System
Maintenance
Section 6
24
Changing Grip Finger Assembly
The Grip Fingers should be changed every
100,000 cycles or when damaged.
1. Remove the Spark Shield (Figure 13)
2. Line the yellow retention collar up with the
mounting screws. Note the yellow retention
collar will be in the “unlocked” position.
3. Remove the 4 flat head screws (5/64 Hex Key)
via the access holes in the yellow retention collar
(Figure 17).
4. When all the screws have been removed, the yellow
retention collar assembly can be removed from the front
of the tool (Figure 18). The locking collar is a snug fit and
will require some effort to slide off the nose of the body housing. Set the
screws and these 3 pieces aside.
5. Using a T8 Torx driver remove
the two flat head screws holding
the Grip Finger Assembly in
place (Figure 19). Once the
screws are removed the grip
finger assembly will slide out as
shown.
6. To reinstall reverse the steps. It is
important to note the proper
order and orientation of the
components shown in Figure 18.
1) Align holes in Spark Shield
Retention Collar with the screws
as shown
2) Remove four screw around the
Spark Shield Retention Collar
Remove Spark Shield Retention Collar
components. It is easiest to use the yellow collar
to remove the locking collar. Note the
sequence and orientation of the components for
reinstallation.
Figure 17
Figure 18
Figure 19
3) Remove two Torx Screws
using a T8 Torx Driver
4) Pull Finger Assembly Straight Out
Summary of Contents for QuikLinx 10700
Page 9: ...Safety Precautions Section 1 8 Symbols and Definitions ...
Page 28: ...Section 2 Section 7 Exploded Diagram 27 Figure 21 1 9 8 12 13 4 5 7 6 10 11 3 2 ...
Page 30: ...Section 2 Section 7 Exploded Diagram 29 Figure 22 5 1 2 3 4 ...
Page 32: ...Please visit us on the web www imageindustries com twitter studwelding ...