  USE AND MAINTENANCE 

INSTRUCTIONS

2.1  CLEANING AND MAINTENANCE.

Attention: 

to preserve the boiler's integrity 

and keep the safety features, performance and 

reliability, which distinguish it, unchanged over 

time, you must execute maintenance operations 

on a yearly basis in compliance with what is stated 

in the relative point at “annual check and main-

tenance of the appliance”, in compliance with 

national, regional, or local standards in force. 

We recommend stipulating a yearly cleaning and 

maintenance contract with your local technician.

2.2  GENERAL WARNINGS.

Never expose the wall-mounted boiler to direct 

vapours from a cooking surface.

Use of the boiler by unskilled persons or children 

is strictly prohibited.

Do not touch the flue gas exhaust terminal (if pre-

sent) due to the high temperatures it can reach;

For safety purposes, check that the concentric 

air intake/flue exhaust terminal (if fitted), is 

not blocked.

If temporary shutdown of the boiler is required, 

proceed as follows:

a)  drain the heating system if antifreeze is not 

used;

b)  shut-off all electrical, water and gas supplies.
In the case of work or maintenance to structures 

near ducting or devices for flue extraction and the 

relative accessories, switch off the appliance and 

on completion of the operations make sure that 

an authorised company verifies the efficiency of 

the ducting or the devices.

Never clean the appliance or connected parts 

with easily flammable substances.

Never leave containers or flammable substances 

in the same environment as the appliance.
• 

Attenzione:

 the use of components involving 

use of electrical power requires some funda-

mental rules to be observed:

- do not touch the appliance with wet or moist 

parts of the body; do not touch when barefoot;

- never pull electrical cables or leave the appli-

ance exposed to weathering (rain, sunlight, 

etc.); 

-  the appliance power cable must not be replaced 

by the user;

-  if the cable is damaged, switch off the appliance 

and solely contact an authorised company to 

replace it;

- if the appliance is not to be used for a certain 

period, disconnect the main power switch.

N.B.:

 the temperatures indicated by the display 

have a tolerance of +/- 3°C due to environmental 

conditions that cannot be attributed to the boiler.
At the end of its service life, the appliance must 

not be disposed of like normal household waste 

nor abandoned in the environment, but must 

be removed by a professionally authorised 

company. Contact the manufacturer for disposal 

instructions.

Key:

  1  -  Central heating temperature selector

 2 

-

  (*) Domestic hot water temperature 

selector

  3  -  On/Stand-by/Off Button

  4  -  Summer/Winter Button

  5  -  Reset button

  6  -  Boost button (for activating / disabling 

D.H.W. priority)

  7  -  Functioning in summer mode

  8  -  Boiler in Stand-by mode

  9  -  Functioning in winter mode

  10  -  Boiler in block requiring unblock via 

“RESET” button

  11  -  Flame presence symbol and relative 

power scale

 12 - 

Room central heating phase operating 

mode active

  13  -  Solar function active

  14  -  Presence of anomalies

  15  -  Chimney sweep function in progress

 16 

-

 (*) 

D.H.W. production phase operating 

mode active

  17  -  Domestic hot water temperature set

  18  -  Boiler connected to remote control 

V2

 

(optional)

  19  -  Functioning with external temperature 

probe active (optional)

  20  -  Domestic hot water priority function 

active

  21  -  Central heating temperature set

  22  -  Boiler manometer

(*) 

N.B.:

  (when the boiler is connected to an 

external storage tank unit) 

2.3  CONTROL PANEL.

Summary of Contents for 3.020928

Page 1: ...MAIOR EOLO X 28 Instruction and recommendation booklet 1 038769ENG...

Page 2: ......

Page 3: ...specified in the regulations in force and principles of good practice In compliance with legislation in force the systems must be designed by qualified professionals within the dimensional limits esta...

Page 4: ...ce 19 2 2 General warnings 19 2 3 Control panel 19 2 4 Using the boiler 20 2 5 Troubleshooting 21 2 6 Boiler shutdown 22 2 7 Restoring central heating system pressure 22 2 8 System draining 22 2 9 Ant...

Page 5: ...ances underneath the boiler as they could be damaged if the safety valve intervenes if the drain trap is blocked or if there are leaks from the hydraulic connec tions otherwise the manufacturer cannot...

Page 6: ...ts the central heating circuit from freez ing by introducing a top quality anti freeze liquid into this circuit which is not noxious to health The instructions of the manufacturer of this liquid must...

Page 7: ...cal standards in force in order to protect the system and the appliance from deposits e g scale slurry or other hazardous deposits Water connections must be made in a rational way using the couplings...

Page 8: ...h its climate thermostat function disabled i e it must be set to On Off mode Comando Amico Remoto Remote Control V2 or On Off chrono thermostat electrical con nections Optional The operations describe...

Page 9: ...haust in individual flue or to the outside The boiler with this type of configuration is classified as type B22 in accordance with the technical standards in force With this configuration air intake t...

Page 10: ...with the boiler as standard DIAPHRAGM Shutter regulation table Flue gas shutter notch Type of installation duct length in metres 2 4 7 10 60 100 horizontal concentric kit From 0 to 0 5 From 0 5 to 1...

Page 11: ...6 Exhaust m 2 0 Terminal complete with concentric vertical intake exhaust 80 125 Intake and Exhaust 33 m 2 0 m 5 5 Intake m 14 3 Exhaust m 11 0 Concentric vertical intake exhaust termi nal 80 125 Inta...

Page 12: ...it 80 125 Kit assembly Fig 1 18 install the bend with flange 2 onto the central hole of the boiler inserting the gasket 1 and tighten using the screws in cluded in the kit Fit the male end smooth of t...

Page 13: ...in the figure Combustion products are expelled from pipe S Air is taken in through pipe A for combustion The intake pipe A can be installed either on the right or left hand side of the central exhaust...

Page 14: ...screws included in the kit Remove the flat flange present in the lateral hole with respect to the central one ac cording to needs and replace it with the flange 3 positioning the gasket 2 already pre...

Page 15: ...gas exhaust outlets to the same height Temperature loss in insulated flue ducting To prevent problems of flue gas condensate in the insulated exhaust pipe 80 due to flue gas cooling through the wall t...

Page 16: ...edatlowspeedtoensurerelease of air bubbles in the water via the boiler and heating system vents The boiler has a built in automatic venting valve on the circulator Check if the cap is loose Open the r...

Page 17: ...n type B it is compulsory to mount the appropriate top protection cover along with the flue exhaust kit Anti freeze kit with resistance on request If the boiler is installed in a place where the tempe...

Page 18: ...itive signal pressure point 8 Negative signal pressure point 9 Flue pressure switch 10 Flow probe 11 Fumes hood 12 Safety thermostat 13 Primary heat exchanger 14 Ignition and detection electrodes 15 S...

Page 19: ...cal power requires some funda mental rules to be observed do not touch the appliance with wet or moist parts of the body do not touch when barefoot never pull electrical cables or leave the appli ance...

Page 20: ...to the boiler being powered without presence of flame Each time the burner ignites the relative flame present symbol is displayed 11 with relative output scale Operation with Comando Amico RemotoV2 C...

Page 21: ...nables fan start up incorrectly or in the event of a flue gas pressure switch fault If normal conditions are restored the boiler restarts without having to be reset 1 12 Storage tank probe anomaly If...

Page 22: ...y of the appliance and the domestic hot water heating system in areas where the temperature falls below zero we recommend protecting the central heating system with anti freeze liquid and installing t...

Page 23: ...and that the manometer indicates a pressure of 1 1 2 bar make sure the air valve cap is open and that the system is well deaerated switch the boiler on and check correct ignition make sure the gas ma...

Page 24: ...minating resistance R8 The connector X5 is used for the connection to the relay board The connector X6 is for connection to a personal computer The connector X8 is used for software updating operation...

Page 25: ...he type of gas being used S3 Boiler type Establishes the boiler type and its functioning mode 0 combi 1 24 kW storage tank 2 28 kW storage tank 3 32kW storage tank 0 3 2 S4 Power block Establishes the...

Page 26: ...0 P5 Relay 3 optional The boiler is set up for functioning with the relay P C B optional which can be configured 0 Off 1 Chiller remote activation 2 General alarm 3 CH phase active 4 External gas val...

Page 27: ...be adjusted must not be lower than that stated in the tables par 3 18 Adjustment any of the boiler maximum heat output in central heating phase To adjust the maximum heat output during the heating ph...

Page 28: ...tion of approx 10 seconds N B during self check the boiler remains off including signalling 3 15 SOLAR PANELS COUPLING FUNCTION In the event of integration of DHW heating with solar panel systems for...

Page 29: ...the guard a 3 Unhook the decorative frame c from the relative lower retainers 4 Remove the decorative frame c from the cas ing e 5 Loosen the 2 front screws d that fasten the casing 6 Loosen the 2 lo...

Page 30: ...30 3 5 6 6 7 8 8 f f e INSTALLER USER MAINTENANCE TECHNICIAN...

Page 31: ...7 22 0 18920 2 49 7 43 75 8 1 86 18 61 189 8 1 83 22 76 232 1 21 0 18060 2 38 6 82 69 6 1 78 17 24 175 8 1 75 20 92 213 4 20 0 17200 2 27 6 24 63 7 1 70 15 91 162 3 1 67 19 18 195 6 19 0 16340 2 17 5...

Page 32: ...eat output useful kW kcal h 11 2 9632 Efficiency at nominal heat output 94 3 Efficiency at 30 nominal heat output load 91 5 Heat loss at case with burner On Off 0 0 0 53 Heat loss at flue with burner...

Page 33: ...odel code Sr N Serial Number CHK Check Cod PIN PIN code Type Type of installation ref CEN TR 1749 Qnw min Minimum DHW heat input Qn min CH minimum heat input Qnw max DHW maximum heat input Qn max CH m...