Please unpack the equipment carefully and check for any damages. It 
is important that any damages which may have arisen during transport 
are ascertained when unpacking. If applicable a fact report must be 
sent immediately (post, rail or forwarder).
The delivery scope covers:
A KS 130 basic or KS 130 control, for attachment screws, a single-head 
spanner, a connection cable and operating instructions.

With the purchase of this device, you have acquired a high-quality 
product. The design of the unit and its special shape ensure ease of 
handing and problem-free work. The materials used and an exact 
designation of them will significantly facilitate and simplify recycling 
and reuse of parts.
The speed-controlled external rotor asynchronous motor allows for 
infinitie speed adjustment in the range from 0 to 800 rpm. Electronic 
motor control holds the set speed constant even if the weight of the 
material on the surface increases. The heat given off by the motor can 
be used to heat up the holding surface for the agitation containers.
The Control variant of the device is equipped with a locking device. This 
makes it possible to fasten the agitation table in a defined position. By 
removing the rubber feet, the device can be connected or screwed in 
place in a defined position or with a system located next to it. Make 
certain that the maximum depth of 5 mm for inserting the screws is 
not exceeded. 
The Control variant of the device can be delivered with a reverse opera-
ting mode (clockwise / counterclockwise motion) for the vibration table 
on request. However, the reverse operation mode can only be used by 
means of the serial interface in combination with a PC (for example 
with labworld

soft

®

). If the device is not operated on a serial interface, 

it behaves like a Control device without reverse operation mode.

It is easy to exchange the various attachments.
The Control device variant is equipped with a serial interface that 
makes it possible to control the device through the PC (for example 
with labworld

soft

®

.

Check whether the voltage specified on the type plate matches the 
mains voltage available. The power socket used must be earthed 
(protective earth conductor contact). If these conditions are met, the 
device is ready to operate after plugging in the mains plug. If these 
procedures are not followed, safe operation cannot be guaranteed 
and/or the equipment may be damaged.

Observe the ambient conditions (temperature, humidity, etc.) listed 
under Technical Data.

When you turn on the basic device variant, the turn button for the time 
setting must be in the middle setting (not activated).

If the mounting surface is not even, you can improve the safety level 
of the device in reference to how it stands with the adjustable feet. To 
do this, turn the appropriate device foot downward with the wrench 
(included with delivery) until the device is standing securely on the 
surface.

To prevent the foot of the 
device from coming loose 
by itself, hold down the 
foot with one hand and 
tighten the oppsite hexa-
gonal nut with the 
other hand until it is finger 
tight.

Unpacking

Useful facts

Commissioning

IKA

R

1/min

min

Time

basic

HS 250

OFF

ON

10

5

15

Mot

60

30

90

25

20

30

35

45

40

50

210

120

150

180

270

240

300

A

Summary of Contents for KS 130 basic

Page 1: ...Betriebsanleitung DE 3 Operating instructions EN 19 Mode d emploi FR 35 IKA KS 130 basic IKA KS 130 control KS 130 basic KS 130 control 20000005491 KS_130_b c_022016...

Page 2: ...de transport suppl mentaire adapt Sie haben ein Laborger t erworben das in Technik und Qualit t h chs ten Anspr chen gerecht wird Entsprechend den Verkaufs und Lieferbedingungen betr gt die Garantiez...

Page 3: ...schriften f r den Einsatz im Labor Beim Transport des Ger tes ist das hohe Eigengewicht zu ber cksich tigen Es ist darauf zu achten dass beim Abstellen des Ger tes die Finger nicht gequetscht werden D...

Page 4: ...denen der Anwender Kenntnis dar ber hat dass der Energieeintrag durch das Sch tteln unbedenklich ist Das gleiche gilt auch f r den Energieeintrag durch Sonneneinstrahlung w hrend des Sch ttelvorgangs...

Page 5: ...ever sierbetrieb Rechts Linkslauf des Sch tteltisches ausgeliefert werden Der Reversierbetrieb kann jedoch nur ber die serielle Schnittstelle in Verbindung mit einem PC z B mit labworldsoft genutzt we...

Page 6: ...en rechten Drehknopf Dauerbetrieb Das Ger t unterbricht den Sch ttelvorgang nicht On LED leuchtet 6 Zeitbetrieb Das Ger t unterbricht nach Ablauf einer einge stellten Zeit max 50 min den Sch ttelvorga...

Page 7: ...h rt der Sch ttler auf zu sch tteln 7 Einstellen der Betriebsart nur Control Variante Die Control Ger tevariante kann in den nachfolgend beschriebenen Betriebsarten betrieben werden Betriebsart A Ab W...

Page 8: ...e Zeitsollwert z B 3 58 mit der Angabe h min und blinkendem SV angezeigt Am Stern im Display f r die Zeiteinstellung erkennt der Anwender da die Betriebsart B aktiv ist d Daraufhin wird in der linken...

Page 9: ...Drehknopfes kann der Sch ttler in Betrieb genommen werden Die Drehzahl und Zeitistwerte werden daraufhin gro auf dem Display angezeigt Au erdem wird statt SV der Text PV auf dem Display angezeigt Der...

Page 10: ...das Symbol angezeigt Ist das Symbol nicht im rechten Display zu sehen ist die Arretierfunktion des Sch tteltisches ausge schaltet ACHTUNG Nach einem Stromausfall f hrt der entriegelte frei bewegliche...

Page 11: ...org nge im Zeitbetrieb ben tigt HINWEIS Nach einem Stromausfall wird die eingestellte Zeit gel scht und das Ger t schaltet in den Off Betriebszustand Stillstand Die ein gestellte Drehzahl bleibt einge...

Page 12: ...higer Lauf des Ger tes bemerkt muss auf jeden Fall die Drehzahl soweit reduziert werden bis keine Laufunruhen mehr auftreten 12 Die von IKA empfohlenen Aufs tze m ssen auf dem Sch tteltisch gut befest...

Page 13: ...Einschalten des 4x blinken r teeinschaltroutine Ger tes mu gew hrlei 2 sec Pause Sicherheitsabfrage stet sein da der Motor nicht gew hrleistet keine Drehbewegung mehr ausf hrt Off LED rot Sicherheits...

Page 14: ...f LED rot Triac nicht ansteuerbar Interner Ger tefehler 8x blinken 2 sec Pause Fehlermeldung Control ACHTUNG Tritt eine Fehlermeldung auf wird ein akustisches Warnsignal erzeugt und auf dem Display an...

Page 15: ...ngen des NAMUR Arbeitskreises NAMUR Empfehlungen zur Ausf hrung von elekt rischen Steckverbindungen f r die analoge und digitale Signal bertragung an Labor MSR Einzelger ten Rev 1 1 bersicht der NAMUR...

Page 16: ...g der Rampenfunktio nen und L schen aller vorgege benen Rampensegmente RMP_LOOP_SET_X X 4 Arbeiten der Rampe in einer Schleife RMP_LOOP_RESET_X X 4 Beenden der Rampen Schleife IN_TYPE Anforderung der...

Page 17: ...r ck Lagerverpackungen sind f r den R ckversand nicht aus reichend Verwenden Sie zus tzlich eine geeignete Transportver packung PC 5 1 Adapter IKA Control Der Adapter PC 5 1 splittet die analogen und...

Page 18: ...te rechts 1 Schritt 1 min Zeitanzeige LCD Display max 9 h 59min Max Zeitabweichung 1 Schnittstelle RS 232 C Analog Technische nderung vorbehalten AS 130 1 Universalaufsatz AS 130 2 Halteklammeraufsatz...

Page 19: ...ins Covering or parts that are capable of being removed from the unit without accessory equipment have to be reattached to the unit for safe operation in order to prevent for example the ingress of fl...

Page 20: ...improper loading and the position of the center of gravity dynamic forces may arise during the agitation process that cause the shaker to move about on the table For limits on the load or the weight...

Page 21: ...ockwise motion for the vibration table on request However the reverse operation mode can only be used by means of the serial interface in combination with a PC for example with labworldsoft If the dev...

Page 22: ...setting Continuous operation The device does not interrupt the agi tation sequence On LED is lit Time operation The device interrupts the agitation pro cess after a set amount of time max 50 minutes...

Page 23: ...device type left display and operating mode right display are displayed for about 2 seconds c After this the set ore stored upper speed limit of the agitator is shown in the left display with SAFE the...

Page 24: ...for example 3 58 is shown in the right display with the indication h min and a flashing SV The user can recognize that operating mode B is active by the star in the display for the time setting d The...

Page 25: ...pressing the left or right turn button you can place the agitator in operation The speed and time values are then shown in large for mat on the display In addition the text PV is shown on the display...

Page 26: ...N After a power failure the unlocked freely movable agitation table will continue to perform a circular motion until the lock function can fasten the agitation table in place Basic model The amount of...

Page 27: ...lay or has been saved from previous agitation processes you can activate or terminate the agitation process with the left turn button while setting the target speed You can exit timed mode and interru...

Page 28: ...four lateral clamping screws on the agitation table AS 130 4 Reactant glass adapter For intensive agitation of tubes reactent bottles cuvettes and centri fuge tubes Clamping range from 10mm to 16mm f...

Page 29: ...e Off LED red The switch for the TIME Internal device error 6x flash function is not assigning 2 sec pause any target value Off LED red Problem with the power The device is beeing 7x flash supply oper...

Page 30: ...the watch tion in Mode 1 dog 30 KS 130 control version only The KS 130 control is equipped with a 15 pin SUB D connector on the rear side of the device The pins are assigned in operatin with analog a...

