For the retention of the serviceability of the machine the condenser 
is, to keep that is behind the front rust clean To that is for the 
elimination of the 

dirt

 on the bracings 

\Pic

. 14) to carry out a 

monthly 

cleaning

 

with a metal brush and a vacuum cleaner. Do not 

employ any peaked subjects. 

 

During the maintenance and 

cleaning

 

jobs

 gloves are to use, some 

eyeglasses and a protection mask. 
After these work flows are that one before the engagement 
Equipment the protectors again attach. 

 

 

Non standard maintenance

 

This maintenance may be carried out only by the specialists 
that is authorized to jobs and this product typology. 

 

Disposal

 

The cold producer is equipped wit h refrigerant or with 
lubricating oil. From that the disposal in this connection or 
elimination of the severe observation of the valid rules of law of 
the country are, in which the installation is carried out., 
subordinate. 
 

Summary of Contents for SF 10 N

Page 1: ...Page0 OPERATING MANUAL BLAST CHILLER...

Page 2: ...Page1 Device Article number Type Part number SF 5P 07900 SF 5 N 07901 SF 6P 07902 SF 6 N 07903 SF 10P 07904 SF 10 N 07905 SF 20P 07906 SF 20 N 07907...

Page 3: ...f contents Page 2 Preface Page 3 Information about gas safety Page 4 Installation Page 5 Control panel Page 7 Engagement of the operations Page 9 Cleaning and maintenance Page 10 Guarantee assurance P...

Page 4: ...down to an inappropriate use of the product onto a transport with inappropriate means onto illicit alterations as well as all steps that were not considered in this instruction the manufacturer does...

Page 5: ...ial dangers Increase of pressure Special means Chilling with water Measures with accidental gas escape Individual precautions Bringing the personnel into safety rooms Anticipating an adequate aeration...

Page 6: ...ct air circulation Pic 4 Pic4 Make that freedom of movement is available sufficiently for the maintenance operations The device may not be in rooms with small air circulation into the full sun with hi...

Page 7: ...hat were caused through an unproper installation Protection appliances at the device Door Micro switch Safety pressure switch stops the apparatus operation near doorway Turns on at over and lower pres...

Page 8: ...TART STOP press button Compressor Led Temperature timedisplay display Cooling press button Deepfreeze press button Storage press button Alarm Led Time press button Led exhaust wheels Pin probe Led Tha...

Page 9: ...repared one goes from to the cooling to the storage preserving about The display gives the still missing time to at the end of the cool course at Through Keystroke pin probe becomes some seconds take...

Page 10: ...owing Led s to light up onto Cooling Deepfreeze Storage There are three choices Cooling in the product heart advisable Pressing press button to cooling if after the cooling the foods press button are...

Page 11: ...or diluent employ Out the possibility the water of condensation onto the ground to let tile Pic 9 our products also with one are Receptacle to the water of condensation absorption loads that regular...

Page 12: ...are to use some eyeglasses and a protection mask After these work flows arethat one before the engagement Equipment the protectors again attach Non standard maintenance This maintenance may be carried...

Page 13: ...escribed tension as well as at perfect voltage ratios correct service as well as installed in conformity to regulations from which Operating manual clear maintenance expert installation through a lice...

Page 14: ...ccessories and attachments which are indicated in the operating manual The use of other accessories can mean a danger for you 7 This device is exclusively to the chilling and freezing of suitable food...

Reviews: