18

Disconnect the machine from the power source and take 

the following steps before restarting and operating the 

machine:

•  check for damage

•  replace or repair damaged parts

•  check for loose parts and tighten them

When working with this machine, do not use spare parts 

other than those recommended by us. Using spare parts 

not recommend by us can result in serious injuries to 

persons or damage to the machine.

MAINS CONNECTION

 DANGER!

Operation is only allowed with a safety switch against 

stray current (RCD max. stray current of 30mA).

Before use check machine, cable, and plug for any dama-

ges or material fatigue. Repairs should only be carried out 

by authorised Service Agents.
Insert the plug of the electrical cable in a socket of suitable 

shape, voltage and frequency complying with current 

regulations.
Keep the connection and extension cables away from 

dangerous moving parts to avoid damaging them.
Only use splash proof extension cables approved for 

outdoor purposes. The stranded wire cross-sectional area 

of the extension cable must be at least 1.5 mm

2

 for cables 

up to 25 m and 2.5 mm

2

 for cables above 25 m.

Only plug-in when machine is switched off .
The device is only intended for use on premises that have 

a continuous current carrying capacity of >=100 A per 

phase and are supplied from a electrical grid with a rated 

voltage of 400/230V.
If necessary, please consult your electricity company to 

ensure that the continuous current carrying capacity of 

the mains at the connection point is suffi  cient for connec-

ting the device.

 WARNING

WARNING! Electric shock! There is a risk of an injury 

caused by electric shock!

Do not use the device if the cable or plug is damaged or 

worn.
If the cable is damaged during use, it must be discon-

nected from the mains supply immediately. Do not touch 

the cable until it has been disconnected from the mains.

Do not connect a damaged cable to the power supply 

and do not touch a damaged cable before disconnecting 

it from the power supply, as damaged cables can lead to 

contact with active parts.

SPECIFIED CONDITIONS OF USE

The scarifi er & raker may only be used for scarifying and 

removing moss or for raking leaves, moss or weeds from 

lawns in residential and hobby gardens – depending on 

the attached roller.
The device may not be used in commercial applications.

 WARNING

Risk of injury
Rotating blades may lead to serious injuries by cutting 

or amputating parts of the body.

•  Be careful to avoid injury by the cutting tools. Careful 

appliance handling reduces the risk of injury by knife.

•  Do not touch any dangerous moving parts before 

the machine has been disconnected from the power 

supply and the moving parts have come to a complete 

standstill.

•  All protection covers and safety devices must be correct-

ly attached to operate the device.

•  Never use the machine with a damaged cover or protec-

tive device or without cover or protective devices.

Do not use this product in any other way as stated for 

normal use. Not observing general regulations in force 

and instructions from this manual does not make the 

manufacturer liable for damages.
Please note that permissible uses for the tool could be 

limited by national regulations. It is necessary to comply 

with the regulations applicable in the country where the 

device is used.
Do not use the device near fl ammable liquids or gases. 

Risk of fi re and explosion in case of short circuit.

GB

   ENGLISH

Summary of Contents for 80201020

Page 1: ...fter 10 GB Translation of the original instructions Electric Lawn Scarifier and Raker 16 FR Traduction du mode d emploi d origine Scarificateur et mousseur lectrique 22 IT Traduzione del Manuale d Us...

Page 2: ...1 2 4 5 6 7 3...

Page 3: ...1 I START STOP III VI V II IV...

Page 4: ...2 I 1 2...

Page 5: ...3 3 4 I...

Page 6: ...4 II 1 2 3...

Page 7: ...5 III 1 Max 7 5 cm 4 0 cm...

Page 8: ...6 IV 0 10 mm 1 2 mm 2 0 mm 3 4 mm 4 8 mm 6 mm 0 0 mm 1 4 mm 2 8 mm 3 12mm 4...

Page 9: ...7 V 1 1 START STOP 2 4 1 3 ON 3 ON 3 ON...

Page 10: ...8 V...

Page 11: ...9 III 1 2 VI...

Page 12: ...ch die Zeiten ber cksichtigt werden in denen das Ger t abgeschaltet ist oder zwar l uft aber nicht tats chlich im Einsatz ist Dies kann die Schwingungsbelastung ber den gesamten Arbeitszeitraum deutli...

Page 13: ...zu Geh rsch digungen f hren Geh rschutz tragen Eine gewisse L rmbelastung durch dieses Ger t ist nicht vermeidbar Verlegen Sie l rmintensive Arbeiten auf zu gelassene und daf r bestimmte Zeiten Halten...

Page 14: ...n besch digt werden NETZANSCHLUSS GEFAHR Der Betrieb ist nur mit Fehlerstrom Schutzschalter RCD max Fehlerstrom 30mA zul ssig Vor jedem Gebrauch Ger t Anschlusskabel Akkupack Verl ngerungskabel und St...

Page 15: ...rnung Achtung Schutzbrille tragen Geh rschutz tragen Vor allen Einstellungs Reinigungs und War tungsarbeiten Ger t ausschalten und von der Enegiezufuhr trennen Betriebsanleitung lesen Bewahren Sie all...

Page 16: ...ch den Gebrauch anderer Ersatzteile k nnen Unf lle f r den Benutzer entstehen F r hieraus resultierende Sch den haftet der Hersteller nicht Falls Sie Zubeh r oder Ersatzteile ben tigen wenden Sie sich...

Page 17: ...tungsverfahren nach Anhang V Richtlinie 2000 14 EG Gemessener Schallleistungspegel 100 55 dB A Garantierter Schallleistungspegel 104 dB A Das Baujahr ist auf dem Typenschild aufgedruckt und zus tzlich...

Page 18: ...use This may significantly reduce the vibratory load over the total working period Identify additional safety measures to protect the operator from the effects of vibration such as maintain the tool a...

Page 19: ...ng smooth whenever the appliance is to be put into operation Replace worn or damaged blades and bolts in sets to preserve balance Damaged or illegible security stickers must be replaced Do not use the...

Page 20: ...jury caused by electric shock Do not use the device if the cable or plug is damaged or worn If the cable is damaged during use it must be discon nected from the mains supply immediately Do not touch t...

Page 21: ...tangled or damaged The tines continue to run after the engine has been switched off Keep connection and extension cables away from the tines Warning against sharp knives Knives keep running for a sho...

Page 22: ...spare parts STORAGE The appliance must be stored in a dry place and pro tected from frost Lock the device in a proper place to protect it from unauthorised use Store idle power tools out of the reach...

Page 23: ...Measured sound power level 100 55 dB A Guaranteed sound power level 104 dB A The year of manufacture is printed on the nameplate and can be additionally retrieved via the consecutive serial number M...

Page 24: ...tions pendant une certaine dur e de travail il faut galement tenir compte des temps d arr t ou de marche vide de l appareil Cela peut entra ner une r duction sensible du volume de charge par vibration...

Page 25: ...ive Les nuisances sonores caus es par cet appareil sont in vitables Effectuez les travaux tr s bruyants aux horaires autoris s et destin s cet effet Observez le cas ch ant des p riodes de pause et lim...

Page 26: ...ourraient subir de graves blessures et l appareil pourrait tre endommag BRANCHEMENT SUR SECTEUR DANGER Le fonctionnement est autoris uniquement avec un disjoncteur diff rentiel RCD courant de d faut m...

Page 27: ...streindre l utilisation de l appareil Il est n cessaire de respecter les r gles en vigueur dans le pays d utilisation du transpalette N utilisez pas l appareil proximit des liquides ou gaz inflammable...

Page 28: ...hiffon humide en veillant d abord ce que la fiche soit d branch e de la prise lectrique Veillez ce que tous les crous boulons et vis soient bien serr s pour vous assurer que le mat riel est en bonne c...

Page 29: ...ves en mati re de bruit 2011 65 UE directive RoHS modifications inclues Pour mettre en pratique dans les r gles de l art les prescriptions en mati re de s curit et de sant stipul es dans les Directive...

Page 30: ...degli apparecchi elettrici E adatto anche alla pre valutazione del carico dalle vibrazioni Per una valutazione precisa della sollecitazione da vibrazioni si deve tenere conto anche dei tempi in cui l...

Page 31: ...udito Un certo inquinamento acustico inevitabile durante l impiego di questo attrezzo Concentrare i lavori partico larmente rumorosi negli orari consentiti e previsti per tali attivit Rispettare event...

Page 32: ...OLLEGAMENTO ALLA RETE PERICOLO L esercizio ammesso solo con l interruttore di sicurezza alla corrente falsa RCD max corrente falsa 30 mA Prima di ogni utilizzo controllare che il cavo di alimentazi on...

Page 33: ...protezione Utilizzare le protezioni dell udito Prima di eseguire qualsiasi lavoro di installazio ne pulizia e manutenzione spegnere il disposi tivo e staccarlo dall alimentazione elettrica Prima dell...

Page 34: ...responsabilit per i danni ne derivanti Nel caso in cui abbiate necessit di accessori o pezzi di ricambio siete pregati di rivolgervi alla nostra assistenza DEPOSITO Immagazzinare la macchina in local...

Page 35: ...o di potenza sonora garantito 104 dB A L anno di costruzione riportato sulla targhetta dell apparecchio ed individuabile tramite il numero di serie progressivo M nster 2020 03 11 Matthias Fiedler Seni...

Page 36: ...o en los que no se utilice a pesar de estar en marcha Esto puede reducir la carga de vibraci n significativamente a lo largo de todo el tiempo de trabajo INDICACIONES DE SEGURIDAD ADVERTENCIA Este ap...

Page 37: ...residuales no evidentes Compruebe cuidadosamente el rea donde se vaya a utilizar la m quina y retire cualquier objeto que pueda ser atrapado y proyectado como piedras ramas cables seres vivos etc Ant...

Page 38: ...e alimentaci n a una toma de corriente de forma tensi n y frecuencia adecuadas y que cumpla con la normativa vigente Mantenga los cables de conexi n y de extensi n alejados de las piezas m viles pelig...

Page 39: ...S MBOLOS Advertencia Atenci n Llevar gafas de protecci n Usar protecci n auditiva Antes de realizar cualquier trabajo de ajuste limpieza y mantenimiento apague el disposi tivo y descon ctelo de la fu...

Page 40: ...defectos de mantenimiento y cuidado pueden provocar accidentes y lesiones imprevisibles Solo el personal cualificado deber llevar a cabo las repa raciones y los trabajos no descritos en este manual Ut...

Page 41: ...es t cnicas EN 60335 1 2012 A13 2017 EN 50636 2 92 2014 EN 62233 2008 EN 55014 1 2017 EN 55014 2 2015 EN IEC 61000 3 2 2019 EN 61000 3 11 2000 EN 50581 2012 AfPS GS 2014 01 PAK Proceso de concesi n de...

Page 42: ...oles Girona 34 902 555 677 34 972 57 36 00 info yaros es Horario de 09 00 a 13 00 y 15 00 a 18 00 IN l Agritech Floritech Inc 206 B Rajindera Arihant Tower B 1 Community Centre Janak Puri New Delhi 11...