  INSTRUCTIONS FOR USE 

AND MAINTENANCE

2.1  CLEANING AND MAINTENANCE.

Attention:

 the heating systems must undergo 

periodical maintenance (regarding this, see 

the section dedicated to the maintenance 

engineer, relating to “yearly appliance check 

and maintenance”) and regular energy efficiency 

checks in compliance with national, regional or 

local provisions in force.

This ensures that the optimal safety, performance 

and operation characteristics of the boiler remain 

unchanged over time.

2.2  VENTILATION OF THE ROOMS.

In the room in which the boiler is installed it 

is necessary that at least as much air flows as 

that requested for by normal combustion of the 

gas and ventilation of the room. The provisions 

relative to ventilation, the flue ducts, chimneys 

and caps are stated in Par. 1.6, 1.7 and 1.8. If 

in doubt regarding correct ventilation, refer to 

professional, qualified staff.

2.3  GENERAL WARNINGS.

Never expose the wall-mounted boiler to direct 

vapours from a cooking surface.

Use of the boiler by unskilled persons or children 

is strictly prohibited.

If temporary shutdown of the boiler is required, 

proceed as follows:

a)  drain the heating system if anti-freeze is not 

used;

b)  shut-off all electrical, water and gas supplies.
In the case of work or maintenance to structures 

located in the vicinity of ducting or devices 

for flue extraction and relative accessories, 

switch off the appliance and on completion of 

operations ensure that a qualified technician 

checks efficiency of the ducting or other devices.

Never clean the appliance or connected parts 

with easily flammable substances.

Never leave containers or flammable substances 

in the same environment as the appliance.

It is prohibited and dangerous to obstruct the air 

intake, even partially, for the ventilation of the 

room in which the boiler is installed.

Due to the danger, functioning is also prohibited 

in the same room as suction devices, chimneys 

or similar at the same time as the boiler unless 

there are additional openings dimensioned in a 

way to satisfy the further necessity for air. For the 

dimensioning of these additional openings, refer 

to qualified technical staff. In particular, an open 

fire must have its own air supply.

On the contrary, the boiler cannot be installed 

in the same room.

• 

Attention:

 the use of components involving use 

of electrical power requires some fundamental 

rules to be observed:

  - do not touch the appliance with wet or 

moist parts of the body; do not touch when 

barefoot;

  - never pull electrical cables or leave the 

appliance exposed to weathering (rain, 

sunlight, etc.);

  - the appliance power cable must not be 

replaced by the user;

  - in the event of damage to the cable, switch 

off the appliance and contact exclusively 

qualified staff for replacement;

  -  if the appliance is not to be used for a certain 

period, disconnect the main power switch.

2.4  CONTROL PANEL.

Fig. 2-1

Key:

  1  -  Flame presence LED

  2  -  Domestic hot water LED

  3  -  Heating LED

  4  -  Temperature LED – Insufficient circulation anomaly

  5  -  Temperature LED – Flow probe anomaly

  6  -  Temperature LED – Ignition block anomaly

  7  -  Temperature LED – Overheating block

  8  -  Temperature LED - Flue gas pressure switch block

  9  -  Stand-by-Domestic water / Remote Control - Domestic water 

and Heating-Reset Selector

  10  -  Domestic hot water temperature selector

  11  -  Central heating temperature selector

  12  -  Boiler pressure gauge

Summary of Contents for 3.018921

Page 1: ...NIKE MINI 28 KW SPECIAL Instruction and warning booklet 1 040845ENG...

Page 2: ...as boilers As for the other issues related to boiler installation e g safety in the work site environment protection injury prevention it is necessary to comply with the provisions specified in the re...

Page 3: ...l heating system pressure 12 2 9 System draining 12 2 10 Anti freeze protection 12 2 11 Case cleaning 12 2 12 Decommissioning 12 3 Boiler start up initial check 13 3 1 Hydraulic diagram 13 3 2 Wiring...

Page 4: ...ies personal responsibility and invalidates the warranty Installation regulations theseboilerscannotbeinstalledinbedrooms studio flats and bathrooms They also cannot be installed in rooms with wood or...

Page 5: ...type used in the boiler which must comply with the regulations in force as insufficient levels can reduce generator output and cause malfunctions Ensure correct gas cock connection by following the m...

Page 6: ...ergas chrono thermostats are connected with 2 wires only Carefully read the user and assembly instructions contained in the accessory kit On Offdigitalchrono thermostat Thechrono thermostat allows set...

Page 7: ...dangerous situations for the user The flue ducts must be connected to the chimney or flue in the same room in which the appliance is installed or at most in the adjoining room and must comply with the...

Page 8: ...intervenes in the eventofgassupplyfailureandchecktherelative intervention time check activation of the main switch located upstream of the boiler The boiler must not be started up even if only one of...

Page 9: ...safety thermostat 6 Fumes hood 7 Delivery probe 8 Safety thermostat 9 System expansion vessel 10 Combustion chamber 11 Boiler circulator pump 12 3 bar safety valve 13 By pass 14 Three way valve motor...

Page 10: ...onnected parts with easily flammable substances Never leave containers or flammable substances in the same environment as the appliance It is prohibited and dangerous to obstruct the air intake even p...

Page 11: ...tacts resistance block LEDs 2 and 7 flash at the same time 04 Parasite flame block LEDs 1 and 7 flash at the same time 20 Loss of remote control communication LEDs 2 and 3 flash alternately 31 Insuffi...

Page 12: ...ure via the valve located at the bottom of the boiler Fig 2 2 N B close the valve after the operation If pressure values reach around 3 bar the safety valve may be activated In this case contact a pro...

Page 13: ...he exit of the appliance combustion products check that there is no backflow of combustion products into the room even during functioning of fans ensure activation of all adjustment devices seal the g...

Page 14: ...ent interventions of the over heating safety thermostat It can depend on reduced water pressure in the boiler little circulation in the heating system the blocked pump or an anomaly of the boiler P C...

Page 15: ...perations must be carried out by a qualified technician e g After Sales Technical Assistance Service Burner adjustment must be carried out using a U or digital pressure gauge connected to the gas valv...

Page 16: ...tables Heating output The boiler is produced and calibrated in the central heating phase at nominal output Permanent reduction of the timer The boiler has an electronic timing device that prevents the...

Page 17: ...with boiler in standby the function activates every 18 hours after the last boiler check power supply In case of functioning in domestic hot water mode the self check starts within 10 minutes after t...

Page 18: ...anel 4 towards you taking care to remove the 2 fixing screws 5 3 16 HEAT OUTPUT N B gasflowratesrefertoheatingpowerbelowa temperature of 15 C and a pressure of 1013 mbar Burner pressure values refer t...

Page 19: ...3994 Domestic hot water adjustable temperature C 38 77 Domestic hot water circuit flow limiter l min 11 Domestic circuit min pressure dynamic bar 0 3 Domestic hot water circuit max working pressure ba...

Page 20: ...Model Cod Md Model code Sr N Serial Number CHK Check Cod PIN PIN code Type Type of installation ref CEN TR 1749 Qnw min Minimum DHW heat input Qn min CH minimum heat input Qnw max DHW maximum heat in...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...Europe S r o 059051 Poprad Matejovce SK Tel 421 524314311 Fax 421 524314316 IMMERGAS SPA ITALY CERTIFIED COMPANY UNI EN ISO 9001 2015 Design manufacture and post sale assistance of gas boilers gas wat...

Reviews: