(39.1 cm W x 11.4 cm H x 20.6 cm D)
Bench Stand Feet:
Nonconductive, Nonstaining Polymer
Optional Air Filter:
30 PPI Open Cell Polyurethane Foam
Ion Balance (offset voltage):
0V + 5
Ion Output (discharge time):
Fan Speed - High
1 ft.
2 ft.
3 ft.
4 ft.
5 5.5 6.5 8.5
12
inches
1.5
2.5
4
5.5
Center
Line
5 5.5 6.5 8.5
12
inches
Fan Speed - Medium 1 ft.
2 ft.
3 ft.
4 ft.
6 7 9 11 12
inches
1.7
3.5
5
7
Center Line
6 7 9 11 12
inches
Fan Speed - Low
1 ft.
2 ft.
3 ft.
4 ft.
8
9 10
12 12
inches
2
5
7
9
Center Line
8
9 10
12 12
inches
Offset voltage and discharge time determined as per ESD Association Standard No. 3
using 6” x 6”, 20 pF plate (charge plate monitor). Discharge times are in seconds from
1000 volts to 100 volts.
Note:
Discharge times for high speed are 10% longer for 230 V, 50 Hz.
SECTION 4 Safety
4.1 Read all instructions before proceeding with installation or operation. Failure to
follow instructions may result in damage to the ionizer and/or personal injury.
4.2 This unit is supplied with a 3-prong grounding plug, which must be inserted in an
appropriate, properly wired, and grounded receptacle. Do not defeat the electrical
ground, grounding and proper wiring are required for proper operation.
4.3 Keep the unit dry. Do not operate the ionizer in a flammable, volatile or explosive
atmosphere.
4.4 Do not insert objects through the unit’s intake or outlet grilles. Damage to the
ionizer and/or personal injury may result.
4.5 Do not ground or make electrical connections of any kind to the unit’s metal fan
guards located on the intake and output.