iLoq D5S.5X0.SB User Manual Download Page 3

 

 

 

Page 3 of 7

 

 

 

1. BEFORE INSTALLING 

1.  These instructions should be carefully followed during installation. These instructions and 

any maintenance instructions should be passed on by the installer to the user. 

2.  iLOQ D5S cylinders must be installed and used carefully without excessive force. 
3.  The product should not be modified in any way except in accordance with the modifications 

described in these instructions. 

4.  Care should be taken to ensure that any seals or weather-stripping fitted to the complete 

door assembly, does not inhibit the correct operations of D5S cylinder. 

5.  Care should be taken to ensure that no projection of the D5S cylinder and associated parts, 

can prevent the door swinging freely. 

6.  All  components necessary for the  specific installation should be fitted in order to ensure 

compliance with EN 15684 standard. 

7.  The cylinder must project less than 1 mm on outside of the door to ensure proper operation. 
8.  No liability is accepted for damage to the doors or components due to incorrect installation. 
9.  Before  fitting  D5S  cylinder  to  a  fire/smoke  resisting  door,  the  fire  certification  should  be 

examined, to ensure conformity. 

10. D5S.5x0 cylinder is only available in one length with 30/10 mm. 
11. This type of cylinder is developed for the use inside key switches which are prepared for 

DIN half cylinder with a length of  30-10 mm.  Do not use the cylinder for  other  purposes 
resp. use cases. 

12. The  cylinder  has  an  operating  angle  of  +/-  90°around  the  neutral  position

do  not  try  to 

overturn the cam. 

13. If  there  are  any  deviations  from  the  contents  in  foreign  language  versions  of  the 

documentation, the English original shall apply in case of doubt. 

14. We reserve the right to make modifications or further technical developments without further 

notice. 

2.  AFTER INSTALLATION 

Test the cylinder functionality after installation to ensure that it does not prevent the key switch from 
working properly. 

 

3. CARE 

After 5-10,000 usages, clean contact rolls lightly with lint-free cotton pad. Spray small amount of 
high-quality lock oil i.e. CRC lock oil (with PTFE) onto contact rolls. 
 
In the case the cylinder is not working in an appropriate way anymore, we recommend cleaning the 
cylinder with e.g. compressed air spray or similar.

 

 
 

 