7. GENERAL NOTES
1. Before fitting the cylinder to a fire/smoke resisting door, the fire certification should be
examined to ensure conformity. Consult iLOQ sales representative for correct
configuration.
2. The iLOQ cylinders are successfully tested according the EN 1634-1 (EUFI29-
19003368) for 120 minutes in a hinged single leaf steel door.
3. This type of cylinder is developed for the use inside key switches which are prepared
for DIN half cylinder. Do not use the cylinder for other purposes resp. use cases.
4. Care should be taken to ensure that any seals or weather-stripping fitted to the complete
door assembly, does not inhibit the correct operations of the cylinder.
5. Care should be taken to ensure that no projection of the cylinder and associated parts,
can prevent the door swinging freely.
6. All components necessary for the specific installation should be fitted.
7. The key is to be kept securely so that only authorized person may have access.
8. In case of losing a key, blacklisting of the lost key shall be done with the iLOQ Manager
software and affected locks shall be reprogrammed.
9. Especially in industrial areas or near the sea, impurities can cause deposits in the form
of rust and attacked the material. This equipment should be cleaned and maintained
frequently.
10. Cylinder will lock, for security reasons, itself after 10 seconds, the key can then be
removed by turning it back to the 12 o’clock position (either clockwise or anti-clockwise).
11. The cylinder has an operating angle of +/- 90°around the neutral position
,
do not try to
overturn the cam.
12. In case of problems with functionality please check following points:
Check, if the locking cylinder is damaged.
Check, if foreign particles are present in keyway.
A wrongly located cylinder within the lock case due to incorrectly mounted
furniture.
A defective mortise lock.
Incorrectly mounted locking plates.
A warped door etc.