13
6. COLOR GAIN: Adjust/set the color level of picture.
OFF: (No gain up the color level)/LOW/ MIDDLE/ HIGH
7. GAMMA: Adjust/set the Gamma correction value of picture
between 0.38 / 0.42 / 0.45 / 0.50 / 0.55 / 0.63 / 0.71 / 0.83 / 1.0.
Note : The lower value for GAMMA above, realize to display more
brighter for dark section of picture, but it cause noise level
up bit and reduce the graduation for bright section of picture.
4. CAMERA TITLE
Used to set the camera /site name, allows up to.52 alphanumeric (26
alphanumeric /1 line, 52 alphanumeric /2 line on screen).
OFF
: No display on screen.
ON
: Display on screen.
●
Setting TITLE
CAMERA TITLE : Set “ON” and press
“E” button for display right shown screen.
Select the needed character with L, R, U,
D button and press “E” button. And the
cursor for TITLE is stepped to next letter
position.
●
Erase 1 letter by 1 letter
Move the cursor with
←→
on erasing
needed letter and “CLR” + “E” button.
●
POSITION
Move the cursor on “POS” and press “E “button then Title displayed on
screen.
Set the Title display position with L, R, U, D button and determine press
“E”.
No display the TITLE on screen when set “OFF” for CAMERA TITLE.
5. D–ZOOM (Digital Zoom Up)
Set the Zoom up magnify power for center of picture.
OFF
: Inactivate D-Zoom function (same as with “ON” SET x1).
ON
:
D-Zoom functioned.
1. Set the magnify power between x1 to x32.
If “DIS” stabilizer (6-3-3 item3 page 22) is set ON, D-ZOOM is not functioned.
6. MOTION DET (MOTION DETECTION)
Detect the changing of picture (moving subject) function.
OFF
: Inactivate MOTION DET function.
ON
: MOTION DET functioned.
CAMERA TITLE
ABCDEFGHIJKLMNOPQRSTUV
WXYZ0123456789-! #$%&
()̲̀,¥:;<=>?@\^*.x+/
←→↑↓ CLR POS
RETURN
Summary of Contents for ICD 525
Page 30: ...MEMO ...
Page 31: ...MEMO ...