background image

4.6  A factory-qualified service technician must perform component service and repairs. 

Please contact SIMCO Customer Service for information. 

 

 
SECTION 5   Installation

 

 
Carefully remove the equipment from the carton and inspect contents. Empty the carton 
to insure that small parts are not discarded.  If any damage has occurred during 
shipment, notify the local carrier at once.  A report should also be forwarded SIMCO, 
2257 North Penn Road, Hatfield PA 19440, Phone (215) 822-2171. See Section 9 for 
Return Shipment information. 
 
The Aerostat XC is designed for portable or permanent operation. It is supplied with a 
bench stand; an optional pedestal mount (part number 5050282) is available. The 
bench stand can be used for portable operation or bolted to a sturdy flat surface such as 
a wall or under a shelf.  If the bench stand is bolted in place, use 5/16-inch diameter 
screws or bolts to secure it. 
 
For extremely dirty environments, an optional air filter kit (part number 5050281) is 
available. The air filter kit contains user-installed brackets and an air filter that can be 
cleaned and reused. 
 
The Aerostat XC should be placed approximately 1 to 3 feet from the critical work area 
or objects to be neutralized. It should be positioned to cover as much of the area as 
possible with the ionized air stream.  The air stream can be directed upward or 
downward by tilting the unit on the stand. Tightening the lock knobs on each side of the  
unit secure it in position. 
 
The Aerostat XC, part number 4002612, requires 120 VAC 60 Hz for proper operation.  
The unit must be grounded for safe operation.  Plug the unit into a standard 3-terminal 
grounded receptacle. 
 
The Aerostat XC, part number 4002667, requires 220-230 VAC 50 Hz. for proper 
operation. The unit must be grounded for safe operation. The unit comes with line cord, 
without plug.  A plug must be installed on the line cord for operation. Installation of the 
plug must be performed by qualified service personnel. The color code for wiring the 
plug is as follows: Brown - Line; Blue - Neutral; Green/Yellow - Ground. 
 

 

Summary of Contents for 4002612

Page 1: ...roblem It can be applied in inspection testing and assembly environments The Aerostat XC can also be used where static electricity causes problems such as attraction of dirt to product misalignment of...

Page 2: ...el ion emitters which results in an intense alternating electric field at the tip of the emitters It is this intense electric field that introduces alternating polarity ions into the air flow The shap...

Page 3: ...enter line of air stream Air Flow Characteristics 3 x 6 Area Coverage Heated Air Temperature Fan Speed Above Ambient where applicable Low 11 F 6 C Medium 9 5 C High 7 F 4 C Measured 6 in front of unit...

Page 4: ...rom 1000 volts to 100 volts Note Discharge times for high speed are 10 longer for 230 V 50 Hz SECTION 4 Safety 4 1 Read all instructions before proceeding with installation or operation Failure to fol...

Page 5: ...s an optional air filter kit part number 5050281 is available The air filter kit contains user installed brackets and an air filter that can be cleaned and reused The Aerostat XC should be placed appr...

Page 6: ...neutralize each other Positive and negative ions are electrostatically attracted to each other When they contact the charge transfers and the ions recombine With high air velocity the ions travel furt...

Page 7: ...s stubborn wash the filter in mild soap and water then rinse Blot the filter dry with paper towels and allow to dry Reinstall filter on air inlet by sliding it under brackets from rear of the unit IMP...

Page 8: ...on Balance in Section 3 Specifications Do not try to determine ion balance by holding a static meter in the ionized air stream This will result in a meaningless reading 7 6 Calibration The Aerostat XC...

Page 9: ...eater ionizer and brush 6 4670700 Brush 7 4401510 Ionizer Duct Standoff 2 required 8 4103940 Line Cord Assembly 120 V 8 4104035 Line Cord Assembly 230 V 9 4610699 Illuminated Rocker Switch 120 V 9 461...

Page 10: ...where state laws override This warranty extends to the original purchaser and is not transferable No person agent distributor dealer or company is authorized to change modify or amend the terms of thi...

Reviews: