IKA KS 130 basic Operating Instructions Manual Download Page 2

    2

You have purchased an laboratory machine which meets the highest 
engineering and quality standards.
In accordance with guarantee conditions, the guarantee period is 24 
months. For claims under the guarantee please contact your local dea-
ler. You may also send the machine direct to our works, enclosing the 
delivery invoice and giving reasons for the claim.  You will be liable for 
freight costs.
The warranty does not cover wearing parts, nor does it apply to faults 
resulting from improper use or insufficient care and maintenance con-
trary to the instructions in this operating manual.
If you require servicing, return the appliance in its original packaging. 
Storage packaging is not sufficient. Please also use suitable transport 
packaging.

Vous avez fait l’acquisition d’un appareil de laboratoire , qui répond aux 
exigences les plus élevées de technique et de qualité.
Conformément aux conditions de garantie, la durée de garantie s’élève 
à 24 mois. En cas de recours en garantie, veuillez vous adresser à votre 
fournisseur spécialisé. Vous pouvez également envoyer directement 
l’appareil à notre usine en joignant votre facture et l’exposé des motifs 
de réclamation. Les frais d’expédition sont à votre charge.
La garantie ne s’étend pas aux pièces d’usure et n’est pas valable en cas 
de défauts dus à une utilisation non conforme et un soin et un entretien 
insuffisants, allant à l’encontre des recommandations du présent mode 
d’emploi.
En cas de retour au service après vente, renvoyez l’appareil dans son 
emballage d’origine. Les emballages de stockage ne sont pas suffisants 
pour le renvoi. Utilisez un emballage de transport supplémentaire 
adapté.

Sie haben ein Laborgerät erworben, das in Technik und Qualität höchs-
ten Ansprüchen gerecht wird.
Entsprechend den Verkaufs- und Lieferbedingungen beträgt die 
Garantiezeit 24 Monate. Im Garantiefall wenden Sie sich bitte an Ihren 
Fachhändler. Sie können aber auch das Gerät unter Beifügung der 
Lieferrechnung und Nennung der Reklamations-gründe direkt an unser 
Werk senden. Frachtkosten gehen zu Ihren Lasten.

Die Garantie erstreckt sich nicht auf Verschleißteile und gilt nicht für 
Fehler, die auf unsachgemäße Handhabung und unzureichende Pflege 
und Wartung, entgegen den Anweisungen in dieser Betriebsanleitung, 
zurückzuführen sind.
Senden Sie im Servicefall das Gerät in der Originalverpackung 
zurück. Lagerverpackungen sind für den Rückversand nicht aus-
reichend. Verwenden Sie zusätzlich eine geeignete Transport- 
verpackung.

Gewährleistung

Warranty

Garantie

KONFORMITÄTSERKLÄRUNG  

DE

Wir erklären in alleiniger Verantwortung, dass dieses Produkt den Bestimmungen der 
Richtlinien 2006/42/EG, 2011/65/EU, 2014/30/EU und 2014/35/EU entspricht und mit 
den folgenden Normen und norminativen Dokumenten übereinstimmt:
EN 61010-1, EN 61010-2-051, EN 60529, EN 61326-1 und EN ISO 12100.

DECLARATION OF CONFORMITY   

EN

We declare under our sole responsibility that this product corrosponds to the regulations 
2006/42/EC, 2011/65/EU, 2014/30/EU and 2014/35/EU  and conforms with the stan-
dards or standardized documents EN 61010-1, EN 61010-2-051, EN 60529, EN 61326-1 
and EN ISO 12100.

DÉCLARATION DE CONFORMITÉ    

FR

Nous déclarons sous notre propre responsabilité que se produit est conforme aux régle-
mentations 2006/42/CE, 2011/65/UE, 2014/30/UE et 2014/35/UE et en conformité avec 
les normes ou documents normalisés suivant EN 61010-1, EN 61010-2-051, EN 60529, 
EN 61326-1 et EN ISO 12100.

Summary of Contents for KS 130 basic

Page 1: ...Betriebsanleitung DE 3 Operating instructions EN 19 Mode d emploi FR 35 IKA KS 130 basic IKA KS 130 control KS 130 basic KS 130 control 20000005491 KS_130_b c_022016...

Page 2: ...de transport suppl mentaire adapt Sie haben ein Laborger t erworben das in Technik und Qualit t h chs ten Anspr chen gerecht wird Entsprechend den Verkaufs und Lieferbedingungen betr gt die Garantiez...

Page 3: ...schriften f r den Einsatz im Labor Beim Transport des Ger tes ist das hohe Eigengewicht zu ber cksich tigen Es ist darauf zu achten dass beim Abstellen des Ger tes die Finger nicht gequetscht werden D...

Page 4: ...denen der Anwender Kenntnis dar ber hat dass der Energieeintrag durch das Sch tteln unbedenklich ist Das gleiche gilt auch f r den Energieeintrag durch Sonneneinstrahlung w hrend des Sch ttelvorgangs...

Page 5: ...ever sierbetrieb Rechts Linkslauf des Sch tteltisches ausgeliefert werden Der Reversierbetrieb kann jedoch nur ber die serielle Schnittstelle in Verbindung mit einem PC z B mit labworldsoft genutzt we...

Page 6: ...en rechten Drehknopf Dauerbetrieb Das Ger t unterbricht den Sch ttelvorgang nicht On LED leuchtet 6 Zeitbetrieb Das Ger t unterbricht nach Ablauf einer einge stellten Zeit max 50 min den Sch ttelvorga...

Page 7: ...h rt der Sch ttler auf zu sch tteln 7 Einstellen der Betriebsart nur Control Variante Die Control Ger tevariante kann in den nachfolgend beschriebenen Betriebsarten betrieben werden Betriebsart A Ab W...

Page 8: ...e Zeitsollwert z B 3 58 mit der Angabe h min und blinkendem SV angezeigt Am Stern im Display f r die Zeiteinstellung erkennt der Anwender da die Betriebsart B aktiv ist d Daraufhin wird in der linken...

Page 9: ...Drehknopfes kann der Sch ttler in Betrieb genommen werden Die Drehzahl und Zeitistwerte werden daraufhin gro auf dem Display angezeigt Au erdem wird statt SV der Text PV auf dem Display angezeigt Der...

Page 10: ...das Symbol angezeigt Ist das Symbol nicht im rechten Display zu sehen ist die Arretierfunktion des Sch tteltisches ausge schaltet ACHTUNG Nach einem Stromausfall f hrt der entriegelte frei bewegliche...

Page 11: ...org nge im Zeitbetrieb ben tigt HINWEIS Nach einem Stromausfall wird die eingestellte Zeit gel scht und das Ger t schaltet in den Off Betriebszustand Stillstand Die ein gestellte Drehzahl bleibt einge...

Page 12: ...higer Lauf des Ger tes bemerkt muss auf jeden Fall die Drehzahl soweit reduziert werden bis keine Laufunruhen mehr auftreten 12 Die von IKA empfohlenen Aufs tze m ssen auf dem Sch tteltisch gut befest...

Page 13: ...Einschalten des 4x blinken r teeinschaltroutine Ger tes mu gew hrlei 2 sec Pause Sicherheitsabfrage stet sein da der Motor nicht gew hrleistet keine Drehbewegung mehr ausf hrt Off LED rot Sicherheits...

Page 14: ...f LED rot Triac nicht ansteuerbar Interner Ger tefehler 8x blinken 2 sec Pause Fehlermeldung Control ACHTUNG Tritt eine Fehlermeldung auf wird ein akustisches Warnsignal erzeugt und auf dem Display an...

