27
NOTE:
After the power has failed, the set time is erased and the
device switches into Offline operating mode (standstill). The set speed
stays adjusted.
Control model
The target
speed and
upper speed
limit (max.
800 rpm) re-
quired for the
agitation pro-
cess can be set
with the aid of
the left turn
button and are
shown on the
right display.
Continuous
mode is activa-
ted by presing
the left turn button. If a target time is set in the right display in conti-
nuous mode or is saved from previous agitation processes, the agitati-
on process can be continued in continuous mode by pressing the right
turn button. The agitation process can be terminated by pressing the
left or the right turn button.
ATTENTION!
After a power failure, the device will not
automatically start up in operating mode
A
or
B
by itself.
In operating mode
C
, the device automatically starts up by
itself.
Control mode
The amount
of time requi-
red for the agi-
tation process
can be adjusted
with aid of the
right turn but-
ton and is
shown on the
right display.
If a target time
(max. 9 h
59 min) is set
in the right dis-
play or has
been saved from
previous
agitation processes, you can activate or terminate the agitation process
with the left turn button while setting the target speed.
You can exit timed mode and interrupt the agitation process by pres-
sing on the right turn button.
ATTENTION!
After a power failure, the device will not
automatically start up in operating mode
A
or
B
by itself.
In operating mode
C
, the device automatically starts up by
itself.
Basic model
You can adjusted the speed (max. 800 rpm) by turning the left turn
button. When you do this, you should note that the agitator does not
begin to run until continuous mode or time mode is active. For the user
this means that it is possible to set a speed in the Off operating mode
that will be required for continuous operation or for several agitation
processes in timed mode.
345
345
I
min
/
PV
PV
min
n
i
959
.
959
:
345
345
I
min
/
PV
PV
min
n
i
959
:
345
I
min
/
PV
PV
min
n
i
959
:
Time mode in mode of operation A
Continuos mode in mode of operation A
Display after power failure
in mode of operation A
Setting the speed
345
345
I
min
/
PV
PV
min
n
i
959
.
959
:
345
345
I
min
/
PV
PV
min
n
i
959
:
345
I
min
/
PV
PV
min
n
i
959
:
Time mode in mode of operation A
Continuos mode in mode of operation A
Display after power failure
in mode of operation A