background image

Page 2 of 18

Ilumiline SL User Manual Rev. 1

Before You Begin

Safety Notes

Read all the following safety notes before working with this product. These notes contain important 

information about the installation, usage, and maintenance of this product.

Personal Safety

Avoid direct eye exposure to the light source while the product is on.

Always disconnect the product from the power source before cleaning.

Always connect the product to a grounded circuit to avoid the risk of electrocution.

Do not touch the product’s housing when operating because it may be very hot.

Mounting and Rigging

The luminaire is intended for professional use only.

The product should be positioned so that prolonged staring into it at a distance closer than 3.3 ft 

(1 m) is not expected.

Do not submerge this product (IP66). Temporary outdoor operation is fine.

When using this product in an outdoor environment, use IP65 (or higher) rated power and data 

cables. Secure unused power and data ports with attached IP65 covers.

CAUTION: When transferring product from extreme temperature environments, (e.g., cold truck to warm, 

humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a 

failure, allow product to fully acclimate to the surrounding environment before connecting it to power.

Not for permanent outdoor installation in locations with extreme environmental conditions. This 

includes, but is not limited to:

Exposure to a marine/saline environment (within 3 miles of a saltwater body of water).

Locations where the normal high or low temperatures exceed the temperature ranges in this manual.

Locations that are prone to flooding or being buried in snow.

Areas where the product will be subjected to extreme radiation or caustic substances.

Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.

Make sure there are no flammable materials close to the product when operating.

When hanging this product, always secure to a fastening device using a safety cable.

Power and Wiring

Make sure the power cord is not crimped or damaged.

Always make sure you are connecting this product to the proper voltage in accordance with the 

specifications in this manual or on the product’s specification label.

To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely 

disconnect the product from power via breaker or by unplugging it.

Never connect this product to a dimmer pack or rheostat.

Make sure to replace the fuse with another of the same type and rating.

Never disconnect this product by pulling or tugging on the power cable.

If the external flexible cable or cord of this product is damaged, it shall be replaced with a special 

cable or cord exclusively available from the manufacturer or its service agent.

The light source contained in this luminaire shall only be replaced by the manufacturer, its service 

agent, or a similarly qualified person.

Operation

Do not operate this product if there is damage on the housing, lenses, or cables. Have the damaged 

parts replaced by an authorized technician at once.

Do not cover the ventilation slots when operating to avoid internal overheating.

The startup temperature range is -4 °F to 113 °F (-20 °C to 45 °C).

The operating temperature range is -40 °F to 113 °F (-40 °C to 45 °C).

The storage temperature range is -40 °F to 167 °F (-40 °C to 75 °C).

Do not start, operate, or store the product outside of the above temperature ranges.

In the event of a serious operation problem, stop using this product immediately!

Expected LED Lifespan

Over time, use and heat will gradually reduce LED brightness. Clustered LEDs produce more heat than 

single LEDs, contributing to shorter lifespans if always used at full intensity. The average LED lifespan is 

40,000 to 50,000 hours. To extend LED lifespan, maintain proper ventilation around the product, and limit 

the overall intensity.

This product contains no user-serviceable parts. Any reference to servicing in this User 

Manual will only apply to properly trained, certified technicians. Do not open the housing 

or attempt any repairs.

All applicable local codes and regulations apply to proper installation of this product.

If your Chauvet product requires service, contact Chauvet Technical Support. 

Summary of Contents for Ilumiline SL

Page 1: ...User Manual Model ID ILUMILINESL...

Page 2: ...purpose without written consent from Chauvet Document Printing For best results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 297 mm configure the...

Page 3: ...king 5 DMX Linking 6 Remote Device Management RDM 6 Beam Shaping Filters 6 Mounting 7 Orientation 7 Rigging 7 Procedure 7 4 Operation 8 Ilumicode RDM2go Control 8 Menu Map 8 Configuration DMX 9 Contro...

