11
3.
Make sure no controls or wires are interfering with the o-ring or the
back of the housing.
4.
Place each lid snap into the corresponding hook on the housing
back.
5.
Push the lid snaps towards the housing until they are flat against
the housing and the lock has engaged. Close opposing lid snaps at
the same time.
Even Gap on
All Sides
Housing Back
Main O-ring
Lid Snap
Lid Hook
6.
Check the o-ring seal. The o-ring should form a uniform, solid line
around the back of the housing. There will be a small, even gap
around the housing between the housing back and the housing
front.
Lens Port Options
5516.15 Dome Port (included with housing)
NOTE: This housing is compatible with DLM Port Systems ONLY.
Housing is NOT compatible with FL and DL Lens Port Systems.