Flue terminal positions
Use as a guide only. Refer to AS/NZS 5601 or gas fitting rules for specific location.
D - Door
I - Mechanical air inlet
M - Gas meter
T - Flue Terminal
W - Window
Ref.
Item
Min. Clearance mm
a
Below eaves, balconies and other projections (Appliances over 50MJ/h)
300
b
From the ground, above a balcony or other surface
300
c
From a return wall or external wall
300
d
From a gas meter
1000
e
From an electricity meter or fusebox/breaker panel
500
f
From a drain pipe or soil pipe
75
g
Horizontally from any building structure or obstruction facing a flue terminal
500
h
From any other flue terminal, cowl or combustion air intake
300
j
Horizontally from any opening window, door, non-mechanical air inlet or other opening into a building with the exception of sub-floor ventilation
300
k
From a mechanical air inlet including a spa blower
1000
n
Vertically below an opening window, non-mechanical air inlet or any other opening into a building with the exception of sub-floor ventilation
500
• The location of the flue terminal must comply with the clea-
rances shown on this page.
If you are unsure about clearances not indicated here, in general
refer to AS 5601 or your local autority.
• All measurements are the minimum clearances required.
• Terminals must be positioned so to aviod combustion products
entering the building.
Flue terminal positions. Shaded area indicates prohibited area
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
1
BOILER
INSTALLATION
1.1 INSTALLATION
RECOMMENDATIONS.
Only professionally qualified heating/plumbing
technicians are authorised to install Immergas
gas appliances.
Victrix Pro 55 1A boilers in individual or cascade
installation can be installed outdoors or in a
suitable room.
The installation must comply with all laws and
standards in force.
The place of installation of the appliance and
relative Immergas accessories must have suitable
features (technical and structural) such to allow
(always in safety, efficiency and comfortable
conditions):
- installation (according to the provisions of the
technical legislation and technical regulations);
- maintenance operations (including scheduled,
periodic, routine and special maintenance);
- removal (to outdoors in the place for loading
and transporting the appliances and compo-
nents) as well as their eventual replacement
with appliances and/or equivalent components.
Installation must be carried out according to
regulation standards AS/NZS 5601 or Local
Authority laws
.
Attention:
these boilers must be used to heat
rooms and the like; they are for heating water
to a temperature lower than boiling point at
atmospheric pressure. Therefore, they must be
connected to a heating system that is suitable for
their performance and their power.
Attention:
Immergas declines all liability for
damages caused by boilers removed from other
systems or for any non-conformities of such
equipment.
Before installing the appliance, ensure that it is
delivered in perfect condition; if in doubt, contact
Hunt Heating immediately.
Packaging materials (staples, nails, plastic bags,
polystyrene foam, etc.) constitute a potential haz-
ard and must be kept out of the reach of children.
Keep all flammable objects away from the ap-
pliance (paper, rags, plastic, polystyrene, etc.).
In the event of malfunctions, faults or incorrect
operation, turn the appliance off and contact the
installer before contacting Hunt Heating.
Do not attempt to modify or repair the appli-
ance alone.
Failure to comply with the above implies personal
responsibility and invalidates the warranty.
-
Installations MUST comply with AS/NZS
5601 and Local laws. Use AS/NZS 5601 as a
guide for specific locations see below.
• Installation regulations: these boilers are not
in any way designed for installation on bases
or floors (Fig. 1-1), but exclusively for wall
installation. The wall surface must be smooth,
without any protrusions or recesses enabling
access to the rear part. Wall mounting of the
boiler must guarantee stable and efficient sup-
port for the boiler.
The plugs (standard supply)
are to be used only in conjunction with the
mounting brackets or fixing template to fix the
appliance to the wall;
they only ensure adequate
support if inserted correctly (according to
technical standards) in walls made of solid or
semi-hollow brick or block. In the case of walls
made from hollow brick or block, partitions
YES
NO
with limited static properties, or in any case
walls other than those indicated, a static test
must be carried out to ensure adequate support.
The boilers must be installed in a way to prevent
collisions and tampering.
N.B.: the hex head screws supplied in the bli-
ster pack are to be used exclusively to fix the
mounting bracket to the wall.
N.B.: it is recommended to use a suitable ‘Safe
Tray’, if boiler is installed in a loft, above a cei-
ling, or any area where damage can be caused
by water.