37
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
3.20 TECHNICAL DATA.
- The data relevant to domestic hot water
performance refers to a dynamic inlet pressure
of 2 bar and an inlet temperature of 15°C; the
values are measured directly at the boiler outlet
considering that to obtain the data declared
mixing with cold water is necessary.
- * Yields refer to the net heating value.
Nominal heat input
kW (kcal/h)
32.6 (28042)
Minimum heat input
kW (kcal/h)
4.2 (3648)
Nominal heat output (useful)
kW (kcal/h)
32.0 (27520)
Minimum heat output (useful)
kW (kcal/h)
4.0 (3440)
*Efficiency 80/60 Nom./Min.
%
98.1 / 94.3
*Efficiency 50/30 Nom./Min.
%
106.5 / 105.3
*Efficiency 40/30 Nom./Min.
%
107.7 / 105.9
Heat loss at casing with burner On/Off (80-60°C)
%
0.47 / 0.30
Heat loss at flue with burner On/Off (80-60°C)
%
0.03 / 2.20
Central heating circuit max. operating pressure
bar
3
Central heating circuit max. operating temperature
°C
90
Adjustable central heating temperature (max work field)
°C
20 - 85
System expansion vessel total volume
l
5.8
Expansion vessel factory-set pressure
bar
1.0
Water content in generator
l
5.7
Head available with 1000 l/h flow rate
kPa (m H
2
O)
31.0 (3.16)
Hot water production useful heat output
kW (kcal/h)
32.0 (27520)
Domestic hot water adjustable temperature
°C
30 - 60
Min. pressure (dynamic) domestic hot water circuit
bar
0.3
Domestic hot water circuit max. working pressure
bar
10
Flow rate capacity in continuous duty (∆T 30°C)
l/min
16.1
Domestic hot water performance classification according to N 13203-1
Weight of full boiler
kg
51.6
Weight of empty boiler
kg
45.9
Electrical connection
V/Hz
230 / 50
Power input
A
0.78
Installed electric power
W
110
Pump consumption
W
70
EEI
-
≤ 0,20 - Part. 3
Fan power consumption
W
33
Equipment electrical system protection
-
IPX5D
Max temperature of combustion products
°C
75
Max. flue overheating temperature
°C
120
NO
X
class
-
6
Weighted NO
X
mg/kWh
26
Weighted CO
mg/kWh
12
Type of appliance
C13 / C13x / C33 / C33x / C43 / C43x / C53 / C63 /
C83 / C93 / C93x / B23p / B33
Category
II 2H3P
STD.002229/002
Summary of Contents for VICTRIX ZEUS SUPERIOR 32 2 ERP
Page 1: ...VICTRIX SUPERIOR 32 2 ERP Instruction and warning book IE 1 037985ENG STD 002229 002 ...
Page 2: ...STD 002229 002 ...
Page 44: ...44 STD 002229 002 ...
Page 45: ...45 STD 002229 002 ...
Page 46: ...46 STD 002229 002 ...
Page 47: ...47 STD 002229 002 ...