32
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
- Flue gas temperature values refer to an air inlet
temperature of 15°C.
- The data relevant to domestic hot water perfor-
mance refer to a dynamic inlet pressure of 2 bar
and an inlet temperature of 15°C; the values are
measured directly at the boiler outlet consider-
ing that to obtain the data declared mixing with
cold water is necessary.
3.20 TECHNICAL DATA.
- The max. sound level emitted during boiler
operation is < 55dBA. The sound level value is
referred to semianechoic chamber tests with
boiler operating at max. heat output, with
extension of flue gas exhaust system according
to product standards.
- (**) When the boiler is connected to an external
storage tank unit.
Nominal heat input
kW (kcal/h)
29.7 (25536)
(**) DHW minimum heat input
kW (kcal/h)
9.9 (8480)
CH minimum heat input
kW (kcal/h)
12.7 (10902)
Nominal heat output (useful)
kW (kcal/h)
28.0 (24080)
(**) DHW minimum heat output (effective)
kW (kcal/h)
8.5 (7310)
CH minimum heat output (useful)
kW (kcal/h)
11.2 (9632)
Efficiency at nominal heat output
%
94.3
Efficiency at 30% nominal heat output load
%
91.5
Heat loss at case with burner On/Off
%
0.0 / 0.53
Heat loss at flue with burner On/Off
%
5.7 / 0.06
Central heating circuit max. operating pressure
bar
3.0
Maximum heating temperature
°C
90
Adjustable central heating temperature
°C
35 - 85
System expansion vessel total volume
l
7.4
Heating expansion vessel pre-charge
bar
1.0
Appliance water content
l
1.3
Head available with 1000 l/h flow rate
kPa (m H
2
O)
32.46 (3.30)
(**) Hot water production useful heat output
kW (kcal/h)
28.0 (24080)
(**) Domestic hot water adjustable temperature
°C
10 -60
(**) Domestic hot water circuit min. pressure (dynamic)
bar
0.3
(**) Domestic hot water circuit max. operating pressure
bar
10.0
Weight of full boiler
kg
38.6
Weight of empty boiler
kg
37.3
Electrical connection
V/Hz
230/50
Nominal absorption
A
0.74
Installed electric power
W
130
Pump consumption
W
84.0
Fan power absorbed power
W
46.0
Equipment electrical system protection
-
IPX5D
NO
X
class
-
3
Weighted NO
X
mg/kWh
107
Weighted CO
mg/kWh
92
Type of appliance
C12 /C32 / C42 / C52 / C82 / B22p / B32
Category
II2H3+