Page 15: ...ngen des NAMUR Arbeitskreises NAMUR Empfehlungen zur Ausf hrung von elekt rischen Steckverbindungen f r die analoge und digitale Signal bertragung an Labor MSR Einzelger ten Rev 1 1 bersicht der NAMUR...

Page 16: ...g der Rampenfunktio nen und L schen aller vorgege benen Rampensegmente RMP_LOOP_SET_X X 4 Arbeiten der Rampe in einer Schleife RMP_LOOP_RESET_X X 4 Beenden der Rampen Schleife IN_TYPE Anforderung der...

Page 17: ...r ck Lagerverpackungen sind f r den R ckversand nicht aus reichend Verwenden Sie zus tzlich eine geeignete Transportver packung PC 5 1 Adapter IKA Control Der Adapter PC 5 1 splittet die analogen und...

Page 18: ...te rechts 1 Schritt 1 min Zeitanzeige LCD Display max 9 h 59min Max Zeitabweichung 1 Schnittstelle RS 232 C Analog Technische nderung vorbehalten AS 130 1 Universalaufsatz AS 130 2 Halteklammeraufsatz...

Page 19: ...ins Covering or parts that are capable of being removed from the unit without accessory equipment have to be reattached to the unit for safe operation in order to prevent for example the ingress of fl...

Page 20: ...improper loading and the position of the center of gravity dynamic forces may arise during the agitation process that cause the shaker to move about on the table For limits on the load or the weight...

Page 21: ...ockwise motion for the vibration table on request However the reverse operation mode can only be used by means of the serial interface in combination with a PC for example with labworldsoft If the dev...

Page 22: ...setting Continuous operation The device does not interrupt the agi tation sequence On LED is lit Time operation The device interrupts the agitation pro cess after a set amount of time max 50 minutes...

Page 23: ...device type left display and operating mode right display are displayed for about 2 seconds c After this the set ore stored upper speed limit of the agitator is shown in the left display with SAFE the...

Page 24: ...for example 3 58 is shown in the right display with the indication h min and a flashing SV The user can recognize that operating mode B is active by the star in the display for the time setting d The...

Page 25: ...pressing the left or right turn button you can place the agitator in operation The speed and time values are then shown in large for mat on the display In addition the text PV is shown on the display...

Page 26: ...N After a power failure the unlocked freely movable agitation table will continue to perform a circular motion until the lock function can fasten the agitation table in place Basic model The amount of...

Page 27: ...lay or has been saved from previous agitation processes you can activate or terminate the agitation process with the left turn button while setting the target speed You can exit timed mode and interru...

Page 28: ...four lateral clamping screws on the agitation table AS 130 4 Reactant glass adapter For intensive agitation of tubes reactent bottles cuvettes and centri fuge tubes Clamping range from 10mm to 16mm f...

Page 29: ...e Off LED red The switch for the TIME Internal device error 6x flash function is not assigning 2 sec pause any target value Off LED red Problem with the power The device is beeing 7x flash supply oper...

Page 30: ...the watch tion in Mode 1 dog 30 KS 130 control version only The KS 130 control is equipped with a 15 pin SUB D connector on the rear side of the device The pins are assigned in operatin with analog a...

Page 31: ...for the design of electric plug connections for the analog and digital signal transmission to laboratory MSR individual units Rev 1 1 Overview of the NAMUR Instructions KS 130 control version only Abb...

Page 32: ...AME name Output of designation name max 6 characters default IKA _S_ OUT_WD1 m Watchdog mode 1 If the WD1 result occurs the agitation pro cess is turned off and Er2 is dis played The watchdog time is...

Page 33: ...stical failure rate When ordering spare parts please give the manufacturing number shown on the type plate the machine type and the name of the spare part Please send in equipment for repair only afte...

Page 34: ...igital Rotary knob on the front 1 step 1 rpm side right Time display LCD Display max 9 h 59min Max time deviation from idle 1 Interface RS 232 C analog Subject to technical changes AS 130 1 Universal...