Page 31: ...for the design of electric plug connections for the analog and digital signal transmission to laboratory MSR individual units Rev 1 1 Overview of the NAMUR Instructions KS 130 control version only Abb...

Page 32: ...AME name Output of designation name max 6 characters default IKA _S_ OUT_WD1 m Watchdog mode 1 If the WD1 result occurs the agitation pro cess is turned off and Er2 is dis played The watchdog time is...

Page 33: ...stical failure rate When ordering spare parts please give the manufacturing number shown on the type plate the machine type and the name of the spare part Please send in equipment for repair only afte...

Page 34: ...igital Rotary knob on the front 1 step 1 rpm side right Time display LCD Display max 9 h 59min Max time deviation from idle 1 Interface RS 232 C analog Subject to technical changes AS 130 1 Universal...

Page 35: ...ernier ATTENTION Les couvercles et ou pi ces pouvant tre d tach es sans outil de l appareil doivent tre obligatoirement remis en place pour garantir un fon ctionnement s r de l appareil Ceci permet d...

Page 36: ...re uniforme sur la surface de la table Durant l agitation si le chargement et la position du centre de gravi t sont incorrects des forces dynamiques entra nent le d placement de l agitateur vibrant s...

Page 37: ...ependant seulement disponible via l interface s rielle en com binaison avec un PC par ex labworldsoft Si l appareil n est pas raccord une interface s rielle il se comporte comme un mod le control sans...

Page 38: ...en du bou ton de r glage de droite Mode continu L appareil n interrompt pas l agitation la DEL On est allum e Mode minuterie L appareil interrompt l agitation apr s coulement d une dur e de temps pr r...

Page 39: ...bascule les fonctions agitation et minute rie sont d senclench es Les valeurs de consigne s lectionn es sont m moris es et affich es de mani re digitale Elles sont reprises lors de l enclenchement de...

Page 40: ...a Tous les l ments d affichage des affichages digitaux sont activ s pendant environ 2 seconds b Affichage du type d appareil affichage de gauche et du mode de fonctionnement affichage de droite penda...

Page 41: ...on h min et SV Sur le dis play de gauche est afficha e la limite sup rieure de vitesse r gl e ou m moris e reprise du mode de fonctionnement A avec SAFE et OK pendant environ 2 secondes La limite sup...

Page 42: ...lage fonction Lock de la table vibrante peut tre activ d sactiv en fonction du r glage du signal acoustique de la minuterie Pour activer ou d sactiver le verrouillage les actions suivantes sont requis...

Page 43: ...ie et l agitation est arr t e ATTENTION Apr s une interruption de courant l appa reil ne red marre pas automatiquement sous le mode de fonctionnement A et B Apr s une interruption de courant l apparei...

Page 44: ...es ballons gradu s et des fioles d Erlenmeyer Equipement conseill maximal AS 2 1 Support pinces 12 12 Dimension lxhxp AS 2 2 Support pinces 8 9 en mm 44 AS 2 3 Support pinces 5 8 230 x 25 x 235 AS 2 4...

Page 45: ...s indiquer le code de panne affich Ceci facilitera l identification de la panne et permett ra un premier verdict Message de panne Panne Origine de panne DEL Off rouge Le potentiom tre pour le Modifica...

Page 46: ...de la fourchette du Panne interne l appareil capteur Er 9 Erreur d extraction des Logique BLP valeurs enregistr es Er 41 Triac d fectueux Panne interne l appareil Er 42 Relais de s curit d fec Panne i...

Page 47: ...es donn es et chaque r sponse s ach vent par CR LF Code hex 0x0D und 0x0A et comptent au maximum 80 caract res Les d cimales pr sentes dans un nombre virgule flottante sont s par es par un point Code...

Page 48: ...n rampe apr s RMP_PAUSE_X ant rieur RMP_RESET_X D sactivation des fonctions rampe et effacement de tous les seg ments rampe pr d finis RMP_LOOP_SET_X X 4 Positionnement des rampes dans une boucle RMP_...

Page 49: ...ntrol ne n cessite pas d entretien Il est simplement soumis au vieillissement naturel des pi ces et leur taux de d faillances statistique Lors de la commande de pi ces de rechange veuillez indiquer le...

Page 50: ...vibratoire amolitude approxima tivement circulaire Charge max kg 2 Dimensions B x T x H mm 270 x 98 x 316 Poids basic kg 7 7 Poids control kg 8 8 KS 130 basic R glage de la vitesse de rotation analog...

Page 51: ...51...

Page 52: ...3030800e IKA Werke GmbH Co KG Janke Kunkel Str 10 D 79219 Staufen Tel 49 7633 831 0 Fax 49 7633 831 98 sales ika de www ika com...

Reviews: