Dseries Harris J/S (JSC-2) Jog-Shuttle Control Panel  
Reference 

 

J/S (JSC-2) Ingest Control Panel 

 

 

The jog/shuttle mechanism is a weighted jog wheel and a concentric shuttle ring.  

 

20 control buttons 

 

5 dedicated transport controls 

 

A back-lit LCD time code display for easy and accurate editing. 

V2.14 Firmware  

The JSC-2 Ingest Panel uses firmware v2.14 to support jog/shuttle status query 
commands. 

Note

: Firmware versions prior to v2.14 do not support jog/shuttle querying and the 

LCD display will appear to become unresponsive if left idle or in the ‘shuttle’ position 
for a period of time. Moving the shuttle wheel or pressing any button on the control 
panel will reupdate the display. 

Specifications 

The following table provides a brief list of specifications for a JSC-2 Panel.  

 

Specification 

Description 

Size 

10.5” x 6.5” x 3.5”   (26.7 x 16.5 x 8.9) 

Weight 

4 lbs (1.8 KG) 

Power Requirements 

The JSC-2 comes with an external power supply ‘brick’:  
(universal, 12 volt DC switching power supply). If you 
need a power cord specific to your location, please 
contact your local distributor. 

Warning

Using a power supply other than the unit 

specified can result in damage to the panel and/or other 
equipment which is not covered by the manufactures 
Warranty

Power Consumption 

Vendor-specified power input and output information is 
printed on the power supply label: 

Power Input =    100-240V AC at 0.45A peak 

Power Output = 12V DC at 1.25A max. 

Inputs/Outputs 

RS-422 (x1) 

Typical Location 

In close proximity to the operator workstation.  

Mounting 
Requirements 

No mounting is required. Since this is a desktop unit, 
only sufficient desk space is required. 

 

© 2014 Imagine Communications Corp.     Proprietary and Confidential 

 9-April-2014  | Page 8 of 21 

Summary of Contents for 502072-00

Page 1: ...Reference D Series Harris J S JSC 2 Jog Shuttle Panel Reference 11 April 2011...

Page 2: ...magine Communications reserves the right without notice to make such changes in equipment design specifications components or documentation as progress may warrant to improve the performance of the pr...

Page 3: ...imecode Display 10 Jog Shuttle Wheel 10 Direction Indicator 10 Button Mapping 11 DALstation Functionality 11 DALingest Functionality 14 Troubleshooting 17 Loss of JSC 2 Comms 17 Configuration 18 DALst...

Page 4: ......

Page 5: ...articles immediately upon receipt Any damage discovered should be cause for a damage claim against the carrier WEEE and RoHS Compliance Panels addressed in this document are WEEE and RoHS Compliant T...

Page 6: ...l of waste electrical and electronic equipment WEEE on the manufacturers of such equipment The companies are compelled to use the collected waste in an ecological friendly manner either by ecological...

Page 7: ...nsport button control in addition to an automation s Device Control Interface and a broadcast device s conventional transport controls When used in conjunction with an automation playout or ingest wor...

Page 8: ...ns for a JSC 2 Panel Specification Description Size 10 5 x 6 5 x 3 5 26 7 x 16 5 x 8 9 Weight 4 lbs 1 8 KG Power Requirements The JSC 2 comes with an external power supply brick universal 12 volt DC s...

Page 9: ...ned on both Button mapping for the JSC 2 panel is shown by the following diagram About Lamp States Buttons with a Lamp state Buttons dependent on showing a lamp state for proper User Interface operati...

Page 10: ...nsport status Stop Pause Play Forward Reverse Note Firmware version v2 14 or higher is required to use the Timecode display Firmware versions prior to v2 14 do not support jog shuttle querying and the...

Page 11: ...Shuttle Panel always controls the assigned bus machine for record buses while the Ad Hoc Ingest Window is not open Reconfigurable No First Button Second Row HOLD If a recording is in progress the cou...

Page 12: ...tton Third Row If one of the following contexts is applicable Play is commanded 1 Ad Hoc Ingest Window is open Source or Destination assigned 2 Record bus is displayed Destination assigned 3 VCP Windo...

Page 13: ...ssigned destination machine will be set to the current timecode reported by that bus or bus monitor machine Since all other machines are unaffected the Mark SOM command needs to be performed once for...

Page 14: ...ported by the destination machine and its SOM possibly set previously 2 If the Ad Hoc Ingest Window is active Source Assigned and the source assignment is from the schedule the calculated Duration is...

Page 15: ...segment is added to the loaded material Reconfigurable No Sixth Button Second Row OK If the Ingest Review Window is displayed and is waiting for acknowledgement acceptance or rejection of recording i...

Page 16: ...xt If a highlighted segment exists for the loaded material the segment SOM is set to the displayed timecode in the Device Control Area The segment s Duration and EOM are updated according to the curre...

Page 17: ...one of the following functions is invoked followed by updating the material duration according to the current context If a highlighted segment exists for the loaded material the segment EOM is set to...

Page 18: ...by the operator Configurations of other panels connected via serial connection e g the DAL Jog Shuttle Control Panel are stored across sessions in the DALingest INI file Cabling Pinouts A single JSC 2...

Page 19: ...Pin 3 RX Pin 2 TX Pin 8 RX Pin 3 RX Pin 7 TX Pin 4 GND Pin 1 GND Pin 6 RX Pin 2 TX USB to RS422 lead converter DB9F to DB9F The following USB to RS422 lead converter DB9F to DB9F pinouts are tested a...

Page 20: ...ations is not liable for any special indirect or consequential damages however caused To Return a Unit Follow this procedure when returning a defective unit for replacement Stage Action 1 Contact your...

Page 21: ...t Contact your Automation representative to order D Series Hardware components When ordering specify the components by Product Code Device Type Model Part Number Jog Shuttle Controller with Timecode D...

Reviews: