EN // 51
USER’S MANUAL
EN
Technical assistance
Before calling for service, check the information regarding troubleshooting in the following chart:
Problem
Possible cause
Correcctions
Stove throws
smoke
- Wet or green wood
- Chimney dirty or blocked
- Adverse weahter conditions
- Add dry wood
- Clean the chimney
- Vacuum the burning chamber
Inconsistent
burning or
ineffective
- Wet or green wood
- Chimney dirty or blocked
- Insufficient wood or too dense
- Dirt in the deflector
- Use dry wood
- Keep the air intake regulator
open at maximum until the
fire is well lit
The glass
gets dirty
- Wet or green wood
- Use dry wood
- Keep the air intake regulator
open at maximum until the
fire is well lit
The wood
burns too
fast
- Insufficient wood
- Air intake regulator in firing position
- Poorly adjusted / sealed door
- Damaged sealing cord
- Add dry wood
- Reduce the intake air
- Adjust the closure
- Sealing cord replacement
Ventilator
does not
work
- The stove isn’t hot enough
- There is no power supply
- Put more wood
- Check the electrical
ventilator plug is connected
- General house electricity fail
Ventilator
runs with
lower flow
- Dirt on the lower flow grate
- Clean the lower grate
Summary of Contents for INTRA S 100
Page 1: ......
Page 2: ......
Page 4: ...4 USER S MANUAL NOTAS NOTES ...
Page 5: ...PT PORTUGUÊS MANUAL DO UTILIZADOR ...
Page 21: ...ES ESPAÑOL MANUAL DEL USUARIO ...
Page 37: ...EN ENGLISH USER S MANUAL ...
Page 54: ...MANUAL DO UTILIZADOR MANUAL DEL USUARIO USER S MANUAL ...