![IMO VXSM150-1 Instruction Manual Download Page 34](http://html.mh-extra.com/html/imo/vxsm150-1/vxsm150-1_instruction-manual_2048149034.webp)
Selecting Functions
5-5
5
Min.
Factory
Name
Setting range
unit
setting
C01
Jump frequency
(Jump freq. 1)
0 to 400Hz
1Hz
0
0
C02
(Jump freq. 2)
0
0
C03
(Jump freq. 3)
0
0
C04
(Hysteresis)
0 to 30Hz
1Hz
3
0
C05
Multistep frequency
setting (Freq. 1)
0.00 to 400.0Hz
0.01Hz
0.00
4
C06
(Freq. 2)
0.00
4
C07
(Freq. 3)
0.00
4
C08
(Freq. 4)
0.00
4
C09
(Freq. 5)
0.00
4
C10
(Freq. 6)
0.00
4
C11
(Freq. 7)
0.00
4
C12
(Freq. 8)
0.00
4
C13
(Freq. 9)
0.00
4
C14
(Freq. 10)
0.00
4
C15
(Freq. 11)
0.00
4
C16
(Freq. 12)
0.00
4
C17
(Freq. 13)
0.00
4
C18
(Freq. 14)
0.00
4
C19
(Freq. 15)
0.00
4
C21
Timer operation
0: Inactive
1
0
X
0
1: Active
C22
Stage 1
0.00 to 3600s
0.01s
0.00
6
C30
Frequency command 2
0 to 8 (Same as F01)
1
2
X
0
C31
Analog setting signal
-5.0 to +5.0%
0.1%
0.0
3
offset adjustment
(Terminal 12)
C32
(Terminal C1)
-5.0 to +5.0%
0.1%
0.0
3
C33
Analog setting
0.00 to 5.00s
0.01s
0.05
4
signal filter
Function code
Change during
operation
RS485 Data format
User setting
C: Control functions of frequency
Description of change during operation
: The data changed by the or key takes
effect on the inverter operation. However,
press the key to store the new data.
V
V
: Press the or key to change the data.
The new data takes effect after the key is
pressed to store the data.
X : The data can be changed only while the
inverter is stopped.
V
V
FUNC
DATA
FUNC
DATA
Summary of Contents for VXSM150-1
Page 3: ......
Page 41: ...5 12 Selecting Functions 5 Frequency setting block diagram ...
Page 45: ...5 16 Selecting Functions 5 Note The chain line indicates the motor speed ...
Page 71: ...7 1 Troubleshooting 7 7 Troubleshooting 7 1 When Protective Function Activates 1 Overcurrent ...