The operator has to make sure that safety-relating and machine-technical installations are to be 
inspected by an expert after every year in the course of an acceptance test. 
The operator has to make sure that safety-related and machine-technical installations are to be 
inspected by a skilled person once a year. 
 
The following points have to be considered during the inspection: 
01)

 

All screws used for installing the device or parts of the device have to be tightly connected and 
must not be corroded. 

02)

 

There may not be any deformations on housings, fixations and installation spots. 

03)

 

Mechanically moving parts like axles, eyes and others may not show any traces of wearing. 

04)

 

The electric power supply cables must not show any damages or material fatigue. 

 

The 

BEAM-4/

RGBW requires almost no maintenance. However, you should keep the unit clean.  

Otherwise, the fixture’s light-output will be significantly reduced. Disconnect the mains power supply, and 
then wipe the cover with a damp cloth. Do not immerse in liquid. Wipe lens clean with glass cleaner and 
a soft cloth. Do not use alcohol or solvents. 
The front lens will require weekly cleaning, as smoke-fluid tends to build up residues, reducing the light-
output very quickly. 
The cooling-fans, color-wheel, the gobo wheel, the gobos and the internal lenses should be cleaned 
monthly, with a soft brush. 
Please clean internal components once a year with a light brush and vacuum cleaner.  
Keep connections clean. Disconnect electric power, and then wipe the DMX and audio connections 
with a damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying 
electric power. 

 

Replacing the Fuse 

Power surges, short-circuit or inappropriate electrical power supply may cause a fuse to burn out. If the 
fuse burns out, the product will not function whatsoever. If this happens, 

follow the directions below to do 

so.

 

01)

 

Unplug the unit from electric power source

02)

 

Insert a screwdriver into the slot in the fuse cover. 

Turn the fuse holder counterclockwise. 

The fuse will 

come out

03)

 

Remove the used fuse. If brown or unclear, it is burned out

04)

 

Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse holder. Be sure 
to 

use a fuse of the same type and specification. See the product specification label for details. 

 

Troubleshooting 

This troubleshooting guide is meant to help solve simple problems.  
If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit 
operates properly, do not carry out following steps. 
 

No Light 

If the light effect does not operate properly, refer servicing to a technician. 
Response: Suspect three potential problem areas as: the power supply, the lamp, the fuse. 
01)

 

Power supply. Check that the unit is plugged into an appropriate power supply. 

02)

 

The LED. Return the 

BEAM-4/

RGBW to your 

IMG Stage Line

 dealer. 

03)

 

The fuse. Replace the fuse. See page 25 for replacing the fuse. 

04)

 

If all of the above appears to be O.K., plug the unit in again.  

05)

 

If you are unable to determine the cause of the problem, do not open the 

BEAM-4/RGBW

, as this may 

damage the unit and the warranty will become void. 

06)

 

Return the device to your 

IMG Stage Line

 dealer. 

 

 

Summary of Contents for BEAM-4/RGBW

Page 1: ...BEAM 4 RGBW Order No 38 0230 ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS INSTRUCTION MANUAL LED Beam Moving Bar RGBW...

Page 2: ...ling 11 Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13 Main Menu Options 15 1 Manual Mode 15 1 1 Manual Mode LED 15 1 2 Manual Mode Pan 16 1 3 Manual Mode Tilt 17 2 Built in Progr...

Page 3: ...BEAM 4 RGBW PowerCon to Schuko 1 5 m 1 bracket and 3 quick locks User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the accelera...

Page 4: ...g the device Only use the device indoors avoid contact with water or other liquids Only operate the fixture after having checked if the housing is firmly closed and all screws are tightly fastened Onl...

Page 5: ...be exceeded The relative humidity must not exceed 50 with an ambient temperature of 40 C If this device is operated in any other way than the one described in this manual the product may suffer damage...

Page 6: ...with the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLO...

Page 7: ...00 240V 60 50Hz Power consumption 60W DMX channels 1 22 26 Clear LCD display for easy setup Sound Control Control modes DMX Auto Manual Sound Slave Control protocol DMX 512 5 pin DMX signal connector...

Page 8: ...splay control buttons 03 5 pin DMX signal connector OUT 04 5 pin DMX signal connector IN 05 Power switch ON OFF 06 Fuse T3A 250V Backside Fig 03 07 Blue White power connector IN 100 240V 08 Blue White...

Page 9: ...tric power supply socket 03 When the BEAM 4 RGBW is not connected with a DMX cable it functions as a stand alone device Please see pages 16 18 for more information about the Auto Mode and Manual Mode...

Page 10: ...le to connect the BEAM 4 RGBWs and other devices 04 Link the units as shown in fig 05 Connect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this proc...

Page 11: ...s the data link can support Important Fixtures on a serial data link must be daisy chained in a single line To comply with the EIA 485 standard no more than 30 devices should be connected on one data...

Page 12: ...the first BEAM 4 RGBW should be 1 001 the DMX address of the second BEAM 4 RGBW should be 1 26 27 027 the DMX address of the third one should be 27 26 53 053 etc Please be sure that you do not have a...

Page 13: ...13 Order No 38 0230 BEAM 4 RGBW Menu Overview See next page for the remaining menu functions...

Page 14: ...14 Order No 38 0230 BEAM 4 RGBW...

Page 15: ...e 2 adjustable options Speed Frequency 05 When the display shows press the SETUP button to enter the menu 06 You can now adjust the speed of your light show The adjustment range is between from slow t...

Page 16: ...is between 0 255 from dark to brightest 23 When the display shows press the SETUP button to enter the strobe settings 24 Press the UP and DOWN buttons to adjust the strobe intensity The adjustment ran...

Page 17: ...between 04 The device will now run the chosen automatic show 3 Sound controlled Mode 01 While in the main menu press the UP and DOWN buttons until the display shows 02 Press the SETUP button to enter...

Page 18: ...ton to enter tilt adjustment 05 Press the UP and DOWN buttons to adjust tilt Both positive and negative values are possible 6 3 Settings Reset 01 When the display shows press the SETUP button to enter...

Page 19: ...ETUP button to reset both history and current status 14 When the display shows press the SETUP button to run the reset or the MODE button to cancel the reset 15 Repeatedly press the MODE button to ret...

Page 20: ...an fine 16 bit Channel 3 Vertical movement Tilt Push the slider up in order to move head vertically TILT Gradual head adjustment from one end of the slider to the other 0 255 128 center The head can b...

Page 21: ...255 Gradual adjustment Red from 0 100 Channel 20 LED 4 Green intensity 0 255 Gradual adjustment Green from 0 100 Channel 21 LED 4 Blue intensity 0 255 Gradual adjustment Blue from 0 100 Channel 22 LED...

Page 22: ...ensity Dimmer must be open 0 255 Gradual adjustment Red from 0 100 Channel 13 LED 2 Green intensity Dimmer must be open 0 255 Gradual adjustment Green from 0 100 Channel 14 LED 2 Blue intensity Dimmer...

Page 23: ...29 Built in show 1 30 39 Built in show 2 40 49 Built in show 3 50 59 Built in show 4 60 69 Built in show 5 70 79 Built in show 6 80 89 Built in show 7 90 99 Built in show 8 100 109 Built in show 9 110...

Page 24: ...ectric power and then wipe the DMX and audio connections with a damp cloth Make sure connections are thoroughly dry before linking equipment or supplying electric power Replacing the Fuse Power surges...

Page 25: ...ome respond erratically or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables...

Page 26: ...Manual Sound Slave Sound Control LED Quantity 4 x 10W RGBW LED Color mixing RGBW Beam angle 3 Pan Tilt range 540 or continuous depending on DMX Channel 200 Pan Tilt resolution 16 bit Dimmer 0 100 Stro...

Page 27: ...27 Order No 38 0230 BEAM 4 RGBW Dimensions...

Page 28: ...28 Order No 38 0230 BEAM 4 RGBW...

Reviews: