Once the DTD-523x are configured as timecode generators, the rear
panel terminals will output real-time timecode when DIP switch
1-4
is
set to the
Internal
(closed) position.
The DTD-523x makes use of an internal crystal for a time base when
operated in
Internal Timecode Generator Mode
. Additionally, DIP
switch
1-2
is set to the
Run on Secondary
(opened) position. This
disables the flashing colon LEDs.
Timecode Format
Select the output timecode format by moving DIP switch
1-5
to either
the
SMPTE
(closed) position or
EBU
(opened) position.
Brightness Adjustment
You can adjust the brightness of the LED display incrementally by
simultaneously holding the
MANUAL SET
button and either the I
NC
or
RESET DEC
button on the rear panel.
1. Hold
MANUAL SET
and
INC
to increase the brightness one level
per second.
2. Hold
MANUAL SET
and
RESET DEC
to decrease the brightness
one level per second.
There are 16 brightness levels to choose from.
.
Figure 3-3.
DTD-523x Rear Panel
SW1~SW6
RESET MANUAL
INC DEC SET
TIMECODE
GND
TIMECODE
IN/OUT
100-120
200-240
100-120 VAC/200-240 VAC
50/60 Hz
0.25/0.15 A max.
INC (Increase) Button
RESET/ DEC
(Decrease) Button
MANUAL SET
Button