All operating elements can be found on the fold-
out page 3.

1

Operating Elements

1.1 Fig. 1: Hand-held microphone

1

Microphone cartridge; to insert batteries, unscrew
the cartridge (figs. 2 to 4)

2

LC display; shows the transmission channel and
the charging status of the batteries during operation

3

Cap for the control part; remove the cap for opera-
tion (fig. 5)

4

Power switch

1.2 Figs. 2 to 4: Inserting batteries

(microphone cartridge unscrewed)

5

4-pole contact, each on the microphone cartridge
(fig. 2) and on the handle (fig. 3);
prior to assembling microphone cartridge and
handle fit the contacts together

6

Lock for the battery holder (7);
to unlock the holder, press the lock in arrow direc-
tion backwards

7

Battery holder for two 1.5 V batteries of size AA (R6)

1.3 Fig. 5: Control part

(cap removed)

8

Key “SET”
with the unit not locked:

to recall and to exit the adjusting modes for chan-
nel/sensitivity/lock function

chapters 5.1, 5.2, and 5.3.1

with the unit locked:

to recall and to exit the adjusting mode for the
lock function 

chapter 5.3.2

9

Key 

for channel selection “down” (in the channel

adjusting mode), to reduce the sensitivity (in the
sensitivity adjusting mode), and to deactivate the
lock function (in the lock mode)

10

Key 

for channel selection “up” (in the channel

adjusting mode), to increase the sensitivity (in the
sensitivity adjusting mode) and to activate the lock
function (in the lock mode)

2

Important Notes

G

The unit is suitable for indoor use only. Protect it
against dripping water and splash water, high air
humidity, and heat (admissible ambient temperature
range 0 – 40 °C).

G

For cleaning only use a dry, soft cloth, by no means
chemicals or water. 

G

No guarantee claims for the unit and no liability for
any resulting personal damage or material damage
will be accepted if the unit is used for other purposes

than originally intended, if it is not correctly operated
or not repaired in an expert way.

3

Applications

In combination with the 2-channel multifrequency re -
ceiver TXS-892 from “img Stage Line” this dynamic
hand-held microphone with integrated multifrequency
transmitter makes up a wireless audio transmis-
sion system. Within the UHF frequency range of 
740 – 764 MHz, the transmission channel can be se -
lected among 16 channels as desired.

The microphone is supplied with a microphone

case, a microphone holder, and 7 push-on caps of dif-
ferent colours.

3.1 Conformity and Approval of the wireless

microphone

Herewith, MONACOR INTERNATIONAL de clare that
the unit TXS-892HT is in accordance with the basic
requirements and the other relevant regulations of
the directive 1999 / 5 / EC. The declaration of conformity
can be found in the  

Internet via the MONACOR

 INTERNATIONAL home page:
www.imgstageline.com

This unit may be operated in the following countries:

DE

The regulations of the country where this unit is oper-
ated must always be observed. These regulations can
be found via links to the national authorities from the
following Internet address:
www.ero.dk

4

Power supply

G

Insert only batteries of the same type and always
replace all batteries.

G

If the unit is not used for a longer period (e. g. more
than a week), remove the batteries. Thus, the unit
will not be damaged in case of battery leakage.

1) Unscrew the microphone cartridge (1).

2) To unlock the battery holder (7), press the lock (6)

in arrow direction backwards.

3) Remove the battery holder up to the stop (fig. 4)

and insert two 1.5 V batteries of size AA (R6) with
the positive and negative connections as indicated
in the holder.

If the unit is to be put out of operation defini -
tively, take it to a local recycling plant for a
disposal which is not harmful to the environ-
ment.

Do not put exhausted batteries/defective rechargea-
ble batteries into the household rubbish but take
them to a special waste disposal (e. g. collective con-
tainer at your retailer).

GB

7

Summary of Contents for 25.2820

Page 1: ...ONE WITH MULTIFREQUENCY TRANSMITTER MICRO MAIN AVEC ÉMETTEUR MULTIFRÉQUENCES MICROFONO A MANO CON TRASMETTITORE MULTIFREQUENZA TXS 892HT Bestellnummer 25 2820 BEDIENUNGSANLEITUNG INSTRUCTION MANUAL MODE D EMPLOI ISTRUZIONI PER L USO MANUAL DE INSTRUCCIONES ...

Page 2: ...r to oper ating the unit Thus you will get to know all functions of the unit operating errors will be prevented and yourself and the unit will be protected against any damage caused by improper use Please keep the operating instructions for later use The English text starts on page 7 GB I Prima di accendere Vi auguriamo buon divertimento con il vostro nuovo apparecchio di img Stage Line Leggete at...

Page 3: ...3 3 1 4 8 9 5 6 7 5 7 2 10 ...

Page 4: ...t kann keine Haftung für daraus resultierende Sach oder Personenschä den und keine Garantie für das Gerät übernommen werden 3 Einsatzmöglichkeiten Dieses dynamische Handmikrofon mit integriertem Multifrequenz Sender bildet zusammen mit dem 2 Kanal Multifrequenz Empfänger TXS 892 von img Stage Line ein drahtloses Audio Übertragungssys tem Der Übertragungskanal kann aus 16 Kanälen im UHF Frequenzber...

Page 5: ...t die Anzeige Hinweis Um den Einstellmodus ohne eine Ein stellung zu verlassen die Taste SET so oft drü cken bis im Display erscheint Das Gerät schaltet danach auf normalen Betrieb zurück 2 Mit den Pfeiltasten den Kanal einstellen mit der Taste 9 werden die Kanäle absteigend durch laufen mit der Taste 10 aufsteigend Die 16 Übertragungskanäle sind folgenden Sen defrequenzen zugeordnet Hinweis Werde...

Page 6: ...ellung durch Drücken der Taste SET speichern Im Display erscheint kurz der Einstellmodus wird verlassen das Gerät wechselt auf Normalbetrieb 6 Austausch Mikrofonkapsel Die Mikrofonkapsel 1 lässt sich gegen die Konden sator Mikrofonkapsel MD 872 von img Stage Line austauschen Diese hat eine Supernieren Richtcha rakteristik und einen größeren Frequenzbereich 50 18 000 Hz 7 Technische Daten Gerätetyp...

Page 7: ...than originally intended if it is not correctly operated or not repaired in an expert way 3 Applications In combination with the 2 channel multifrequency re ceiver TXS 892 from img Stage Line this dynamic hand held microphone with integrated multifrequency transmitter makes up a wireless audio transmis sion system Within the UHF frequency range of 740 764 MHz the transmission channel can be se lec...

Page 8: ...o normal operation 2 Adjust the channel with the cursor keys With the key 9 the channels are scanned in descending order with the key 10 in ascending order The 16 transmission channels are assigned to the following transmission frequencies Note When using other wireless transmission systems with this wireless system at the same time the radio frequencies of the individual systems should be careful...

Page 9: ...e the adjustment by pressing the key SET is shortly displayed the adjusting mode is exited the unit returns to normal operation 6 Replacement Microphone Cartridge The microphone cartridge 1 can be replaced by the capacitor microphone cartridge MD 872 from img Stage Line which is of supercardioid directivity and has an extended frequency range 50 18 000 Hz 7 Specifications Type of unit dynamic hand...

Page 10: ...s éclaboussures dʼune humidité élevée et de la chaleur plage de température de fonctionne ment autorisée 0 40 C G Pour le nettoyer utilisez uniquement un chiffon sec et doux en aucun cas de produit chimique ou dʼeau G Nous déclinons toute responsabilité en cas de dom mages matériels ou corporels si lʼappareil est utilisé dans un but autre que celui pour lequel il a été conçu sʼil nʼest pas correct...

