BPGS10H PNEUMATIC GRIPPER SYSTEM
User Manual
BIM-BPGS10H-0719 Rev 1 | For Technical Assistance: 800-442-4622
8
INSTALLING AN INDIRECT SENSOR
1. To install an Indirect Sensor, apply a liberal amount of high temperature grease to brass bushing prongs inside
sensor. Next, move the brass bushing in the sensor to align with the drive rod slot in the gripper. This must be
done to correctly install sensor. Make sure the sensor is in the orientation where the cable is pointing to the rear of
the gripper.
2. Apply Loctite 262 or equivalent to the three blind M4 tapped holes.
3. Rotate sensor down onto frame. As rotation begins make sure bushing and drive rod slot are still aligned.
Note: Whenever any part of the gripper is replaced including pads, the sensor will need to be recalibrated. See
"Calibrating Indirect Sensor" section.
Bushing Prongs
Drive rod slot