Maintenance and cleaning
The device is maintenance-free� It is only subject to the natural wear and tear of components and
their statistical failure rate�
/// Cleaning
For cleaning disconnect the mains plug!
Use only cleaning agents which have been approved by IKA to clean the devices:
These are: water (containing surfactant) and isopropyl alcohol�
› Wear protective gloves during cleaning the devices�
› Electrical devices may not be placed in the cleansing agent for the purpose of cleaning�
› Do not allow moisture to get into the device when cleaning�
› Before using another than the recommended method for cleaning or decontamination, the
user must ascertain with that this method does not destroy the device�
/// Repairs
Please send in device for repair only after it has been cleaned and is free from any
materials which may constitute a health hazard.
For repair, please request the “Decontamination Certificate” from
IKA
, or download printout
of it from the
IKA
website
www.ika.com
�
If you require servicing, return the device in its original packaging� Storage packaging is not
sufficient� Please also use suitable transport packaging�
/// Ordering spare parts
When ordering spare parts, please indicate:
› Device type�
› Serial number, see type plate
› Item and designation of the spare part, see:
www.ika.com
, spare parts diagram and spare
parts list�
› Software version (Briefly visible in the display when the device is switched on)�
If the action described fails to resolve the fault or another error code is displayed then take
one of the following steps:
› Contact the service department
› Send the device for repair, including a short description of the fault�
Error 49 - Motor hall sensor fault
Error message
› Motor hall sensor signal lost
Effect
› Mixing function off
› Tempering function off
Solutions
› Switch off and restart the device�
› Send device for repair if the error message appear again�
Accessories
For accessiores see
www.ika.com
�
Exchangable attachments
Tubes / Plates
Max. Drehzahl
Max.
Temperature
Min.
Temperature
IKA MATRIX AUFSATZ 0�5 ML
24 x 0�5 ml
Gefäße
2000 rpm
100 °C
RT - 15 °C
IKA MATRIX AUFSATZ 1�5 ML
24
x 1�5 ml Gefäße
2000 rpm
100 °C
RT - 15 °C
IKA MATRIX AUFSATZ 12 MM
24
x 11 mm bis 11�9 mm
Gefäße
2000 rpm
100 °C
RT - 15 °C
IKA MATRIX AUFSATZ CRYO
24
x 1�5 ml oder 2�0 ml
Cryo-Gefäße
2000 rpm
100 °C
RT - 15 °C
IKA MATRIX AUFSATZ 2�0 ML
24
x 2�0 ml Gefäße
2000 rpm
100 °C
RT - 15 °C
IKA MATRIX AUFSATZ 5�0 ML
8
x 5�0 ml Gefäße
1000 rpm
100 °C
RT - 15 °C
IKA MATRIX AUFSATZ 15 ML
8
x 15 ml Gefäße
1000 rpm
100 °C
RT - 15 °C
IKA MATRIX AUFSATZ 50 ML
4
x 50 ml Gefäße
1000 rpm
100 °C
RT - 15 °C
IKA MATRIX AUFSATZ PCR 96
96
x 0�2 ml PCR-Gefäße
1
x 96-Well-PCR-Platten
2000 rpm
100 °C
RT - 15 °C
IKA MATRIX AUFSATZ PCR 384
1
x 384-Well-PCR-Platten
3000 rpm
100 °C
RT - 15 °C
IKA CARRIER
1 x MTP
1 x DWP
3000 rpm
2000 rpm
100 °C
RT - 15 °C
IKA Abdeckung
For IKA PCR 96, IKA PCR 384, IKA 0�5 ml, IKA 1�5 ml, IKA 2�0 ml and IKA CARRIER (MTP & DWP)�
Note:
For even tempering and to protect the samples from unwanted exposure to light�
IKA THERMOCOVER
For IKA PCR 96, IKA PCR 384, IKA 0�5 ml, IKA 1�5 ml, IKA 2�0 ml and IKA CARRIER (MTP & DWP)�
Note:
Prevent the formation of condensate on vessel walls or vessel lids