Voltage Selection
The transformer for the power supply is provided with a dual primary
winding that enables the unit to operate at either 100-120 VAC or
200-240 VAC, depending on the jumper connection.
Note
Voltage selection is normally done during the manufacturing
process, based on indicated customer requirements.
To set the voltage, follow this procedure:
1. Remove AC power from the clock, and then remove the cover.
2. Locate the dual primary winding voltage selector.
See
Figure A-1
.
Figure A-1.
Location of Dual Primary Winding
3. Solder both voltage selectors horizontally on the board for 120
VAC or vertically for 240 VAC. See exploded diagram in
Figure A-1
.
4. Replace the top panel and all screws.
5. Reapply AC power to the clock, and then confirm start-up.
110
110
22
0
Winding Voltage Selector Settings
Solder both voltage selectors horizontally on the board for 120
VAC (as shown). Remove and solder both voltage selectors
vertically on the board for 240 VAC.