background image

12

13

Installation

/// Connection to the power supply

100 - 240 V ~

50/60 Hz

240 W

IP 21

1.

2.

!

 Notice!

The socket used must be earthed (fitted with earth contact)� 
Observe the ambient conditions (temperature, humidity etc�) listed under “Technical Data”�

Symbol

Designation

Function

Lock button symbol

Indicate the buttons are locked�

A

 (B / C)

Operating mode symbol

Indicate the device is in operating mode (A, B or C)�

INT

Intermittent mode symbol

Indicate the intermittent mode is activated�

USB connection symbol

Indicate the device is communicating via USB� 

Timer / Counter symbol
(Tempering)

Indicate the "Timer / Counter" start condition is set to: 
"Immediately" (see "Tempering" under "Timer")� 

Timer symbol
(Tempering)

Indicate the "Timer" start condition is set to: "Set 
temperature reached" (see "Tempering" under "Timer")� 

Counter symbol
(Tempering)

Indicate the "Counter" start condition is set to: 
"Set temperature reached" (see "Tempering" under 
"Timer")� 

Timer / Counter symbol
(Mixing)

Indicate the "Timer / Counter" for mixing�

Mixing symbol

Indicate the mixing function is activated�

00:10

 

Mixing in Intermittent 
mode symbol

Indicate the mixing function with intermittent mode is 
activated�

Tempering (heating) 
symbol

Indicate the heating function is activated�

Tempering (cooling) 
symbol

Indicate the cooling function is activated�

Fast

(Moderate /
Slow)

Temperatur control rate 
symbol

Indicate the tempering "Control rate" is set to "Fast 
(Moderate or Slow)"�

PC

PC control symbol

Indicate the device is controlled by a PC�

PR

Program control symbol

Indicate the device is in program control mode�

Power failure symbol

Indicate a previous power supply interruption�

IKA ThermoCover Symbol

Indicate IKA ThermoCover is attached to the device�

/// Explanation of symbols on the working screen

A

IKA MATRIX 2.0 mL

Fast    

         

actual ºC

Set ºC

Set rpm

actual rpm

25.0

100.0

300

300

0:00:00

0:00:00

0:10

PC

PC / PR

B / C

Note: 

The symbols displayed change depending on the status and settings of the device�

Summary of Contents for MATRIX ORBITAL DELTA PLUS

Page 1: ...IKA MATRIX ORBITAL DELTA PLUS...

Page 2: ...2 3 ENGLISH...

Page 3: ...rning symbols 6 Safety instructions 7 Unpacking 10 Operation 17 Intended use 9 Technical Data 38 Interfaces and outputs 31 Warranty 39 Maintenance and cleaning 37 Accessories 37 Operator panel and dis...

Page 4: ...arting up and follow the safety instructions Keep the operating instructions in a place where it can be accessed by everyone Ensure that only trained staff work with the device Follow the safety instr...

Page 5: ...foreign objects liquids and other contaminants Never use tubes made of glass or other fragile material Glass tubes can be smash Only use sealed micro test tube and sealed microplate deepwell plate Th...

Page 6: ...empering function E Timer button Enter the timer menu F Programs Prog button Enter the programs menu G Menu button Touch it once main menu is displayed Touch it a second time back to the working scree...

Page 7: ...temperature reached see Tempering under Timer Timer Counter symbol Mixing Indicate the Timer Counter for mixing Mixing symbol Indicate the mixing function is activated 00 10 Mixing in Intermittent mod...

Page 8: ...14 15 Inserting the deepwell plate DWP microplate MTP Inserting the micro test tubes Attaching the exchangeable attachments 1 2 1 2 1 Click 3 2 A B C D E F G H 1 2...

Page 9: ...een established with the device by pressing down the button the heating function can prevent the formation of condensate Operation Switching on IKA MATRIX ORBITAL Delta Version 1 02 003 1 01 021 Shake...

Page 10: ...tual rpm 25 1 0 300 0 00 00 0 00 01 38 0 LIMIT 1 0 LIMIT 100 0 0 00 00 99 59 59 25 0 38 0 max Setting the speed and starting mixing A IKA MATRIX 2 0 mL Fast actual C Set C Set rpm actual rpm 38 0 38 0...

Page 11: ...s 3 3 3 3 3 3 F F F F s s s s s s s s 2 2 2 Restarting the tempering and mixing function Note During the pause status the tempering mixing function can be switched off separately by touching temperin...

Page 12: ...0 mL Fast actual C Set C Set rpm actual rpm 38 0 38 0 500 500 0 00 39 0 00 50 A IKA MATRIX 2 0 mL Fast actual C Set C Set rpm actual rpm 38 0 500 0 00 40 0 00 51 38 0 500 Unlocking the buttons 1s A I...

Page 13: ...0 Fast 0 00 00 10 00 00 0 500 Quick mix Note When the tempering function is activated the Quick mix function is not available Press the Menu button G Select right menu item by touching the speed butt...

Page 14: ...ed and CW time Stop time is set Note CW time and Stop time can be set separately CCW 0 CW 300 rpm time 300 CCW Intermittent mode is activated and CCW time Stop time is set Note CCW time and Stop time...

Page 15: ...atically executed In control mode x x K The hysteresis tolerance of the actual temperature to target temperature is set e g 0 1 K The target values and settings of the segment are valid until the actu...

Page 16: ...t C or F for the temperature A check mark indicates the unit that is set for the system Display In the Background menu option you select black or white color for the working screen In the Firmware Upd...

Page 17: ...ed to the WD safety temperature limit value The error message Error 2 is displayed The above details correspond as far as possible to the recommendations of the NAMUR working party NAMUR recommendatio...

Page 18: ...ons between device and external devices PC 1 1 Cable This cable is required to connect RS 232 port to a PC 1 2 RxD 3 TxD 4 5 GND 6 7 RTS 8 CTS 9 1 RxD 2 TxD 3 4 GND 5 6 RTS 7 CTS 8 9 PC 1 2 3 4 5 6 7...

Page 19: ...r error code is displayed then take one of the following steps Contact the service department Send the device for repair including a short description of the fault Error 49 Motor hall sensor fault Err...

Page 20: ...e delivery invoice and giving reasons for the claim You will be liable for freight costs The warranty does not cover worn out parts nor does it apply to faults resulting from improper use insufficient...

Page 21: ...sales england ika com MALAYSIA IKA Works Asia Sdn Bhd Phone 60 3 6099 5666 eMail sales lab ika my CHINA IKA Works Guangzhou Phone 86 20 8222 6771 eMail info ika cn POLAND IKA Poland Sp z o o Phone 48...

Reviews: