Operation manual EPM-Peak
Software Release 1.0.8.0 2019-01-29
Page 16 of 19
8
Check tightening of sensor on adaptor
It must be tighten the sensor and adapter connection part firmly before measuring operation for safety of worker.
Please check regularly tightening of sensor on adaptor. Use tools with wrench size 19mm and 22 mm (fig.28and
fig.29). Max. torque 30 Nm.
Fig. 28: Disconnection of spring
Fig.29: Disconnection of CPS cylinder pressure sensor
from adaptor
Note: It is not allowed to use a hammer or equivalent tool to open or close the adaptor.
The user must use spanner tool on pins for to close or open adaptor on indicator cock !
19 mm wrench size tool
22 mm wrench size tool
Use tool for
disconnection of
spring from adaptor