background image

 

(39.1 cm W x 11.4 cm H x 20.6 cm D) 

 
Bench Stand Feet: 

Nonconductive, Nonstaining Polymer 

 
Optional Air Filter: 

30 PPI Open Cell Polyurethane Foam 

 
Ion Balance (offset voltage): 

0V + 5 

 
Ion Output (discharge time): 
 

 

Fan Speed - High 

1 ft. 

2 ft. 

3 ft. 

4 ft. 

 

5  5.5 6.5 8.5 

12 

inches 

 1.5 

2.5 

5.5 

Center 

Line 

 

5  5.5 6.5 8.5 

12 

inches 

 
 

Fan Speed - Medium  1 ft. 

2 ft. 

3 ft. 

4 ft. 

 

6 7 9 11  12 

inches 

 

1.7 

3.5 

 7 

Center Line 

 

6 7 9 11  12 

inches 

 
 

Fan Speed - Low 

1 ft. 

2 ft. 

3 ft. 

4 ft. 

  

9 10 

12  12 

inches 

 

 

  7 

  9 

Center Line 

  

9 10 

12  12 

inches 

 
Offset voltage and discharge time determined as per ESD Association Standard No. 3 
using 6” x 6”, 20 pF plate (charge plate monitor).  Discharge times are in seconds from 
1000 volts to 100 volts. 

 
Note:

  Discharge times for high speed are 10% longer for 230 V, 50 Hz. 

 
 
SECTION 4   Safety 

 
4.1  Read all instructions before proceeding with installation or operation. Failure to 

follow instructions may result in damage to the ionizer and/or personal injury. 

 
4.2  This unit is supplied with a 3-prong grounding plug, which must be inserted in an 

appropriate, properly wired, and grounded receptacle. Do not defeat the electrical 
ground, grounding and proper wiring are required for proper operation. 

 
4.3  Keep the unit dry. Do not operate the ionizer in a flammable, volatile or explosive 

atmosphere. 

 
4.4  Do not insert objects through the unit’s intake or outlet grilles. Damage to the 

ionizer and/or personal injury may result. 

 
4.5  Do not ground or make electrical connections of any kind to the unit’s metal fan 

guards located on the intake and output. 

 

 

Summary of Contents for 4002612

Page 1: ...roblem It can be applied in inspection testing and assembly environments The Aerostat XC can also be used where static electricity causes problems such as attraction of dirt to product misalignment of...

Page 2: ...el ion emitters which results in an intense alternating electric field at the tip of the emitters It is this intense electric field that introduces alternating polarity ions into the air flow The shap...

Page 3: ...enter line of air stream Air Flow Characteristics 3 x 6 Area Coverage Heated Air Temperature Fan Speed Above Ambient where applicable Low 11 F 6 C Medium 9 5 C High 7 F 4 C Measured 6 in front of unit...

Page 4: ...rom 1000 volts to 100 volts Note Discharge times for high speed are 10 longer for 230 V 50 Hz SECTION 4 Safety 4 1 Read all instructions before proceeding with installation or operation Failure to fol...

Page 5: ...s an optional air filter kit part number 5050281 is available The air filter kit contains user installed brackets and an air filter that can be cleaned and reused The Aerostat XC should be placed appr...

Page 6: ...neutralize each other Positive and negative ions are electrostatically attracted to each other When they contact the charge transfers and the ions recombine With high air velocity the ions travel furt...

Page 7: ...s stubborn wash the filter in mild soap and water then rinse Blot the filter dry with paper towels and allow to dry Reinstall filter on air inlet by sliding it under brackets from rear of the unit IMP...

Page 8: ...on Balance in Section 3 Specifications Do not try to determine ion balance by holding a static meter in the ionized air stream This will result in a meaningless reading 7 6 Calibration The Aerostat XC...

Page 9: ...eater ionizer and brush 6 4670700 Brush 7 4401510 Ionizer Duct Standoff 2 required 8 4103940 Line Cord Assembly 120 V 8 4104035 Line Cord Assembly 230 V 9 4610699 Illuminated Rocker Switch 120 V 9 461...

Page 10: ...where state laws override This warranty extends to the original purchaser and is not transferable No person agent distributor dealer or company is authorized to change modify or amend the terms of thi...

Reviews: