- The data relevant to domestic hot water perfor-
mance refer to a dynamic inlet pressure of 2 bar
and an inlet temperature of 15°C; the values are
measured directly at the boiler outlet consider-
ing that to obtain the data declared mixing with
cold water is necessary.
3.20 TECHNICAL DATA.
Maior Eolo 24
Maior Eolo 28
Maior Eolo 32
Nominal heat input
kW (kcal/h)
25.8 (22194)
29.7 (25536)
34.2 (29433)
DHW minimum heat input
kW (kcal/h)
8.1 (6968)
9.9 (8480)
12.2 (10524)
CH minimum heat input
kW (kcal/h)
10.6 (9094)
12.7 (10902)
14.8 (12710)
Nominal heat output (useful)
kW (kcal/h)
24.0 (20640)
28.0 (24080)
32.0 (27520)
DHW minimum heat output (useful)
kW (kcal/h)
7.0 (6020)
8.5 (7310)
10.5 (9030)
CH minimum heat output (useful)
kW (kcal/h)
9.3 (7998)
11.2 (9632)
12.9 (11087)
Efficiency at nominal heat output
%
93.0
94.3
93.5
Efficiency at 30% nominal heat output load
%
90.5
91.5
90.7
Heat loss at case with burner On/Off
%
0.50 / 0.75
0.00 / 0.53
0.70 / 0.50
Heat loss at flue with burner On/Off
%
6.0 / 0.02
5.70 / 0.06
5.80 / 0.04
Central heating circuit max. operating pressure
bar
3.0
3.0
3.0
Maximum heating temperature
°C
90
90
90
Adjustable central heating temperature
°C
35 - 85
35 -85
35 - 85
System expansion vessel total volume
l
8.0
7.4
7.4
Heating expansion vessel pre-charge
bar
1.0
1.0
1.0
Appliance water content
l
1.3
1.5
2.0
Head available with 1000 l/h flow rate
kPa (m H
2
O)
24.52 (2.5)
32.46 (3.3)
39.32 (4.0)
Hot water production useful heat output
kW (kcal/h)
24.0 (20640)
28.0 (24080)
32.0 (27520)
Domestic hot water adjustable temperature
°C
30 - 60
30 - 60
30 -60
Domestic hot water circuit min. pressure (dynamic)
bar
0.3
0.3
0.3
Domestic hot water circuit max. operating pressure
bar
10.0
10.0
10.0
Minimum D.H.W. flow rate
l/min
1.5
1.5
1.5
Flow rate capacity in continuous duty (∆T 30°C)
l/min
11.5
13.8
16.1
Weight of full boiler
kg
39.0
39.6
41.5
Weight of empty boiler
kg
37.7
38.1
39.5
Electrical connection
V/Hz
230 / 50
230 / 50
230 / 50
Nominal power absorption
A
0.85
0.74
0.83
Installed electric power
W
115
130
150
Pump absorbed power
W
86
84
106
Fan power absorbed power
W
29
46
32
Equipment electrical system protection
-
IPX5D
IPX5D
IPX5D
NO
X
class
-
3
3
3
Weighted NO
X
mg/kWh
128
107
102
Weighted CO
mg/kWh
84
92
63
Type of appliance
C12 /C32 / C42 / C52 / C82 / B22p / B32
Category
II2H3+
- The max. sound level emitted during boiler
operation is < 55dBA. The sound level value is
referred to semianechoic chamber tests with
boiler operating at max. heat output, with
extension of flue gas exhaust system according
to product standards.
STD.002998/004
Summary of Contents for MAIOR EOLO 24
Page 1: ...MAIOR EOLO 24 28 32 Instruction and recommendation booklet 1 038763ENG STD 002998 004 ...
Page 2: ...STD 002998 004 ...
Page 31: ...31 3 5 6 6 7 8 8 f f e INSTALLER USER MAINTENANCE TECHNICIAN STD 002998 004 ...
Page 37: ...37 STD 002998 004 ...
Page 38: ...38 STD 002998 004 ...
Page 39: ...39 STD 002998 004 ...