32
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
3.18 VARIABLE HEAT OUTPUT.
N.B.:
the pressures indicated in the table repre-
sent the difference in existing pressures between
the gas valve outlet and the combustion chamber.
The adjustments should therefore,be carried out
using a differential manometer (small "U"-shaped
column or digital manometer) with the probes
inserted in the pressure test gas valve outlet and
on the sealed chamber positive pressure test. The
power data in the table has been obtained with
intake-exhaust pipe measuring 0.5 m in length.
Gas flow rates refer to heating power below a tem-
perature of 15°C and at a pressure of 1013 mbar.
Burner pressure values refer to use of gas at 15°C.
Maior Eolo 24.
Maior Eolo 28.
METHANE (G20)
BUTANE (G30)
PROPANE (G31)
THERMAL
POWER
THERMAL
POWER
CH
+
D.H.W.
BURNER GAS
FLOW RATE
PRESS. BURNER
NOZZLES
BURNER GAS
FLOW RATE
PRESS. BURNER
NOZZLES
BURNER GAS
FLOW RATE
PRESS. BURNER
NOZZLES
(kW)
(kcal/h)
(m
3
/h)
(mbar) (mm H
2
O)
(kg/h)
(mbar) (mm H
2
O)
(kg/h)
(mbar) (mm H
2
O)
24.0
20640
2.73
12.30
125.4
2.04
28.50
290.6
2.00
36.70
374.2
23.0
19780
2.62
11.42
116.5
1.96
26.23
267.5
1.92
33.75
344.2
22.2
19120
2.53
10.77
109.8
1.89
24.57
250.5
1.86
31.59
322.1
21.0
18060
2.40
9.77
99.6
1.79
22.03
224.7
1.76
28.30
288.6
20.0
17200
2.29
8.99
91.6
1.71
20.10
204.9
1.68
25.79
263.0
19.0
16340
2.18
8.24
84.0
1.63
18.26
186.2
1.60
23.42
238.8
18.0
15480
2.07
7.52
76.7
1.55
16.52
168.5
1.52
21.17
215.9
17.0
14620
1.96
6.82
69.6
1.47
14.88
151.7
1.44
19.05
194.3
16.0
13760
1.85
6.16
62.8
1.38
13.33
135.9
1.36
17.06
174.0
15.0
12900
1.75
5.52
56.3
1.30
11.87
121.0
1.28
15.19
154.9
14.0
12040
1.64
4.91
50.1
1.22
10.50
107.1
1.20
13.44
137.0
13.0
11180
1.53
4.32
44.1
1.14
9.22
94.0
1.12
11.80
120.4
12.0
10320
1.42
3.76
38.3
1.06
8.03
81.8
1.04
10.29
104.9
11.0
9460
1.31
3.22
32.8
0.98
6.92
70.6
0.96
8.89
90.7
10.0
8600
1.20
2.70
27.6
0.89
5.91
60.2
0.88
7.61
77.6
9.3
7998
1.12
2.36
24.0
0.84
5.25
53.5
0.82
6.79
69.2
8.0
6880
D.H.W.
0.97
1.74
17.8
0.73
4.14
42.2
0.71
5.41
55.2
7.0
6020
0.86
1.30
13.3
0.64
3.40
34.7
0.63
4.50
45.9
METHANE (G20)
BUTANE (G30)
PROPANE (G31)
THERMAL
POWER
THERMAL
POWER
CH
+
D.H.W.
BURNER GAS
FLOW RATE
PRESS. BURNER
NOZZLES
BURNER GAS
FLOW RATE
PRESS. BURNER
NOZZLES
BURNER GAS
FLOW RATE
PRESS. BURNER
NOZZLES
(kW)
(kcal/h)
(m
3
/h)
(mbar) (mm H
2
O)
(kg/h)
(mbar) (mm H
2
O)
(kg/h)
(mbar) (mm H
2
O)
28.0
24080
3.14
11.70
119.3
2.35
28.05
286.1
2.31
35.87
365.8
27.0
23220
3.03
10.91
111.2
2.26
26.32
268.4
2.22
33.41
340.7
26.2
22516
2.94
10.28
104.8
2.19
24.95
254.5
2.16
31.48
321.0
25.0
21500
2.81
9.42
96.1
2.10
23.06
235.2
2.06
28.83
294.0
24.0
20640
2.70
8.73
89.0
2.02
21.52
219.5
1.98
26.71
272.3
23.0
19780
2.59
8.06
82.2
1.94
20.04
204.4
1.90
24.68
251.7
22.0
18920
2.49
7.43
75.8
1.86
18.61
189.8
1.83
22.76
232.1
21.0
18060
2.38
6.82
69.6
1.78
17.24
175.8
1.75
20.92
213.4
20.0
17200
2.27
6.24
63.7
1.70
15.91
162.3
1.67
19.18
195.6
19.0
16340
2.17
5.69
58.0
1.62
14.63
149.2
1.59
17.52
178.6
18.0
15480
2.06
5.16
52.6
1.54
13.39
136.6
1.52
15.94
162.5
17.0
14620
1.96
4.65
47.4
1.46
12.20
124.4
1.44
14.44
147.3
16.0
13760
1.85
4.16
42.4
1.38
11.04
112.6
1.36
13.02
132.8
15.0
12900
1.75
3.70
37.7
1.30
9.93
101.2
1.28
11.67
119.0
14.0
12040
1.64
3.26
33.2
1.23
8.85
90.2
1.21
10.40
106.1
13.0
11180
1.54
2.84
28.9
1.15
7.81
79.6
1.13
9.21
93.9
12.0
10320
1.43
2.44
24.8
1.07
6.80
69.3
1.05
8.08
82.4
11.2
9632
1.34
2.13
21.7
1.00
6.02
61.4
0.98
7.24
73.8
10.0
8600
D.H.W.
1.21
1.70
17.3
0.90
4.89
49.9
0.89
6.06
61.8
9.0
7740
1.10
1.36
13.9
0.82
3.99
40.6
0.81
5.16
52.6
8.5
7310
1.04
1.20
12.2
0.78
3.55
36.2
0.77
4.74
48.3
STD.002998/004
Summary of Contents for MAIOR EOLO 24
Page 1: ...MAIOR EOLO 24 28 32 Instruction and recommendation booklet 1 038763ENG STD 002998 004 ...
Page 2: ...STD 002998 004 ...
Page 31: ...31 3 5 6 6 7 8 8 f f e INSTALLER USER MAINTENANCE TECHNICIAN STD 002998 004 ...
Page 37: ...37 STD 002998 004 ...
Page 38: ...38 STD 002998 004 ...
Page 39: ...39 STD 002998 004 ...