9-27
Specifications
9
(11)
Data format 11
16-bit binary code, least increment 0.01,
positive/negative data (5-byte ASCII code)
ASCII code
4-digit hexadecimal data
➾
4-digit ASCII code
(of minus sign
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Example: In the case that M09 (output frequency) = +60.00 Hz
60.00 ¥ 100 = 6000 (dec.) = 1770 (hex.), hence:
➾
Positive data is handled in a 4-byte ASCII code similarly to data format 0.
• In the case that M09 (output frequency) = -60.00 Hz
60.00 x 100 = 6000 (dec.) = 1770 (hex.). An ASCII code of the minus sign is added at the top.: -1770
➾
(12)
Data format 12
Data format for P04, A13 (auto tuning)
1
7
7
0
–
1
7
7
0
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
*
*
REV
FWD
Unused (fixed to “0”)
Unused (fixed to “0”)
Data field
Communication H30
setting
data
0 or 1
2 or 3
(P04 or A13)
Operation command
Keypad panel
Terminal block
RS485
0000H
ACK: However, no operation
ACK: However, no operation
NAK
0100H
NAK
NAK
ACK: However, no
operation
0200H
NAK
NAK
ACK: However, no
operation
0300H
NAK
NAK
NAK
0001H
NAK
Note 1
NAK
0101H
NAK
NAK
Note 2
0201H
NAK
NAK
Note 2
0301H
NAK
NAK
NAK
0002H
NAK
Note 1
NAK
0102H
NAK
NAK
Note 2
0202H
NAK
NAK
Note 2
0302H
NAK
NAK
NAK
Note 1: Tuning is started upon a terminal block
operation command. After tuning is completed,
an ACK response is given. (The ACK response
is given before the terminal block is turned off.)
Note 2: After data is written via RS485, tuning
is started. After tuning is completed, an ACK
response is given. (The operation command is
automatically turned off.)
Summary of Contents for VXSM150-1
Page 3: ......
Page 41: ...5 12 Selecting Functions 5 Frequency setting block diagram ...
Page 45: ...5 16 Selecting Functions 5 Note The chain line indicates the motor speed ...
Page 71: ...7 1 Troubleshooting 7 7 Troubleshooting 7 1 When Protective Function Activates 1 Overcurrent ...