10.2 WATER CONNECTION
Connect the water hose (table 1) from the pump to the water
mains.
The water mains must guarantee a minimum flow rate of
15l/min.
Otherwise a tank of suitable capacity (200 l) must be fitted with
clean water, to be kept full at all times, and from which water can
be taken by means of the self-priming pump supplied with the
machine. In this case the hose must have a minimum diameter of
3/4", a maximum length of 3m, preferably a foot filter and must
not be subject to deformation during use. Ensure that pressure
is sufficient. Turn the main switch to 1; the green light on the
panel illuminates (ref.8)
- CAUTION! The first time the water pump is connected
to the tank, it must be activated by manually filling the
intake line.
The same operation must be repeated each time the
circuit is drained, or after a prolonged period of disuse.
10.3 AIR CONNECTION
Connect the air hose to the machine panel and spray jet as
shown in the figure below.
Open the spray jet air valve.
FIG.7
10.3 CORRECT CONNECTIONS FOR MATERIAL LINES
Take the material hoses and check that they are in perfect
condition, that the couplings are intact and all relative seals are
present. Check that the cam levers ( A ) of the couplings have
been tightened correctly and that the seal (B) is fitted as shown
in the figure below.
( A )
( B )
11. START-UP
Before starting up the machine, check that the air valve on the
spray jet is open (ref.11).
Turn the main switch (ref.1) on the electrical panel to 1; the
compressor is activated. Using the two pushbuttons (ref.3),
access start command n°2(ref.4) on the display.
Remove the water level cap (ref.12), positioned a the side on the
lower section of the hopper unit and ensure that there is no
material obstructing the hole. If clogged, clean by means of the
longer section of the water level cap.
Press the water supplement button (ref.9) and check that the
water comes out of the relative hole of the water level cap. Use
the micrometric valve (ref.13) to set the water flow rate, as
displayed by the flow meter (ref.14) respectively
-at 300 l/min for cement-based products
-at 500 l/min for gypsum based products
Refit the water level cap in its hole and close securely.
Load the hopper with the relative premixed material in sacks.
Position the start selector (ref.5) to ON (rotate to the right), to
start up the machine.
Wait for material to be delivered from the jet and at the same time
load the material hopper.
At this point the mix delivered by the jet can be adjusted by
correcting the quantity of water as required.
Use the micrometric valve, reducing the flow rate by 20l at a
time, to obtain the required consistency.
When the jet starts to deliver material at the required consistency,
normal work can be started.
The machine starts and stops by opening and closing the air
supply to the spray jet.
The machine is fitted with protection against power failure or
surges (see paragraph
Errors,
page 8): if one of these events
occurs, the thermal cut-out trips. In this case reset the switch
(ref.5) and turn the main switch to 1.
In the event of water pressure failure (see table
Troubleshooting,
page 10), the motor shuts down and the green light turns off
(ref.8). The machine restarts automatically when sufficient
pressure is restored.
To stop the machine in the event of an emergency, press the red
emergency button (ref.10) - all moving parts are shut down -
then turn the main switch to 0 and remove the electric power
plug from the mains socket.
Summary of Contents for KOINE 3
Page 1: ...MORTAR MIXER Operating maintenance spare parts manual KOINE 3 1106007 1106008 1106009...
Page 8: ...7 IMER INTERNATIONAL S p A KOINE 3 11 13 12 14 1 5 4 6 10 2 3 8 7 9...
Page 18: ...17 IMER INTERNATIONAL S p A Z z y V y z K y U VV V V U Z V VK U z V y z VU U U Z U R LJ JK P J...
Page 25: ...24 IMER INTERNATIONAL S p A IEC WT M PPQ E E WT...