18
Electronic Pressure Sensor 34D
Operation manual
7503755000000050 05/2019
9.4.7 Graphical illustration of the colour change of the display
Display colour change for the parameters
[r1ou]
/
[r2ou],
mode
window function
Display colour change for the parameters
[G1ou]
/
[G2ou],
mode
window function.
Measured value between FL1/FL2 and
FH1/FH2; Display = red
Measured value between FL1/FL2 and
FH1/FH2; Display = green
Colour change display green
Colour change display red
1
Initial value of the measuring range
2
Final value of the measuring range
Display colour change for the parameters
[r1ou]
/
[r2ou]
, mode
hysteresis
function
Display colour change for the parameters
[G1ou]
/
[G2ou]
, mode
hysteresis
function
Measured value > switch point
OUT1/OUT2; Display = red
Measured value > switch point
OUT1/OUT2; Display = green
1
2
FL1/
FL2
FH1 /
FH2
1
2
FL1/
FL2
FH1 /
FH2
1
2
OUT1/
OUT2
1
OUT1/
OUT2
2