Page 4: ...se harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Any changes or modifications not expressly approved by the par...

Page 5: ...er and Wiring Make sure the power cord is not crimped or damaged Always make sure you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the p...

Page 6: ...t for fitting into available space while interchangeable easy to install beam spread filters to help the fixture adapt to various applications and throw distances Additionally the lime emitter allows...

Page 7: ...Ilumiline SL User Manual Rev 1 Introduction Product Dimensions 0 81 in 20 5 mm 2 59 in 65 9 mm 12 in 305 mm 1 18 in 30 mm 1 91 in 48 6 mm 2 68 in 68 2 mm 3 42 in 87 mm 3 04 in 77 1 mm 0 33 in 8 5 mm 0...

Page 8: ...ou can power link up to 46 products at 100 V up to 52 products at 120 V up to 75 products at 208 V up to 88 products at 230 V up to 88 products at 240 V or up to 92 products at 277 V Proprietary 2 in...

Page 9: ...anagement or RDM is a standard for allowing DMX enabled devices to communicate bi directionally along existing DMX cabling Check the DMX controller s User Manual or with the manufacturer as not all DM...

Page 10: ...oses Make sure that the structure onto which you are mounting the product can support the product s weight See the Technical Specifications for weight information When mounting the product overhead al...

Page 11: ...ear mode from fastest DIM1 to slowest DIM4 CALIB WHITE 1 11 RED 000 255 Determines the white balance for the color macros GREEN RGBTOW BLUE Determines the white balance when RGBTOW is active COOL PERS...

Page 12: ...annel Assignments and Values ARC1 3 Channels ARC1 D 4 Channels ARC2 4 Channels See the Starting Address section for the highest starting address you can select for each personality Make sure that the...

Page 13: ...000 255 0 100 5 Preset color 000 010 No function 011 020 Light Salmon 021 025 Scarlet 026 030 Flame Red 031 045 Dark Salmon 046 050 Sunset Red 051 060 CID To Tungsten 061 065 Soft Golden Amber 066 070...

Page 14: ...5 5000K 116 129 5001 5599K 130 5600K 131 144 5601 5999K 145 6000K 146 159 6001 6499K 160 6500K 161 174 6501 6999K 175 7000K 176 189 7001 7999K 190 8000K 191 204 8001 9999K 205 255 10000K 7 Strobe 000...

Page 15: ...21 025 Scarlet 026 030 Flame Red 031 045 Dark Salmon 046 050 Sunset Red 051 060 CID To Tungsten 061 065 Soft Golden Amber 066 070 Urban Sodium 071 080 LEE Yellow 081 085 Ice And A Slice 086 110 Dark Y...

Page 16: ...4500K 101 114 4501 4999K 115 5000K 116 129 5001 5599K 130 5600K 131 144 5601 5999K 145 6000K 146 159 6001 6499K 160 6500K 161 174 6501 6999K 175 7000K 176 189 7001 7999K 190 8000K 191 204 8001 9999K 2...

Page 17: ...Select the COLOR option 3 Select the calibration mode from OFF RGBTOW or UC Color Macro White Balance To adjust the color macro white balances 1 Go to the CALIB main level 2 Select the macro to adjus...

Page 18: ...uency To clean the product follow the instructions below 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove...

Page 19: ...tary 2 in 1 Proprietary 2 in 1 Power Connection Recommended Cable Total Max Cable Length Connector Max Diameter 3 7 ft 1 13 m hardwire to proprietary waterproof cable Power and data interface 14 AWG 2...

Page 20: ...uest Clearly label the package with an RMA number Iluminarc will refuse any product returned without an RMA number Before sending the product clearly write the following information on a piece of pape...

Page 21: ...uvetlighting eu Brookhill Road Industrial Estate Pinxton Nottingham UK Website www iluminarc com NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Benelux Address Stokstraat 18 Email BNLtech chauve...

Reviews: