background image

SECTION 7    Maintenance

 

 
The Aerostat XC has been designed with low maintenance in mind. The only regular 
maintenance suggested is emitter point cleaning, ion balance checking and ion output 
checking.  Emitter point cleaning takes only seconds with SIMCO’s patented point 
cleaner.  The Aerostat XC contains a patented balancing circuit that is inherently self 
balancing.  This circuit compensates for dirt build-up on emitters, emitter point wear, line 
voltage fluctuations and variations in air velocity.  Scheduled checking of the ion output 
and balance should be considered to assure quality audit requirements. 

 
 

CAUTION!  ELECTRICAL SHOCK HAZARD!   

Do not insert objects through intake or outlet grille.

 

 

 
7.1  Emitter Cleaning 
To clean the ion emitters, simply sweep the emitter cleaner back and forth once across 
the ionized air outlet. Recommended frequency of cleaning is once a week. 
 
7.2  Air Inlet and Outlet Cleaning 
The air inlet grille on the rear of the unit and the ionized air outlet should remain clean to 
prevent restriction of air flow.  They can be cleaned with a soft brush or vacuum. 
 
7.3  Optional Air Filter Cleaning 
Remove the air filter from the rear of the unit by sliding the aluminum frame of the filter 
towards the rear of the unit. Rinse the filter in plain water while gently squeezing.  If the 
dirt is stubborn, wash the filter in mild soap and water then rinse.  Blot the filter dry with 
paper towels and allow to dry.  Reinstall filter on air inlet by sliding it under brackets 
from rear of the unit.  

IMPORTANT

: If an air filter is used, clean the air filter regularly. 

 
7.4  Ion Output Check 
To test the unit for ion output, the use of a charge plate monitor such as the SIMCO  
EA-4 is recommended.  Discharge times can be measured and checked against the Ion 
Output tables in Section 3, Specifications.  If a charge plate monitor is not available, but 
a static meter such as a SIMCO handheld electrostatic fieldmeter is available, ion output 
may be checked with the following procedure.  Take a piece of plastic and rub it with 
cloth until a static charge can be read with the static meter.  Turn on the Aerostat XC.  
Hold the plastic one foot away from the ionized air outlet for five seconds.  Remove the 
plastic from the ionized air stream and measure the static charge.  The plastic should be 
neutralized. 
 
If no instrumentation is available, the XC’s operation can be verified with the following 
procedure. Tear off about a 10-inch length of Scotch® brand (or equivalent) transparent 
tape. Approach the non-adhesive side of the tape with your free hand and note the 
electrostatic attraction of the tape to your hand.  Pass the tape through the ionized air 
stream approximately 1 foot from the unit and again approach the non-adhesive side of 
the tape with your free hand. If the tape has been neutralized, it will not attract. 
 

 

Summary of Contents for 4002612

Page 1: ...roblem It can be applied in inspection testing and assembly environments The Aerostat XC can also be used where static electricity causes problems such as attraction of dirt to product misalignment of...

Page 2: ...el ion emitters which results in an intense alternating electric field at the tip of the emitters It is this intense electric field that introduces alternating polarity ions into the air flow The shap...

Page 3: ...enter line of air stream Air Flow Characteristics 3 x 6 Area Coverage Heated Air Temperature Fan Speed Above Ambient where applicable Low 11 F 6 C Medium 9 5 C High 7 F 4 C Measured 6 in front of unit...

Page 4: ...rom 1000 volts to 100 volts Note Discharge times for high speed are 10 longer for 230 V 50 Hz SECTION 4 Safety 4 1 Read all instructions before proceeding with installation or operation Failure to fol...

Page 5: ...s an optional air filter kit part number 5050281 is available The air filter kit contains user installed brackets and an air filter that can be cleaned and reused The Aerostat XC should be placed appr...

Page 6: ...neutralize each other Positive and negative ions are electrostatically attracted to each other When they contact the charge transfers and the ions recombine With high air velocity the ions travel furt...

Page 7: ...s stubborn wash the filter in mild soap and water then rinse Blot the filter dry with paper towels and allow to dry Reinstall filter on air inlet by sliding it under brackets from rear of the unit IMP...

Page 8: ...on Balance in Section 3 Specifications Do not try to determine ion balance by holding a static meter in the ionized air stream This will result in a meaningless reading 7 6 Calibration The Aerostat XC...

Page 9: ...eater ionizer and brush 6 4670700 Brush 7 4401510 Ionizer Duct Standoff 2 required 8 4103940 Line Cord Assembly 120 V 8 4104035 Line Cord Assembly 230 V 9 4610699 Illuminated Rocker Switch 120 V 9 461...

Page 10: ...where state laws override This warranty extends to the original purchaser and is not transferable No person agent distributor dealer or company is authorized to change modify or amend the terms of thi...

Reviews:

Related manuals for 4002612