background image

 

 

Page

Engagement the following 

operations

 through respective keystroke possible: 

 

1. Cooling  

(

+70°C/+3°C

Press button

 

Press button cycle start

 

 

2. Deepfreeze 

(

+70°C/

-18°C) 

Press button

 

Press button cycle start

 

 

3. Storage 

(+3°C) 

Press button

Led at 

Press button cycle start

 

 

4. Storage 

(-18°C) 

Press button

 Led at 

Press button cycle start

 

 

5. Cooling 

(

+70°C/+3°C

) s (

+3°C

Press button

+Button

 

Press button cycle start

 

 

6. Deepfreeze 

(

+70°C/

 18°C) s (-

18°C

Press button

+Button

 

Press button cycle start

 

 

Course of events manner

 

The food into the cell pursue pin probe into the middle of the product 
to be chilled insert. 
 
ON/OFF takes about the press 

button 

turning on On the display 
the 

SEL information appears 

and 

the following Led's to light up 

onto. 

 

Cooling   

Deepfreeze 

Storage 

 
There are three choices. 
 

Cooling in the product heart 
(advisable)

 

Pressing press button to 

cooling

 

(if after the cooling the foods 
) press button are supposed to be lain 
down 

Pressing storage

Cycle through START/STOP keystroke 
to turn on ON the display appears 
the one measured from the probe 
Temperature level. 

Deepfreeze in the product heart 
(advisable)

 

Pressing press button to deepfreeze

 

if after the deepfreeze the foods 
) storage press button are supposed to be lain down 

press.

 

Cycle through START/STOP keystroke 

turn on and on that  

Display appears to that of the probe 
measured temperature level. 
 
After the cooling and deepfreeze 
become in case of turned on storage 
the foods 

with

 a temperature level 

from 

+3C

 (after the cooling) or -18 C 

(after the deepfreeze) keeps. 
In Any Case appears on the display 
the respective temperature level of the cell. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SF 10 N

Page 1: ...Page0 OPERATING MANUAL BLAST CHILLER...

Page 2: ...Page1 Device Article number Type Part number SF 5P 07900 SF 5 N 07901 SF 6P 07902 SF 6 N 07903 SF 10P 07904 SF 10 N 07905 SF 20P 07906 SF 20 N 07907...

Page 3: ...f contents Page 2 Preface Page 3 Information about gas safety Page 4 Installation Page 5 Control panel Page 7 Engagement of the operations Page 9 Cleaning and maintenance Page 10 Guarantee assurance P...

Page 4: ...down to an inappropriate use of the product onto a transport with inappropriate means onto illicit alterations as well as all steps that were not considered in this instruction the manufacturer does...

Page 5: ...ial dangers Increase of pressure Special means Chilling with water Measures with accidental gas escape Individual precautions Bringing the personnel into safety rooms Anticipating an adequate aeration...

Page 6: ...ct air circulation Pic 4 Pic4 Make that freedom of movement is available sufficiently for the maintenance operations The device may not be in rooms with small air circulation into the full sun with hi...

Page 7: ...hat were caused through an unproper installation Protection appliances at the device Door Micro switch Safety pressure switch stops the apparatus operation near doorway Turns on at over and lower pres...

Page 8: ...TART STOP press button Compressor Led Temperature timedisplay display Cooling press button Deepfreeze press button Storage press button Alarm Led Time press button Led exhaust wheels Pin probe Led Tha...

Page 9: ...repared one goes from to the cooling to the storage preserving about The display gives the still missing time to at the end of the cool course at Through Keystroke pin probe becomes some seconds take...

Page 10: ...owing Led s to light up onto Cooling Deepfreeze Storage There are three choices Cooling in the product heart advisable Pressing press button to cooling if after the cooling the foods press button are...

Page 11: ...or diluent employ Out the possibility the water of condensation onto the ground to let tile Pic 9 our products also with one are Receptacle to the water of condensation absorption loads that regular...

Page 12: ...are to use some eyeglasses and a protection mask After these work flows arethat one before the engagement Equipment the protectors again attach Non standard maintenance This maintenance may be carried...

Page 13: ...escribed tension as well as at perfect voltage ratios correct service as well as installed in conformity to regulations from which Operating manual clear maintenance expert installation through a lice...

Page 14: ...ccessories and attachments which are indicated in the operating manual The use of other accessories can mean a danger for you 7 This device is exclusively to the chilling and freezing of suitable food...