Page 11: ...couleur livrés 7 Pour éteindre le microphone après son fonctionne ment mettez lʼinterrupteur POWER 4 sur OFF Lʼaffichage indique brièvement puis sʼéteint complètement 5 1 Réglage du canal de transmission 1 Maintenez la touche SET 8 enfoncée pendant 2 secondes Sur lʼaffichage clignote Conseil pour quitter le mode réglage sans effec tuer de réglage enfoncez la touche SET jusquʼà ce que sur lʼafficha...

Page 12: ...Marche Arrêt 4 doit être sur ON 2 Maintenez la touche SET 8 enfoncée pendant 3 secondes jusquʼà ce que sur lʼaffichage clignote 3 Enfoncez la touche 9 sur lʼaffichage clignote 4 Mémorisez le réglage en appuyant sur la touche SET Sur lʼaffichage apparaît brièvement le mode de réglage est quitté lʼappareil revient au mode normal 6 Capsule micro de remplacement La capsule micro 1 peut être remplacée ...

Page 13: ...piegare in nessun caso prodotti chimici o acqua G Nel caso dʼuso improprio dʼimpiego scorretto o di riparazione non a regola dʼarte non si assume nes suna responsabilità per eventuali danni consequen ziali a persone o a cose e non si assume nessuna garanzia per lʼapparecchio 3 Possibilità dʼimpiego Questo microfono dinamico a mano con trasmettitore multifrequenza integrato costituisce insieme al r...

Page 14: ...orrono i canali in modo decrescente con il tasto 10 in modo crescente I 16 canali di trasmissione sono assegnati alle seguenti frequenze di trasmissione N B Nel caso di uso contemporaneo di diversi sistemi senza fili conviene sintonizzare bene fra di loro le frequenze dei singoli sistemi per escludere delle interferenze 3 Memorizzare lʼimpostazione premendo il tasto SET Il display segnala brevemen...

Page 15: ...le 6 Sostituzione della capsula del microfono La capsula del microfono 1 può essere sostituita con la capsula per microfoni a condensatore MD 872 di img Stage Line Tale capsula ha la caratteristica di super cardioide e una gamma maggiore di frequenze 50 18 000 Hz 7 Dati tecnici Tipo di apparecchio microfono dinamico a mano con trasmettitore multifre quenza PLL Caratteristica direzionale ipercardio...

Page 16: ...i se aceptará ninguna responsabilidad en caso de daños personales o patrimoniales causados si la unidad se usa para otros fines distintos a los originalmente concebidos si no está correctamente utilizada o si no se repara de manera experta 3 Aplicaciones Combinado con el receptor multifrecuencia de dos canales TXS 892 de img Stage Line este micrófono de mano dinámico con emisor multifrecuencia in ...

Page 17: ...pletamente 5 1 Ajuste del canal de transmisión 1 Mantenga la tecla SET 8 presionada durante 2 seg La pantalla indica brevemente Nota Para abandonar el modo de ajuste sin hacer ningún ajuste presione la tecla SET las veces necesarias hasta que la pantalla indique Luego la unidad vuelve a su funcio namiento normal 2 Ajuste el canal con las teclas cursor con la tecla 9 se buscan los canales en orden ...

Page 18: ...ar puesto en ON 2 Mantenga la tecla SET 8 presionada durante 3 seg hasta que parpadee en la pantalla 3 Presione la tecla 9 parpadea en la pan talla 4 Memorice el ajuste presionando la tecla SET Se muestra brevemente se abandona el modo de ajuste la unidad vuelve al funcionamiento normal 6 Cápsula de micrófono de reemplazo La cápsula de micrófono 1 puede substituirse con la cápsula de micrófono con...

Page 19: ...Copyright by MONACOR INTERNATIONAL GmbH Co KG Bremen Germany All rights reserved A 1143 99 01 07 2010 ...