Page 35: ...ernier ATTENTION Les couvercles et ou pi ces pouvant tre d tach es sans outil de l appareil doivent tre obligatoirement remis en place pour garantir un fon ctionnement s r de l appareil Ceci permet d...

Page 36: ...re uniforme sur la surface de la table Durant l agitation si le chargement et la position du centre de gravi t sont incorrects des forces dynamiques entra nent le d placement de l agitateur vibrant s...

Page 37: ...ependant seulement disponible via l interface s rielle en com binaison avec un PC par ex labworldsoft Si l appareil n est pas raccord une interface s rielle il se comporte comme un mod le control sans...

Page 38: ...en du bou ton de r glage de droite Mode continu L appareil n interrompt pas l agitation la DEL On est allum e Mode minuterie L appareil interrompt l agitation apr s coulement d une dur e de temps pr r...

Page 39: ...bascule les fonctions agitation et minute rie sont d senclench es Les valeurs de consigne s lectionn es sont m moris es et affich es de mani re digitale Elles sont reprises lors de l enclenchement de...

Page 40: ...a Tous les l ments d affichage des affichages digitaux sont activ s pendant environ 2 seconds b Affichage du type d appareil affichage de gauche et du mode de fonctionnement affichage de droite penda...

Page 41: ...on h min et SV Sur le dis play de gauche est afficha e la limite sup rieure de vitesse r gl e ou m moris e reprise du mode de fonctionnement A avec SAFE et OK pendant environ 2 secondes La limite sup...

Page 42: ...lage fonction Lock de la table vibrante peut tre activ d sactiv en fonction du r glage du signal acoustique de la minuterie Pour activer ou d sactiver le verrouillage les actions suivantes sont requis...

Page 43: ...ie et l agitation est arr t e ATTENTION Apr s une interruption de courant l appa reil ne red marre pas automatiquement sous le mode de fonctionnement A et B Apr s une interruption de courant l apparei...

Page 44: ...es ballons gradu s et des fioles d Erlenmeyer Equipement conseill maximal AS 2 1 Support pinces 12 12 Dimension lxhxp AS 2 2 Support pinces 8 9 en mm 44 AS 2 3 Support pinces 5 8 230 x 25 x 235 AS 2 4...

Page 45: ...s indiquer le code de panne affich Ceci facilitera l identification de la panne et permett ra un premier verdict Message de panne Panne Origine de panne DEL Off rouge Le potentiom tre pour le Modifica...

Page 46: ...de la fourchette du Panne interne l appareil capteur Er 9 Erreur d extraction des Logique BLP valeurs enregistr es Er 41 Triac d fectueux Panne interne l appareil Er 42 Relais de s curit d fec Panne i...

Page 47: ...es donn es et chaque r sponse s ach vent par CR LF Code hex 0x0D und 0x0A et comptent au maximum 80 caract res Les d cimales pr sentes dans un nombre virgule flottante sont s par es par un point Code...

Page 48: ...n rampe apr s RMP_PAUSE_X ant rieur RMP_RESET_X D sactivation des fonctions rampe et effacement de tous les seg ments rampe pr d finis RMP_LOOP_SET_X X 4 Positionnement des rampes dans une boucle RMP_...

Page 49: ...ntrol ne n cessite pas d entretien Il est simplement soumis au vieillissement naturel des pi ces et leur taux de d faillances statistique Lors de la commande de pi ces de rechange veuillez indiquer le...

Page 50: ...vibratoire amolitude approxima tivement circulaire Charge max kg 2 Dimensions B x T x H mm 270 x 98 x 316 Poids basic kg 7 7 Poids control kg 8 8 KS 130 basic R glage de la vitesse de rotation analog...

Page 51: ...51...

Page 52: ...3030800e IKA Werke GmbH Co KG Janke Kunkel Str 10 D 79219 Staufen Tel 49 7633 831 0 Fax 49 7633 831 98 sales ika de www ika com...

Reviews: