Piling of the stones  

 
Wash the stones before piling. Check the safety distances are correct and the heater is attached on the back strip. 
Check the maximum amount of stones for the heater model you are using from page 9. The heating elements 
must be well covered. Piles stones so thy cover the elements with at least 5 centimetres on all sides, that the 
elements are not in contact with one another or the mesh frame. In normal use, olivine, olivine-dolerite and 
peridotite stones are recommended, in sizes smaller than 10 cm in diameter. The stones should not be placed too 
tightly together allowing for free airflow between the stones. In communally or publicly used saunas we 
recommend the use of ceramic Kerkes stones around the heating elements (www.kerkes.fi). Kerkes stones 
support and help preserve the resistors and they do not disintegrate prematurely due to high temperature 
changes. Note that the use of soapstone and natural stones is allowed only on the outer edges and on the top of 
the heater. 

During use, pay attention that the surface level of the stones drops. Check twice or thrice a year that the heating 
elements have not become exposed, add stones if necessary. Replace used stones periodically, as often as 
necessary. Check once a year the condition of the stones, and replace if needed.   

 

 

Table of heater models 

 

 
 
Heater 

Sauna 

size 

Height of 

heater 

Diameter 

of heater 

Max stone 

capacty 

Power  

Fise 

 

Wire 

Pillar IKI 4,5 kW 

3-6 m³ 

120 cm 

26 cm 

80 kg 

4,5 kW 

3x10A 

5x1,5 mm² 

Pillar IKI 6 kW 

5-9 m³ 

140 cm 

26 cm 

100 kg 

 6 kW 

3x10A 

5x1,5 mm² 

Corner IKI 6,6 kW 

5-10 m³ 

102 cm 

45 cm 

130 kg 

6,6 kW 

3x10A 

5x1,5 mm² 

Pillar IKI 7,5 kW 

7-12 m³ 

105 cm 

34 cm 

140 kg 

7,5 kW 

3x16A 

5x2,5 mm² 

Pillar IKI 9 kW 

8-16 m³ 

120 cm 

34 cm 

150 kg 

9 kW 

3x16A 

5x2,5 mm² 

Pillar IKI 10 kW 

10-18 m³ 

125 cm 

34 cm 

170 kg 

10 kW 

3x16A 

5x2,5 mm² 

 
 
 

Safety distances 

to inflammable surface materials (eg. wall panelling and benches) 

 
 
Heater 

 

Front 

 

Side 

 

Back 

 

Up 

Pillar IKI 4,5 kW 

10 cm 

10 cm 

10 cm 

60 cm 

Pillar IKI 6 kW 

10 cm 

10 cm 

10 cm 

60 cm 

Corner IKI 6,6 kW 

10 cm 

80 cm 

Pillar IKI 7,5 kW 

10 cm 

10 cm 

10 cm 

80 cm 

Pillar IKI 9 kW 

10 cm 

10 cm 

10 cm 

80 cm 

Pillar IKI 10 kW 

10 cm 

10 cm 

10 cm 

80 cm 

 

* Corner IKI can be installed in the corner  
 
 

 

Summary of Contents for Pillar IKI 10 kW

Page 1: ...Instructions for installation and use IKI electric heaters with Finlandia control unit Pillar IKI 4 5 kW Pillar IKI 6 kW Pillar IKI 7 5 kW Pillar IKI 9 kW Pillar IKI 10 kW 10 2016...

Page 2: ...any other purpose is prohibited Before you begin installing the heater pay attention to the following points Beware of the sharp edges of the stainless steel mesh Use a long sleeved shirt and protecti...

Page 3: ...control panel 9 Installation of the control panel 10 Piling of the stones 11 Table of heater models 11 Safety distances 11 Requirements for water quality 12 Circuit diagram 13 Supporting the heater ag...

Page 4: ...gs down 4 button This button allows you to adjust the settings up 5 Light indicator Use this button to switch on the lights on the heater when applicable A second push turns the lights off 6 The devic...

Page 5: ...s or buttons to change the pre settings If no buttons are pressed for 10 seconds the home menu returns You can exit the settings mode by pressing the menu button repeatedly 2 When the display shows he...

Page 6: ...tor light will illuminate The right hand lower corner in the display will show a decimal point to indicate that the heat resistors are switched on If the timer is set pressing the on off button will s...

Page 7: ...tch is only operating switch The electric current is on if it is attached to the network The control unit should not be located in a shower room or other humid place Step by step 1 Choose the location...

Page 8: ...s 12 After piling the stones affix the heater to the wall using the steel supporters Check that the heater stands steady before use 13 We recommend the use of safety railings around the heater However...

Page 9: ...not cut the wire on the thermostat side The sensor will not function if the wires are extended or reconnected If the wire needs to be shortened do the clipping on the side of the adapter or contact te...

Page 10: ...wires from the heater along the bottom of the panel to the hole and through to the box 5 Attach the wires to the unit as above Press the unit down to the box The unit is affixed with two steel pins 6...

Page 11: ...d only on the outer edges and on the top of the heater During use pay attention that the surface level of the stones drops Check twice or thrice a year that the heating elements have not become expose...

Page 12: ...type Effect Recommendation Humus concentration Color taste precipitates 12 mg l Iron concentration Color smell taste precipitates 0 2 mg l Hardness most important substances are manganese Mn and lime...

Page 13: ...Instructions for installation and use IKI electric heaters with Finlandia control unit Page 13 Circuit diagram...

Page 14: ...use IKI electric heaters with Finlandia control unit Page 14 Supporting the heater against a wall Option 1 corner installation Option 2 wall installation Supporting beam Supporting beam Supporting be...

Page 15: ...placement part must be carried out by a mechanic that has been approved by the manufacturer The manufacturer is not liable to reimburse any costs due to the removal of the faulty part or the installat...

Page 16: ...s Starsauna Ltd the manufacturer assures a warranty to its products as stipulated here The warranty period is 24 months from the day of delivery in privately used saunas Sales receipt confirmation of...

Page 17: ...e parts according to a valid price list The claim for compensation must be delivered in writing to the manufacturer with attached warranty certificate for the sold product including the date of purcha...

Page 18: ...use the sauna without supervision 5 Consult your doctor about any health concerns regarding sauna bathing 6 Consult child welfare clinic about taking little babies to the sauna 7 Always move carefull...

Page 19: ...n there are people nearby the steam coming off the heater is burning hot Do not throw too much water on to the heater Maximum amount is half a litre at a time Trouble shooting If the heater or sauna r...

Page 20: ...Instructions for installation and use IKI electric heaters with Finlandia control unit Page 20 Copyright IKI Kiuas Oy Pid t mme oikeudet muutoksiin...