background image

All operating elements and connections de 

-

scribed can be found on the fold-out page 3.

1

Operating Elements 
and Connections

1

Button MODE to switch between the three oper-
ating modes (

fig. 3):

1. Operation with DMX controller 

chapter 7

(display shows the adjusted DMX start
address, e. g.

)

2. Operation without controller 

chapter 6

(display 

shows ,  or )

3. Slave operation 

chapter 6.1

(display shows 

)

2

Button FUNC to call different functions succes-
sively (

fig. 4):

1. Type of motor positioning for DMX operation

chapter 7.3

2. Rotation of the display indication

(for model LED-122RGB only) 

chapter 5.1

3. Display of the firmware version 

chapter 8

3

LED display to indicate the adjustments

4

Buttons UP and DOWN to change adjustments

5

Mains jack for connection to a socket (230 V~ /
50 Hz) via the supplied mains cable

6

Support for the mains fuse;
only replace a blown fuse by one of the same
type

7

Control input (3-pole XLR chassis plug)

8

Safety lug to fix a safety rope

9

Control output (3-pole XLR jack)

10

Sensitivity control for the internal microphone

11

Microphone for music control

2

Safety Notes

The unit corresponds to all relevant directives of
the EU and is therefore marked with

.

It is essential to observe the following items:

G

The unit is suitable for indoor use only. Protect it
against dripping water and splash water, high air
humidity and heat (admissible ambient tempera-
ture range 0 – 40 °C).

G

Do not place any vessels filled with liquid, e. g. a
drinking glass, on the unit.

G

Do not set the unit into operation, or immediately
disconnect the mains plug from the mains socket
if
1. there is visible damage to the unit or to the

mains cable,

2. a defect might have occurred after a drop or

similar accident,

3. malfunctions occur.
The unit must in any case be repaired by skilled
personnel.

G

Never pull the mains cable to disconnect the
mains plug from the mains socket, always seize
the plug.

G

No guarantee claims for the unit and no liability
for any resulting personal damage or material
damage will be accepted if the unit is used for
other purposes than originally intended, if it is not
safely mounted or not correctly operated, or not
repaired in an expert way.

G

Important for U. K. Customers!

The wires in this mains lead are coloured in  ac -
cord ance with the following code:
green/yellow = earth
blue = neutral
brown = live
As the colours of the wires in the mains lead of
this appliance may not correspond with the
coloured markings identifying the terminals in
your plug, proceed as follows:
1. The wire which is coloured green and yellow

must be connected to the terminal in the plug
which is marked with the letter E or by the earth
symbol  , or coloured green or green and yel-
low.

2. The wire which is coloured blue must be con-

nected to the terminal which is marked with the
letter N or coloured black.

3. The wire which is coloured brown must be con-

nected to the terminal which is marked with the
letter L or coloured red.

Warning – This appliance must be earthed.

If the unit is to be put out of operation
definitively, take it to a local recycling plant
for a disposal which is not harmful to the
environment.

WARNING

The unit is supplied with hazardous
mains voltage. Leave servicing to
skilled personnel only. Do not insert
anything through the air vents! Inex-
pert handling or modification of the
unit may cause an electric shock
hazard.

8

GB

Summary of Contents for LED-102RGB

Page 1: ...EFFETTI DI LUCE CON LED LED 102RGB Bestellnummer 38 5130 LED 122RGB Bestellnummer 38 5140 BEDIENUNGSANLEITUNG INSTRUCTION MANUAL MODE D EMPLOI ISTRUZIONI PER L USO GEBRUIKSAANWIJZING MANUAL DE INSTRUC...

Page 2: ...med din nya img Stage Line produkt L s igenom s kerhetsf re skrifterna innan enheten tas i bruk f r att undvika skador till f ljd av felaktig hantering Beh ll instruktionerna f r framtida bruk S kerh...

Page 3: ...3 1 2 3 4 8 10 9 11 1 2 3 4 7 8 9 11 10 LED 102RGB LED 122RGB 5 6 7 5 6...

Page 4: ...h den am Ger t oder an der Netzanschlussleitung vorhanden sind 2 wenn nach einem Sturz oder hnlichem der Verdacht auf einen Defekt besteht 3 wenn Funktionsst rungen auftreten Geben Sie das Ger t in je...

Page 5: ...passt werden Automatische Lichtshow Reset Modus LEDs aus Die Taste MODE 1 so oft dr cken bis oder im Display 3 angezeigt wird Dann mit der Taste UP oder DOWN 4 aus den drei Modi den gew nschten ausw h...

Page 6: ...sen zugeordnet So sind z B bei Startadresse 5 die Kan le 2 bis 6 den Adressen 6 bis 10 zugeordnet Adresse 11 w re dann die n chstm gliche freie Startadresse f r das folgende DMX gesteuerte Ger t Die T...

Page 7: ...ng durch Staub Rauch oder an dere Schmutzpartikel gereinigt werden Nur dann kann das Licht in maximaler Helligkeit abgestrahlt werden Zum S ubern den Netzstecker aus der Steckdose ziehen Nur ein weich...

Page 8: ...if 1 there is visible damage to the unit or to the mains cable 2 a defect might have occurred after a drop or similar accident 3 malfunctions occur The unit must in any case be repaired by skilled pe...

Page 9: ...has been pressed For model LED 122RGB a rotation of the display indication by 180 is possible Press the button FUNC so many times until the display shows normal indication or indication rotated With t...

Page 10: ...in to the input of the following unit etc until all DMX controlled units are connected in a chain 3 To exclude interferences in signal transmission for long cables or for a great number of units conne...

Page 11: ...trol or reverse control is shown on the display 3 then switch between both adjustments with the button UP or DOWN 4 8 Display of the firmware version To indicate the present version of the firmware op...

Page 12: ...bran chez le imm diatement du secteur lorsque 1 des dommages visibles apparaissent sur l ap pareil ou sur le cordon secteur 2 apr s une chute ou un cas similaire vous avez un doute sur l tat de l app...

Page 13: ...r la touche MODE 1 jusqu ce que sur l affichage 3 ou soit visible Ensuite avec la touche UP ou DOWN 4 s lec tionnez le mode voulu parmi les trois propos s 6 1 Fonctionnement Master Slave Plusieurs app...

Page 14: ...aux 2 6 sont attribu s aux adresses 6 10 l adresse 11 serait l adresse de d marrage libre imm diatement sui vante pour l appareil gestion DMX suivant Appuyez sur la touche MODE 1 jusqu ce que la derni...

Page 15: ...poussi re fum e ou autres particules de salissure C est cette condition que la lumi re sera mise avec une luminosit maximale Pour proc der au nettoyage d branchez la fiche secteur du secteur Utilisez...

Page 16: ...hieri G Non mettere in funzione l apparecchio e staccare subito la spina rete se 1 l apparecchio o il cavo rete presentano dei danni visibili 2 dopo una caduta o dopo eventi simili sussiste il sospett...

Page 17: ...adattare anche la sensibilit del microfono Show automatico di luci Modo Reset LED spenti Premere il tasto MODE 1 tante volte finch sul display 3 si vede o Quindi sele zionare fra i tre modi quello des...

Page 18: ...vi Per esempio con l indirizzo di start 5 i canali 2 6 sono asse gnati agli indirizzi 6 a 10 e l indirizzo 11 sarebbe il prossimo indirizzo di start possibile per l apparec chio successivo comandato d...

Page 19: ...delle lenti per asportare polvere fumo e altre particelle Solo cos la luce pu essere irra diata con la luminosit massima Per la pulizia staccare la spina dalla presa di rete Usare solo un panno morbi...

Page 20: ...n etc op het apparaat G Schakel het toestel niet in resp trek onmiddellijk de stekker uit het stopcontact 1 wanneer het apparaat of het netsnoer zicht baar beschadigd is 2 wanneer er een defect zou ku...

Page 21: ...ssen Automatische lichtshow Reset modus LED s uit Druk enkele keren op de toets MODE 1 tot of op het display 3 verschijnt Selec teer dan met de toets UP of DOWN 4 de gewenste modus uit de drie mogelij...

Page 22: ...tartadres 5 de kanalen 2 tot 6 toegewezen aan de adressen 6 tot 10 adres 11 zou dan het volgende mogelijke vrije startadres zijn voor het volgende DMX gestuurde apparaat Druk enkele keren op de toets...

Page 23: ...f andere vuildeeltjes regelma tig worden gereinigd Alleen dan kan het licht met maximale helderheid worden uitgestraald Trek de stekker uit het stopcontact voor een reinigings beurt Gebruik alleen een...

Page 24: ...ga el aparato en funcionamiento o desco necte inmediatamente el enchufe de la toma de corriente si 1 Existe alg n da o visible en el aparato o en el cable de corriente 2 Aparece alg n defecto por ca d...

Page 25: ...tiene que adaptarse la sensi bilidad del micr fono adecuadamente Exhibici n de luces autom tica Modo Reset LEDs apagados Pulse el bot n MODE 1 hasta que la indicaci n o se muestre en el visualizador...

Page 26: ...la direcci n de inicio 5 los canales 2 a 6 se asignan a las direcciones 6 a 10 la direcci n 11 ser a la siguiente direcci n de inicio libre posible para el siguiente aparato controlado por DMX Pulse...

Page 27: ...s impurezas provocadas por la sucie dad el humo u otras part culas S lo de este modo puede asegurarse de que la luz se irradia con su m ximo brillo Para la limpieza desconecte el enchufe de la toma de...

Page 28: ...twierdzono widoczne uszkodzenie urz dze nia lub kabla zasilaj cego 2 urz dzenie mog o ulec uszkodzeniu na skutek upadku lub podobnego zdarzenia 3 stwierdzono nieprawid owe dzia anie Naprawy urz dzenia...

Page 29: ...ienie diody wy czone Wcisn przycisk MODE 1 kilka razy a na wy wietlaczu 3 pojawi si lub Nast pnie wybra dany tryb za pomoc przyci sk w UP lub DOWN 4 6 1 Tryb master slave Pojedyncze efekty mog zosta p...

Page 30: ...ycisk MODE 1 razy a na wy wietla czu 3 pojawi si ostatnio ustawiony adres np Nast pnie ustawi adres przyciskami UP oraz DOWN 4 Po ustawieniu adresu startowego efekt wietlny mo e by sterowany poprzez k...

Page 31: ...z dzenia Zapewni to uzyskanie maksy malnej jasno ci wiat a Przed przyst pieniem do czyszczenia nale y od czy urz dzenie od zasilania Do czyszczenia obudowy u ywa suchej mi kkiej ciereczki oraz og lnie...

Page 32: ...ytter livsfarlig net sp nding Udf r aldrig nogen form for modifi kationer p produktet og indf r aldrig genstande i ventilationshullerne da du dermed risikere at f elektrisk st d DK L s igenom s kerhet...

Page 33: ...tteen ulkopuoliseen puhdistamiseen pelk st n kuivaa pehme kangasta l k yt milloinkaan vett tai kemikaaleja Optisten osien linssien puhdistukseen voi k ytt lasille sopivaa pesuainetta G Laitteen takuu...

Page 34: ...Copyright by MONACOR INTERNATIONAL GmbH Co KG Bremen Germany All rights reserved A 1164 99 01 10 2010...

Reviews: