LUXOR
29
21
SAFETY DEVICES
Flue pressure switch: checks the pressure in the flue exhaust circuit.
This blocks the pellet loading auger if the discharge is obstructed or there are significant
backpressures, for example, in case of wind.
When the pressure switch is triggered, “ALAR-DEP-FAIL” will be displayed.
RESET
DOMESTIC
Manual reset safety thermostat for the water temperature: if the water temperature
exceeds the safety value set at 100 °C, boiler operation stops immediately and the screen
will display “ALAR-SIC-FAIL”.
To restart it, you must reset the thermostat manually.
Water temperature probe: if the water temperature approaches the blocking temperature
(100 °C), the probe stops the supply of pellets.
Gearmotor: if the gearmotor stops during the working phase, the “ALAR-NO-FIRE”
warning appears and the boiler continues to operate until the flame goes out as a result
of no fuel and until it reaches the minimum cooling level.
The LUXOR series boilers are equipped with safety devices that
intervene in case of malfunctions.
It is, therefore, forbidden to tamper with these devices.
You must first eliminate the cause that triggered the safety device
before it is possible to ignite the boiler and thus restore operation.
ATTENTION:
All LUXOR models are EN 303-5 certified and
have overcome the safety tests provided by the standard, hav-
ing in particular met the test referred to in point 5.14 (“rapid
disconnection system”).
It is, therefore, not necessary to provide coils or thermal safety
discharges.