Maximum usable lengths
(including intake terminal with grill and two 90° bends)
NON-INSULATED PIPE
INSULATED PIPE
Drain (metres)
Intake (metres)
Drain (metres)
Intake (metres)
1
36.0*
6
29.5*
2
34.5*
7
28.0*
3
33.0*
8
26.5*
4
32.0*
9
25,5*
5
30.5*
10
24.0*
* The air intake pipe can be increased to 2.5 metres if the exhaust bend
is eliminated, 2 metres if the air intake bend is eliminated, 4.5 metres
eliminating both bends.
11
22.5*
12
21.5*
Attention:
the boiler is designed to evacuate
the combustion products up to a maximum
extension of 27 linear metres from the exhaust,
with 1 m plus 90° bend at the intake. If the
installation requires a development of the flue
to the discharge that exceeds the recommended
12 m, due consideration must be given to the
formation of condensate that could take place
inside the pipe and insulated flue kits “NOT for
condensing boilers” must be used.
1.13 SEPARATOR KIT INSTALLATION.
Type C configuration, sealed chamber and
fan assisted.
This kit allows air to come in from outside
the building and the exhaust to exit from the
chimney, flue or intubated duct through divided
flue exhaust and air intake pipes. Combustion
products are expelled from pipe (S). Air is taken
in through pipe (A) for combustion. Both ducts
can be routed in any direction.
Separator kit Ø 80/80.
Kit assembly (Fig. 1-21):
install the flange (4) on the central hole of the
boiler, interposing the gasket (1) and tighten
with the flat-tipped hex screws included in the
kit. Remove the flat flange present in the lateral
hole with respect to the central one (according to
needs) and replace it with the flange (3), position-
ing the gasket (2) already present in the boiler and
tighten using the supplied self-threading screws.
Fit the male end (smooth) to the bends (5) in the
female end of the flanges (3 and 4). Fit the intake
terminal (6) with the male section (smooth) in
the female section of the bend (5) up to the end
stop, ensuring that the internal and external wall
sealing plates are fitted. Fit the exhaust pipe (9)
with the male end (smooth) to the female end
of the bend (5) up to the stop; making sure that
the internal wall sealing plate has been fitted, this
will ensure sealing and joining of the elements
making up the kit.
• Installation clearances (Fig. 1-22). The mini-
mum installation clearance measurements of
the Ø 80/80 separator terminal kit have been
stated in some limit conditions.
• Figure 1-23 shows the configuration with verti-
cal exhaust and horizontal intake.
• Extensions for separator kit Ø 80/80. The max.
vertical straight length (without bends) usable
for Ø 80 intake and exhaust pipes is 41 metres
of which 40 intake and 1 exhaust. This total
length corresponds to a resistance factor of
100. The total usable length obtained by sum-
ming the Ø 80 intake and exhaust pipe lengths
can reach, as a maximum, the values provided
in the following table. If
mixed accessories or
components are used
, the maximum extension
can be calculated by using a resistance factor
for each component or its
equivalent length.
The sum of these resistance factors must not
exceed 100.
M
ax 45%
The kit includes:
N°1 - Exhaust gasket (1)
N°1 - Female intake flange (3)
N°1 - Flange gasket (2)
N°1 - Female exhaust flange (4)
N°2 - 90° bend Ø 80 (5)
N°1 - Intake terminal Ø 80 (6)
N°2 - Internal rings (7)
N°1 - External grey wall sealing plate (8)
N°1 - Exhaust pipe Ø 80 (9)
STD.002998/004
Summary of Contents for MAIOR EOLO 24
Page 1: ...MAIOR EOLO 24 28 32 Instruction and recommendation booklet 1 038763ENG STD 002998 004 ...
Page 2: ...STD 002998 004 ...
Page 31: ...31 3 5 6 6 7 8 8 f f e INSTALLER USER MAINTENANCE TECHNICIAN STD 002998 004 ...
Page 37: ...37 STD 002998 004 ...
Page 38: ...38 STD 002998 004 ...
Page 39: ...39 STD 002998 004 ...