26
System Description
Sysdescr offers the options of assigning a system name, System Contact System
Location, Unit Description and individual Port names. Enter a description or name,
up to 32 characters per line. Press the
Enter
key to complete the editing task.
To change the MIB name of the IE-MiniFiberLinX-II as it appears on the network,
type
sysname
and press
Enter
. Enter a new name, not exceeding 16 characters in
length.
Unit Control Settings
Serial/Telnet sessions display unit status as well as allowing configuration of some of
the IE-MiniFiberLinX-II features. Type
unit
and press
Enter
to be taken to the Unit
screen. From this screen, view the settings for FlowControl, FiberAlert, LoopBack,
Maximum Frame Size, 802.1p Base Priority, Last Gasp.
For Telco/LastGasp Model only
Use the arrow keys to navigate and the Space Bar to change the values on this screen.
These settings include:
Unit FlowControl
Enable/Disable
FlowControl
Unit FiberAlert
Enable/Disable
FiberAlert
Unit LoopBack
Enable/Disable the various LoopBack testing modes
Unit Max FrameSz
Set the maximum Frame Size to pass through the ports:
1518, 1522, 1536, or 1916.