Fit the rear doors in the same manner. There are two plastic blocks supplied, which if placed in 

the bottom channels in front of the glass will    prevent the doors from opening. 

 
 
 
 
Shelving system 

There  are four  upright  channels  which  locate  into  slots  provided  inside  the  unit.  The  channels 

have a flat tab at each end the top side is slightly longer. Place the channel vertically into the slot 

provided  in  the  top  of  the  unit  and  then  drop  down  to fit  through  the  corresponding  slot  in  the 

bottom. Ensure that flat sides are facing inside the unit. The shelf support angles fit into the slots 

in the upright channel. 

They  can  be  positioned  level  or  slopping  forward  according  to  preference.  The  wire  shelf  is 

positioned on top of the support angle and fits against the securing tab at the rear of the support 

angle which prevents the shelf from sliding forward. 

 

5.3 Operating 

 

ATTENTION!   

The operation of the device may only be carried out by personnel that have been instructed in 
operation of the device   
Before first use, clean the inside chamber and the tray grids with a piece of wet cloth dampened 
with non-abrasive detergent. After cleaning, dry the unit thoroughly. 
Take out the water pan inside the chamber. Fill water inside the water pan. The water inside is to 
produce moisture to keep the inside environment wet. Fill the water as long as it does not spill 
over. Monitor the water level to add the water when necessary. 
Connect  the  unit  to  a  suitable  power  supply.  Rotate  the  thermostat  clockwise  to  your  desired 
value. The yellow indicator would flush on automatically. You may also turn the illuminators on to 
give  your  customer  an  impressive  feeling.  The  inside  temperature  of  the  chamber  would  be 
displayed clearly on the temperature display. When you turn the illuminator on, the red indicators 
on the switch will light on. Observe the water level in the pan, add water when the water inside 
the pan is lowered to certain positions. 
When one day

’s work has been finished, shut the main switch off. Unplug the plug. 

 

6. Transportation, Cleaning and maintenance   

6.1 Transportation 

In  the  process  of  transportation,  the  appliance  should  be  handled  carefully,  preventing  the 
intense  shaking.  The  packaged  appliance  should  be  stored  in  a  well-ventilated  area  free  of 
caustic air. It cannot be placed in the outside area and should never be put upside down. Keep it 
dry and dust-free. Do not expose it to direct sunlight. Avoid mechanical shocks and vibrations. If 

Summary of Contents for FM-26

Page 1: ...Model FM 26 FM 36 FM 48 Please read this instruction manual carefully before operating this equipment Hot Display Instruction Manual ...

Page 2: ...er and electrical cords Warning Electrical Grounding Instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug If the output exceeds a certain value the plug will not be used Connect the wire to a suitable ai...

Page 3: ...icable safety regulations The instruction manual forms part of the product and should be kept near the appliance and easily accessible for anyone carrying out the installation servicing and maintenance or cleaning 1 3 Note NOTE Read the instruction manual carefully before using the appliance The user s manual should be kept near the appliance easily accessible for anyone to operate the unit We res...

Page 4: ...ea of application of the device must be followed and complied with The device should be never left unattended during operation Special attention should be paid to when the unit is in use if the children are near the appliance This manual is considered to be a permanent part of the appliance Preserve this manual safely for the reference of operators When passing on selling the device to a third par...

Page 5: ...g regularly 4 Technical data Model FM 36 FM 26 FM 48 Power Input 1 84KW 1 84KW 2 2KW Rated Voltage 220 240V 220 240V 220 240V Frequency 50 60Hz 50 60Hz 50 60Hz Temperature range 30 110 30 110 30 110 Dimensions mm 900X480X590 660X437X655 1200X480X810 5 Installation and operation 5 1 Safety instructions WARNING Electrical hazard The appliance should be connected to a suitable power receptacle The ou...

Page 6: ...n top of a solid even safe and stable surface that tolerates the weight Level it back and forth Then leave it side to side Not at any time should you place the appliance on top of an inflammable surface such as table cloth carpet etc You must not locate the appliance near open fireplaces electric ovens electric heaters or other heat sources Position the device appropriately so that the plug is alw...

Page 7: ...nt After cleaning dry the unit thoroughly Take out the water pan inside the chamber Fill water inside the water pan The water inside is to produce moisture to keep the inside environment wet Fill the water as long as it does not spill over Monitor the water level to add the water when necessary Connect the unit to a suitable power supply Rotate the thermostat clockwise to your desired value The ye...

Page 8: ...olution You must not let water enter the switching unit This may lead to dangerous creepage current and malfunctions of the appliance Do not use any aggressive cleaning agents or abrasive materials as these could damage the protecting film of the stainless steel and leave the iron particles on the surface of the unit which can cause rust All parts must be dried thoroughly and reassemble the parts ...

Page 9: ...s manual must be read and understood by all persons using or installing this appliance Contact your local dealer if you have any questions concerning installation operation or maintenance of this equipment 9 WARRANTY iMettos warrants to the original purchaser of every new product under normal and proper use and maintenance service as specified by iMettos and upon proper installation and start up i...

Page 10: ...9 iMettos Limited www imettos co uk ...