reduces bead penetration Car...

Page 18: ...t circuits Periodically clean the inside of the welder with compressed air ensuring you wear a mask during the operation Important Always disconnect from the electrical supply before servicing or clea...

Page 19: ...n the weld area prior to welding Weld current interrupted Thermal trip has operated Allow the welder to cool down Porous weld Rusty or dirty joints Clean the weld area prior to welding Irregular weld...

Page 20: ...l legislation FOR BUSINESS USERS INTHE EUROPEAN UNION If you wish to discard electrical and electronic equipment please contact your dealer or supplier for further information Information on Disposal...

Page 21: ...des 50Hz Nominal mains frequency Diameter of electrodes U0 No load voltage A V to A V Range of output X Duty cycle I2 Conventional welding current U2 Conventional load voltage U1 Mains voltage I1 max...

Page 22: ...21 NOTES...