Splicing Operation
Swift F1
Quick Reference Guide
Step
Description
Procedure
6
Cleaving
Operation
Automatic clever(CI-03) cleaves SM & MM
fibers at right angle. Open cleaver cover and
mount stripped and cleaned fiber holder into
the cleaving position.
CHECK THE FIBER IS
PROPERLY LYING IN PLACE
. Open chip-box
located at the right side of the F1.
WHEN
CLEAVE FIBER, FIRMLY PUSH CLEAVE COVER
.
After cleaving
BE CAREFUL THE FIBER FROM
ANY DUST OR CONTAMINANT
ANY DUST OR CONTAMINANT
.
7
Splicing
Operation
Mount cleaved fiber holders into both sides of
the splicer between the V-grooves and
electrodes.
CHECK THE FIBERS ARE PROPERLY
PLACED ON THE V-GROOVES
. Gently close the
wind protector. Press the ARC button to begin
splicing.
REDUCING SPLICE LOSS FIBERS MUST
BE PLACED ON CORRECT POSITIONS AND BE
CAREFUL THE FIBER FROM ANY DUST OR
CONTAMINANT
. Dispatch fibers from the
holders, and gently move the sleeve tube to
the spliced part of fiber. For ferrule, softly hold
the spliced part of fiber. For ferrule, softly hold
its cap and take out from fiber holders.
8
Sleeve Heater
Operation
Open heater cover and set the fiber into the
inside of heater.
FOR FERRULE, RED MAKE
MUST BE HEADING TO USER’S CHEST AND
MUST BE SET TO THE RIGHT-MOST POSITION
OF HEATER
. Press sleeve heater button in order
to active. Cooling fan is run to cool the sleeve
tube after 20 sec when completed the heating
process. Open the heater cover when cooling is
completed and take out the reinforced fiber.
9
Assembling
Connector
Operation
Take off ferrule cap and assemble it with boot
part. Assemble ferrule , jointed with boot part,
with grip part.
Contact :
Contact :
/ +82
/ +82--42
42--671
671--5609~11
5609~11